ASTM D5477-2011 Standard Practice for Identification of Polymer Layers or Inclusions by Fourier Transform Infrared Microspectroscopy (FT-IR)《使用傅里叶变换红外显微光谱(FTIR)识别聚合物层或夹杂物的标准操作规程》.pdf
《ASTM D5477-2011 Standard Practice for Identification of Polymer Layers or Inclusions by Fourier Transform Infrared Microspectroscopy (FT-IR)《使用傅里叶变换红外显微光谱(FTIR)识别聚合物层或夹杂物的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5477-2011 Standard Practice for Identification of Polymer Layers or Inclusions by Fourier Transform Infrared Microspectroscopy (FT-IR)《使用傅里叶变换红外显微光谱(FTIR)识别聚合物层或夹杂物的标准操作规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5477 11Standard Practice forIdentification of Polymer Layers or Inclusions by FourierTransform Infrared Microspectroscopy (FT-IR)1This standard is issued under the fixed designation D5477; the number immediately following the designation indicates the year oforiginal adoption or, in th
2、e case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes the techniques used for detectingtwo different polymer entitie
3、s as follows:1.1.1 Abnormal specks or spots on a surface or in the filmthat are objectionable as defects and1.1.2 Layers of different polymeric sheets commonly usedas barrier films made by coextrusion.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parenthese
4、s are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations pr
5、ior to use. Specific hazardstatements are given in Section 7.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD1248 Specification for Polyethylene Plastics ExtrusionMaterials for Wire and CableD1600 Terminology fo
6、r Abbreviated Terms Relating toPlasticsE131 Terminology Relating to Molecular SpectroscopyE168 Practices for General Techniques of Infrared Quanti-tative AnalysisIEEE/ASTM SI-10 Standard for Use of the InternationalSystem of Units (SI):The Modern Metric System3. Terminology3.1 Definitions:3.1.1 For
7、definitions of some of the terms used in thispractice, refer to Terminologies D883 and D1600.3.1.2 For units, symbols, and abbreviations used in thispractice, refer to Terminology E131 or IEEE/ASTM SI-10.4. Significance and Use4.1 Aspeck will ultimately cause a failure to occur by virtueof its appea
8、rance in a film or by the decrease in electrical ormechanical properties in the polymer substrate (see Specifica-tion D1248).4.2 The analysis of composite layers for barrier purposes bymicroscopic Fourier transform infrared spectroscopy (FT-IR)can indicate the adequacy of the barrier tape or indicat
9、e why abarrier may be defective (a missing layer or hole in the layer orpoor coextrusion practice). Fig. 1 represents a typical multi-layer film.5. Apparatus5.1 FT-IR Spectrophotometer, with nominal 4-cm1resolu-tion (see Practices E168).5.2 Microsampling Accessory, accommodated into theFT-IR for mic
10、roscopic infrared and visible light analysis, withnominal 6.25-m resolution on the infrared mode.35.3 Optical Microscope, equipped with cross-polarized lightand phase contrast accessories.5.4 Hot-Stage, which is accommodated into the opticalmicroscope.5.5 Microtome.5.6 SurlynTMIonomer, 1.25-mm thick
11、.45.7 Cyano-Acrylate Adhesive.5.8 Micrometer, capable of measuring to 60.0025 mm(0.0001 in., 0.1 mil).6. Material6.1 Cyano-Acrylate Adhesive.7. Hazards7.1 Use gloves when plaques are prepared using a heatedpress. Take care to avoid burns when handling microscopicslides with the hot plate.1This pract
12、ice is under the jurisdiction ofASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.70 on Analytical Methods.Current edition approved Dec. 1, 2011. Published December 2011. Originallypublished as D5477 93. Last previous edition approved in 2002 as D5477 02,which was wi
13、thdrawn in January 2011 and reinstated in December 2011. DOI:10.1520/D5477-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page on
14、the ASTM website.3Perkin Elmer Spectrum Spotlight 300 IR Imaging System.4Metal salt of carboxylated polyethylene.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.2 The optical bench of the FT-IR spectrophotometercontains a laser. To
15、 avoid eye injury, do not stare directly intothe laser beam.7.3 The cyano-acrylate adhesive will attach itself to thefingers and skin. Be careful to prevent this from occurring.8. Specimen Preparation8.1 It is necessary to microtome a thin cross section at rightangles to the surface of the film in o
16、rder to prepare theindividual layers for convenient observation.8.2 Packages that do not deflect during sectioning can bemicrotomed into the required thin sections as received. Flex-ible packages must be supported during sectioning. The sup-port technique that is used for flexible packages is shown
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD54772011STANDARDPRACTICEFORIDENTIFICATIONOFPOLYMERLAYERSORINCLUSIONSBYFOURIERTRANSFORMINFRAREDMICROSPECTROSCOPYFTIR

链接地址:http://www.mydoc123.com/p-519908.html