《ASTM D5399-2009(2017) Standard Test Method for Boiling Point Distribution of Hydrocarbon Solvents by Gas Chromatography《气相色谱法测定烃类溶剂沸点分布的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5399-2009(2017) Standard Test Method for Boiling Point Distribution of Hydrocarbon Solvents by Gas Chromatography《气相色谱法测定烃类溶剂沸点分布的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5399 09 (Reapproved 2017)Standard Test Method forBoiling Point Distribution of Hydrocarbon Solvents by GasChromatography1This standard is issued under the fixed designation D5399; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the boilingpoint distribution of hydrocarbon solve
3、nts by capillary gaschromatography. This test method is limited to samples havinga minimum initial boiling point of 37C (99F), a maximumfinal boiling point of 285C (545F), and a boiling range of 5to 150C (9 to 270F) as measured by this test method.1.2 For purposes of determining conformance of an ob
4、-served or calculated value using this test method to relevantspecifications, test result(s) shall be rounded off “to the nearestunit” in the last right-hand digit used in expressing thespecification limit, in accordance with the rounding-off methodof Practice E29.1.3 The values stated in SI units a
5、re standard. The valuesgiven in parentheses are for information purposes only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental pra
6、ctices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides a
7、nd Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D86 Test Method for Distillation of Petroleum Products andLiquid Fuels at Atmospheric PressureD850 Test Method for Distillation of Industrial AromaticHydro
8、carbons and Related MaterialsD1078 Test Method for Distillation Range of Volatile Or-ganic LiquidsD2887 Test Method for Boiling Range Distribution of Pe-troleum Fractions by Gas ChromatographyD2892 Test Method for Distillation of Crude Petroleum(15-Theoretical Plate Column)D3710 Test Method for Boil
9、ing Range Distribution of Gaso-line and Gasoline Fractions by Gas Chromatography(Withdrawn 2014)3E29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Termin
10、ology3.1 Definitions:3.1.1 initial boiling point (IBP), nthe point at which acumulative area count equal to 0.5 % of the total area under thechromatogram is obtained.3.1.2 final boiling point (FBP), nthe point at which acumulative area count equal to 99.5 % of the total area underthe chromatogram is
11、 obtained.4. Summary of Test Method4.1 The sample is introduced into a capillary gas chromato-graphic column that separates hydrocarbons in the order ofincreasing boiling point. The column temperature is raised at areproducible rate and the area under the chromatogram isrecorded throughout the run.
12、Boiling points are assigned froma calibration curve obtained under the same conditions byrunning a known mixture of hydrocarbons covering the boilingrange expected in the sample. From these data, the boilingpoint distribution of the sample is obtained.5. Significance and Use5.1 The gas chromatograph
13、ic determination of the boilingpoint distribution of hydrocarbon solvents can be used as an1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.35 on Solvents, Plasticizers, and
14、 Chemical Intermediates.Current edition approved Dec. 1, 2017. Published December 2017. Originallyapproved in 1993. Last previous edition approved in 2009 as D5399 09. DOI:10.1520/D5399-09R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at ser
15、viceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
16、PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization
17、 Technical Barriers to Trade (TBT) Committee.1alternative to conventional distillation methods for control ofsolvents quality during manufacture, and specification testing.5.2 Boiling point distribution data can be used to monitorthe presence of product contaminants and compositional varia-tion duri
18、ng the manufacture of hydrocarbon solvents.5.3 Boiling point distribution data obtained by this testmethod are not equivalent to those obtained by Test MethodsD86, D850, D1078, D2887, D2892, and D3710.6. Apparatus6.1 ChromatographAny gas chromatograph that canhandle capillary column and has the foll
19、owing characteristics:6.1.1 DetectorA flame ionization detector (FID) capableof continuous operation at a temperature equivalent to themaximum column temperature employed.6.1.2 Column Temperature ProgrammerThe chromato-graph must be capable of reproducible linear temperatureprogramming over a range
20、sufficient to establish a retentiontime of 1 min for n-pentane and to allow elution of entiresample within a reasonable time period.6.1.3 Sample Inlet SystemThe sample inlet system mustbe capable of operating continuously at a temperature up to themaximum column temperature employed, or provide on-c
21、olumn injection.NOTE 1The use of cool, on-column injection using an automaticinjector or sampler has been shown to provide better precision relative tomanual injection.6.1.4 ColumnA10 to 30 m by 0.53 mm inside diameter by3-m bonded methyl silicone, fused silica, or equivalentcolumn that elutes compo
22、nents in order of boiling points, andmeets the resolution criteria specified in 8.2 must be used (see8.4).6.1.5 IntegratorMeans must be provided for determiningthe accumulated area under the chromatogram. This can bedone by means of a computer or electronic integrator. A timingdevice can be used to
23、record the area at set time intervals. Thesame basis for measuring time must be used to determine theretention times in the calibration, and the sample. The maxi-mum signal measured must be within the linear range of themeasuring system used.6.1.6 Flow ControllerThe chromatograph must beequipped wit
24、h a constant-flow device capable of maintainingthe carrier gas at a constant flow rate throughout the tempera-ture program.6.1.7 Sample IntroductionA microsyringe is required forthe introduction of the sample to the gas chromatograph (seeNote 1).7. Reagents and Materials7.1 Purity of ReagentsReagent
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD539920092017STANDARDTESTMETHODFORBOILINGPOINTDISTRIBUTIONOFHYDROCARBONSOLVENTSBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-519681.html