ASTM D5375 D5375M-1998(2011) Standard Test Methods for Liner Removal at High Speeds from Pressure-Sensitive Label Stock《从压敏标签材料上高速去除衬里的标准试验方法》.pdf
《ASTM D5375 D5375M-1998(2011) Standard Test Methods for Liner Removal at High Speeds from Pressure-Sensitive Label Stock《从压敏标签材料上高速去除衬里的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5375 D5375M-1998(2011) Standard Test Methods for Liner Removal at High Speeds from Pressure-Sensitive Label Stock《从压敏标签材料上高速去除衬里的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5375/D5375M 98 (Reapproved 2011)Standard Test Methods forLiner Removal at High Speeds from Pressure-SensitiveLabel Stock1This standard is issued under the fixed designation D5375/D5375M; the number immediately following the designation indicates theyear of original adoption or, in the
2、case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the measurement of theadherence of the release liner to the adh
3、esive of a pressure-sensitive adhesive label.1.2 These test methods provide means of assessing theuniformity of the adhesion to the liner of a given type ofpressure-sensitive label. The assessment may be within a sheetor roll between sheets or rolls or between production lots.1.3 Variation in the la
4、bel backing, liner, liner release coat-ing, adhesive, and adhesive coating weight, affect the response.Therefore, these methods cannot be used to pinpoint thespecific cause(s) of nonuniformity.1.4 These test methods may not be appropriate to test labelshaving either relatively stiff backings or stif
5、f liners, or backingsshowing high stretch at low forces. These characteristics willresult in a high variability of the test response that is not a trueindication of the real nature of the adhesive bond.1.5 The values stated in either SI or inch-pound units are tobe regarded separately as standard. T
6、he values stated in eachsystem may not be exact equivalents; therefore, each systemmust be used independently, without combining values in anyway.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this stan
7、dard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D996 Terminology of Packaging and Distribution Environ-mentsD3715/D3715M Practice for Quality Assurance ofPressure-Sensitive T
8、apesD4332 Practice for Conditioning Containers, Packages, orPackaging Components for TestingE122 Practice for Calculating Sample Size to Estimate,With Specified Precision, the Average for a Characteristicof a Lot or Process3. Terminology3.1 Definitions:3.1.1 General definitions for packaging and dis
9、tributionenvironments are in accordance with Terminology D996.3.2 Definitions of Terms Specific to This Standard:3.2.1 pressure-sensitive labelthe combination of face ma-terial, pressure-sensitive adhesive, and liner.3.2.1.1 DiscussionThe adhesive is permanently tacky andinstantly adheres to whateve
10、r surface the label is designed for.Also, defined as a self-adhering label.4. Summary of Test Methods4.1 Test Method A The label stock is adhered to a rigidplatform with double-coated tape with the liner side up. Theliner is peeled from the adhesive at a specific rate. The liner ispeeled back over i
11、tself at 180 angle.4.2 Test Method B The label stock is adhered to a rigidplatform with double-coated tape with the liner side up. Theliner is peeled from the adhesive at a specified rate. The lineris peeled from the label stock at an angle of 90 to the stock.5. Significance and Use5.1 These test me
12、thods are a tool for development andquality assurance use. Given a specific pressure-sensitive labeland liner and a requirement in terms of the minimum formaximum peel value expected for this liner removal from thelabel, the data from the test can be used in conjunction withacceptance criteria.6. Ap
13、paratus6.1 Specimen Cutter The specimen cutter shall hold twosingle-edged razor blades in parallel planes, a precise distanceapart, to form a cutter of exact specimen widths. Two cutters,1These test methods are under the jurisdiction of ASTM Committee D10 onPackaging and are the direct responsibilit
14、y of Subcommittee D10.14 on Tape andLabels.Current edition approved April 1, 2011. Published April 2011. Originallyapproved in 1993. Last previous edition approved in 2004 as D5375/D5375M 98(2004). DOI: 10.1520/D5375_D5375M-98R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org,
15、orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.12.7 and 25.4-mm
16、 or 0.5 and 1-in. cutting width, shall beavailable. (See Fig. 1.)NOTE 1The 12.7-mm or 0.5 in. cutter shall consist of a 0.5 in. thickby 200 mm or 8 in. length of aluminum bar stock 12.7-mm or 0.5 in. wide.The edges for about 125 mm or 5 in. from one end shall be roundedslightly to form a handle. The
17、 width of the bar for 75 mm or 3 in. from theopposite end shall be narrowed to exactly 12.7 mm or 0.500 in. minus thethickness of a single razor blade (one or two used as cutting edges). Therazor blades shall be held in position using side plates. The end of thecutter shall be cut away at a 45 angle
18、 to expose the cutting edge at oneend of the blades. The edges shall be separated by 12.7 mm 6 0.127 mmor 0.500 6 0.005 in. A 25.4-mm or 1 in. cutter shall follow the samedescription, except that the barstock width shall be 25.4 mm or 1 in. andshall be narrowed to exactly 25.4 mm or 1.00 in. minus t
19、he thickness ofa single razor blade.6.2 Roller,3mechanically operated:6.2.1 A steel roller, 82 6 2.5 mm or 3.25 6 0.1 in. indiameter and 35 6 1.5 mm or 1.75 6 0.05 in. in width, coveredwith rubber approximately 6.35 mm or 0.25 in. in thickness,having a Shore Scale A durometer hardness of 80 6 5. The
20、surface of the roller shall be a true cylinder void of any concaveor convex deviations. The mass of the roller shall be 2040 6 45gor4.56 0.1 lb.6.2.2 No part of the apparatus shall increase the mass of theroller during use. The roller shall move mechanically at the rateof 5.0 6 0.2 mm/s or 12.0 6 0.
21、5 in./min.NOTE 2A simple check to determine if the rubber surface is cylindri-cal is to wrap the roller in a very thin paper (onion skin) and drag it acrossa flat glass plate on which is placed a carbon paper, face up. The carbonrubs off onto the thin paper wrapper to reveal high spots or hollows on
22、 therubber surface.6.3 Adhesion Tester4An adhesion tester that has a mov-able platform or clamp for holding the test panel specimen anda means of moving the panel parallel with the direction of thestressing clamp so that the specimen is held either in the sameplane or perpendicular to the stressing
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD5375D5375M19982011STANDARDTESTMETHODSFORLINERREMOVALATHIGHSPEEDSFROMPRESSURESENSITIVELABELSTOCK

链接地址:http://www.mydoc123.com/p-519622.html