ASTM D5374-1993(2005) Standard Test Methods for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation《电绝缘评定用实验室强制对流炉的标准试验方法》.pdf
《ASTM D5374-1993(2005) Standard Test Methods for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation《电绝缘评定用实验室强制对流炉的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5374-1993(2005) Standard Test Methods for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation《电绝缘评定用实验室强制对流炉的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5374 93 (Reapproved 2005)An American National StandardStandard Test Methods forForced-Convection Laboratory Ovens for Evaluation ofElectrical Insulation1This standard is issued under the fixed designation D 5374; the number immediately following the designation indicates the year ofor
2、iginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover procedures for evaluating thecharac
3、teristics of forced-convection ventilated electrically-heated ovens, operating over all or part of the temperaturerange from 20C above the ambient temperature to 500C andused for thermal endurance evaluation of electrical insulatingmaterials.1.2 These test methods are based on IEC Publication 216-4-
4、1, and are technically identical to it. This compilation of testmethods and an associated specification, D 5423, have re-placed Specification D 2436.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this s
5、tandard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 2436 Specification for Forced-Convection LaboratoryOvens for Electrical InsulationD 5423 Specification for Forced-Convect
6、ion LaboratoryOvens for Evaluation of Electrical Insulation2.2 Other Document:IEC Publication 216-4-1 Guide for the Determination ofThermal Endurance Properties of Electrical InsulatingMaterials, Part 4Aging Ovens, Section 1Single-Chamber Ovens33. Terminology3.1 Refer to the terminology section of S
7、pecificationD 5423.4. Significance and Use4.1 It is essential that ovens used for thermal evaluation ofinsulating materials be capable of maintaining uniform condi-tions of temperature and air circulation over the extendedperiods of time that are required for conducting these tests.Specification D 5
8、423 specifies the permissible deviations fromabsolute uniformity that have been generally accepted interna-tionally for these ovens. These test methods include proceduresfor measuring these deviations and other specified character-istics of the ovens.5. Apparatus5.1 Multi-Point Recording Potentiomet
9、er, having provisionsfor at least nine iron-constantan or chromel-alumel thermo-couples, with scale readings to 0.1C or less. Use of a dataprocessor or a data logger may be helpful in reducing thenumber of calculations required.5.2 Calibrated Iron-Constantan or Chromel-Alumel Ther-mocouples, using 0
10、.5-mm diameter or smaller wire and havinga junction size not over 2.5 mm long. If calibrated thermo-couples are not available, thermocouples made from a singlespool of thermocouple wire may be used provided that, whenplaced within 10 mm of each other without touching in an ovenchamber at 200C, they
11、give values for temperature that do notdiffer from each other by more than 0.2C.5.3 A temperature measuring system other than thermo-couples and a potentiometer may be used, provided that thesensitivity, accuracy, and response time are at least equivalentto that of the equipment described above, and
12、 that the objec-tives of 6.2.3 relative to minimization of heat conductioneffects can be met.5.4 Thermal Lag Time Specimen, consisting of a solid brasscylinder, 10 mm in diameter and 55 mm long, with onejunction of a differential thermocouple soldered to the surfacemidway between the ends. The other
13、 junction of the thermo-couple must be capable of being moved at least 80 mm awayfrom the brass cylinder. An appropriate temperature indicator(as in 5.1, or other) must be provided for indication oftemperature differences to the nearest 0.1C as measured by thedifferential thermocouple.5.5 Watt-Hour
14、Meter, of the appropriate voltage and phase,capable of reading to the nearest 1.0 Wh or less.1These test methods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are the direct responsibility ofSubcommittee D09.17 on Thermal Characteristics.Curren
15、t edition approved Sept. 1, 2005. Published October 2005. Originallyapproved in 1993. Last previous edition approved in 1999 as D 5374 93 (1999).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards
16、volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United S
17、tates.6. Procedures6.1 Rate of Ventilation:6.1.1 Summary of Test MethodThe rate of ventilation iscalculated using determinations of (1) the average powerrequired to maintain the oven at a given temperature with itsports open and (2) the average power required to maintain theoven at the same temperat
18、ure with its ports closed. The test isconducted at 100C and at the maximum temperature at whichthe oven may be used.6.1.2 Seal all openings into the oven, including, but notnecessarily limited to, the vent ports, door, thermometer ports,and the space around the blower shaft (if the blower motor ismo
19、unted externally).6.1.3 Install a watt-hour meter, as described in 5.5,intheoven electrical supply line.6.1.4 Install a temperature sensor, such as a thermometer, 2m to 3 m away from the oven, at least 1 m away from any solidobject, and approximately level with the oven air intake. Usethe oven tempe
20、rature indicator to measure the internal tem-perature of the oven.6.1.5 Raise the oven temperature to 100 6 2C. When thetemperature of the oven has stabilized, measure the consump-tion of power over a measured period of 30 to 40 min. Beginand end the measuring period at corresponding points of thecy
21、clic temperature fluctuation; for example, the moment whenthe heaters are switched on by the thermostat in the case of an“on/off” control. Measure and record the room temperature,which must not vary by more than 2C during the test.6.1.6 Remove the seals to restore the oven to its normaloperating con
22、dition. If necessary, adjust the vents and dampersto positions estimated to provide the specified rate of ventila-tion.6.1.7 Repeat 6.1.5. The average ambient air temperaturemust be within 2C of the average ambient temperaturemeasured in 6.1.5.6.1.8 Calculate the rate of ventilation in the oven usin
23、g thefollowing equation:N 5 3.59 P22 P1!/VrDT! (1)where:N = number of air changes per hour,P1= average power consumption, with no ventilation,obtained by dividing the energy consumption deter-mined from the watt-hour meter readings by theduration of the test in hours, W,P2= average power consumption
24、 during ventilation, cal-culated in the same manner, W,V = total volume of air circulated within the oven, m3(seeNote 1),r = density of the ambient room air during the test,kg/m3(see Note 2), andDT = difference in temperature between the oven and theambient room temperature, C.NOTE 1This volume incl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD537419932005STANDARDTESTMETHODSFORFORCEDCONVECTIONLABORATORYOVENSFOREVALUATIONOFELECTRICALINSULATION

链接地址:http://www.mydoc123.com/p-519619.html