ASTM D5303-1992(2007) Standard Test Method for Trace Carbonyl Sulfide in Propylene by Gas Chromatography《气相色谱法丙烯中微量硫化碳的标准试验方法》.pdf
《ASTM D5303-1992(2007) Standard Test Method for Trace Carbonyl Sulfide in Propylene by Gas Chromatography《气相色谱法丙烯中微量硫化碳的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5303-1992(2007) Standard Test Method for Trace Carbonyl Sulfide in Propylene by Gas Chromatography《气相色谱法丙烯中微量硫化碳的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5303 92 (Reapproved 2007)An American National StandardStandard Test Method forTrace Carbonyl Sulfide in Propylene by GasChromatography1This standard is issued under the fixed designation D 5303; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of traces ofcarbonyl sulfide (COS) i
3、n propylene. It is applicable to COSconcentrations from 0.5 to 4.0 mg/kg (parts per million bymass). See Note 1.NOTE 1The lower limit of this test method is believed to be below 0.1mg/kg, depending on sample size and sensitivity of the instrumentationbeing used. However, the cooperative testing prog
4、ram was conducted inthe 0.5 to 4.0 range due to limitations in preparing commercial testmixtures.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any
5、, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardsstatements are given in Section 8.2. Referenced Documents2.1 ASTM Standards:2
6、D 3609 Practice for Calibration Techniques Using Perme-ation TubesD 4468 Test Method for Total Sulfur in Gaseous Fuels byHydrogenolysis and Rateometric ColorimetryE 840 Practice for Using Flame Photometric Detectors inGas Chromatography3. Summary of Test Method3.1 A procedure is given for removing a
7、 sample from thesample cylinder, separating COS from propylene, detectingCOS, calibrating the detector, quantitating COS content in thesample, and assaying the gas standard. General comments andrecommended techniques are given.3.2 Arelatively large volume of sample is injected into a gaschromatograp
8、h having a single packed column, operated iso-thermally at 10 to 50C, that separates COS from propylene.COS is detected with a flame photometric detector.3.3 Calibration data, based on peak areas, are obtained usinga known gas standard blend of COS in the range expected forthe sample. The COS peak a
9、rea in the sample is measured andthe concentration of COS calculated.3.4 The COS gas standard blend is assayed prior to use forcalibration.4. Significance and Use4.1 In processes producing propylene, COS usually remainswith the C3hydrocarbons and must be removed, since it affectsproduct quality. COS
10、 acts as a poison to commercial polymer-ization catalysts, resulting in deactivation and costly processdowntime.4.2 Accurate gas chromatographic determination of traceCOS in propylene involves unique analytical problems becauseof the chemical nature of COS and idiosyncracies of trace levelanalyses.
11、These problems result from the reactive and absorp-tive nature of COS, the low concentration levels being mea-sured, the type of detector needed, and the interferences fromthe propylene sample matrix. This test method addresses theseanalytical problems and ways to properly handle them to assureaccur
12、ate and precise analyses.4.3 This test method provides a basis for agreement betweentwo laboratories when the determination of trace COS inpropylene is important. The test method permits severalcalibration techniques. For best agreement between two labs, itis recommended that they use the same calib
13、ration technique.5. Interferences5.1 Hydrogen sulfide (H2S) or sulfur dioxide (SO2) can bepresent in the propylene and must be separated from COS. (SeeNote 2.)NOTE 2H2S and SO2are separated from COS with the CarbopackBHT 100 columns or with the Chromosil 300 column.1This test method is under the jur
14、isdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.D0.03 on Propylene.Current edition approved Nov. 1, 2007. Published January 2008. Originallyapproved in 1992. Last previous edition approved in 2002 as D 530392(2002)e1.2For refere
15、nced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
16、Conshohocken, PA 19428-2959, United States.6. Apparatus6.1 Gas ChromatographAny gas chromatograph (GC)equipped with a flame photometric detector/electrometer sys-tem (FPD), as described in 6.2, may be used. A GC/FPDequipped with an output signal linearizer is also permitted.6.2 Detector System, flam
17、e photometric detector, eithersingle or dual burner design. Noise level must be no more thanone recorder chart division (see 6.5). The signal for COS mustbe at least twice the noise level at the 0.1 mg/kg level. Adiscussion of this detector is presented in Practice E 840. Theelectrometer used with t
18、he detector must have a sensitivity of1012A full scale ona1mVrecorder to achieve optimumdetectability at lowest levels.6.3 ColumnAny column that will effect the completeseparation of COS from propylene and other compoundsnormally present in propylene concentrates, and that is suffi-ciently inert to
19、preclude the loss of COS, may be used.Columns that meet these criteria, and that were used in thecooperative study for this test method, are listed in Table 1.6.4 Sample Inlet SystemAny gas sampling valve or gastight syringe that will permit introduction of up to 5.0 mLto thecolumn, and that will no
20、t cause any loss of COS, is suitable.6.5 RecorderAny strip chart recorder with a full scalerange of 1 mV, a maximum full scale balance time of 2 s, anda minimum chart speed of 0.5 cm/s, may be used.6.6 Data Handling SystemAny commercially availableGC integrator or GC computer system capable of accur
21、atelyintegrating the area (uVs) of the COS peak is satisfactory. Datasystems that will linearize the logarithmic output of the FPDare also satisfactory.6.7 Sample Cylinders, 300 mL capacity or larger, fluorocar-bon lined stainless steel, Type DOT 3E, 12409 kPa (1800 psi)working pressure.7. Reagents
22、and Materials7.1 Air, zero grade.7.2 Carbonyl sulfide (COS), lecture bottle, 97.5 % min.(WarningToxic! See Section 8, Hazards.)7.3 Gas Calibration Blends, 1 to 10 mg/kg COS in eithernitrogen, argon, propylene or a propylene/argon mixture. Theycan be obtained from any commercial supplier or prepared
23、asshown in Appendix X1 or Test Method D 4468.7.4 Gas Sampling Syringe, 0.1, 1.0, and 5.0 mL.7.5 Gas Sampling Valve and Sample Loops, fluorocarbon or316 stainless steel. See Footnote B of Table 1.7.6 Glass Vials, 125 cm.7.7 Hydrogen, pure grade, 99.9 %.7.8 Isooctane (2,2,4-trimethylpentane), sulfur f
24、ree, mini-mum purity 99 mol %. (WarningFlammable! Health Haz-ard.)7.9 Nitrogen or Helium, 99.999 % min.7.10 TFE-fluorocarbon septa and aluminum seals for vials.8. Hazards8.1 Carbonyl sulfide is toxic and narcotic in high concen-trations, and upon decomposition can liberate hydrogen sulfide.Exposure
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD530319922007STANDARDTESTMETHODFORTRACECARBONYLSULFIDEINPROPYLENEBYGASCHROMATOGRAPHY 色谱 丙烯 微量 硫化

链接地址:http://www.mydoc123.com/p-519423.html