ASTM D4864-1990(2013) Standard Test Method for Determination of Traces of Methanol in Propylene Concentrates by Gas Chromatography《用气相色谱法测定丙烯浓缩物中痕量甲醇的标准试验方法》.pdf
《ASTM D4864-1990(2013) Standard Test Method for Determination of Traces of Methanol in Propylene Concentrates by Gas Chromatography《用气相色谱法测定丙烯浓缩物中痕量甲醇的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4864-1990(2013) Standard Test Method for Determination of Traces of Methanol in Propylene Concentrates by Gas Chromatography《用气相色谱法测定丙烯浓缩物中痕量甲醇的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4864 90 (Reapproved 2013)Standard Test Method forDetermination of Traces of Methanol in PropyleneConcentrates by Gas Chromatography1This standard is issued under the fixed designation D4864; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of methanolin propylene concentrates in th
3、e range of approximately 4 to 40mg/kg (parts-per-million by weight).1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.NOTE 1There is no direct acceptable SI equivalent for screw threads.1.3 This standard does not purport to addre
4、ss all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific warningstatements are given in 11.1.1, 11.2.1, a
5、nd 12.11.2. Referenced Documents2.1 ASTM Standards:2D4307 Practice for Preparation of Liquid Blends for Use asAnalytical StandardsE260 Practice for Packed Column Gas Chromatography3. Terminology3.1 Definitions:3.1.1 propylene concentrateconcentrate containing morethan 90 % propylene.3.2 Definitions
6、of Terms Specific to This Standard:3.2.1 outage tubea length of 6.35-mm (14 in.) outsidediameter SS tubing normally attached to the inside end of avalve used on a pressure sampling cylinder. It is used tofacilitate removal of a set quantity of liquified sample toprevent overpressuring the cylinder.4
7、. Summary of Test Method4.1 A known weight of water is pressured into a samplecylinder containing a known amount of liquified propylene.The contents in the cylinder are shaken and the water/methanolphase is withdrawn. A reproducible volume of the extract isthen injected into a gas chromatograph (GC)
8、 equipped witheither a thermal conductivity or a flame ionization detector.The methanol concentration is calculated from the area of themethanol peak using calibration and extraction factors obtainedfrom synthetic blends of known methanol content.5. Significance and Use5.1 Methanol is a common impur
9、ity in propylene. It canhave a deleterious effect on various processes that use propyl-ene as a feedstock.6. Interferences6.1 There are no known interferences using the GC columnsreferenced in this test method. However, any water-solublecomponent that co-elutes with methanol on any other GCcolumn us
10、ed would interfere.7. Apparatus7.1 Gas ChromatographAny GC equipped with eitherflame ionization or thermal conductivity detectors with anoverall sensitivity sufficient to detect at least 4 mg/kg ofmethanol.7.2 ColumnAny GC column that separates methanol fromwater, other alcohols, and any co-extracte
11、d hydrocarbons.NOTE 2See Table 1 for a suitable list of columns and Fig. 1 and Fig.2 for examples of chromatograms. Also, refer to Practice E260 for typicalinstructions in preparing such columns. Alternatively, columns can bepurchased from commercial sources.7.3 Data Handling SystemAny commercially
12、availableGC integrator or GC computer system capable of accuratelyintegrating the area of the methanol peak is satisfactory.7.4 RecorderA strip-chart recorder with a full scale re-sponse of2sorless and a maximum noise rate of 60.3 % fullscale.7.5 Sample Cylinders, 300-mL capacity, stainless steel,Ty
13、pe DOT 3E (12409 kPa (1800 psig) working pressure).1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricantsand is the direct responsibility ofSubcommittee D02.D0.03 on Propylene.Current edition approved Nov. 15, 2013. Published November 201
14、3. Originallyapproved in 1988. Last previous edition approved in 2005 as D4864 90 (2005).DOI: 10.1520/D4864-90R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to th
15、e standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.6 BalancesAny types capable of weighing a 300-mLsample cylinder and contents accurately to 0.1 g and a 25-mLvolumetric flask and co
16、ntents accurately to 0.0001 g.7.7 Plug Valve,14-in. male NPT or optionally,14-in. maleNPT to 6.35 mm outside diameter (14 in.) tubing. (See Note 3.)7.8 Shut-off Valves,14-in. male NPT to 6.35 mm outsidediameter (14 in.) tubing.7.9 Regulating Valves,14-in. male NPT and14-in. male NPTto14-in. female N
17、PT.7.10 Hex Nipple, SS,14-in. male NPT by 102 mm (4 in.)long.7.11 Hex Coupling, SS,14-in. female NPT by 30 mm (1.2in.) long.7.12 Brass Cap,14-in. NPT or optionally, a tube fitting nut,6.35 mm outside diameter (14 in.). (See Note 3.)7.13 Septum, TFE-fluorocarbon lined, 11-mm diameter.7.14 Syringes, 1
18、0 and 25 L.8. Reagents and Materials8.1 Methanol, reagent grade or better.8.2 Propylene, 92+ % purity containing 0.2 mg/kg (ppmw)methanol.9. Sampling9.1 The propylene sample shall be in the liquified state andbe representative of the material in the storage tank or processline. Also, for purposes of
19、 this method as well as for safetyconsiderations, there must be a vapor space of about 15 % inthe sampling container. It is recommended that samplingcylinders of the type listed in Section 7 be used. They can beequipped with an outage tube to effect the 15 % vapor spacerequirement.TABLE 1 Suitable G
20、as Chromatographic Columns and TemperaturesAColumnNumberColumn Size, m mm Tubing Type Packing Coating, m ThicknessOven Temperature,C1 1.22 6.35 OD SS 15 % Carowax 1540 on 60/80Chromosorb W AW. 902 3.05 4.76 OD SS 80/100 mesh Porapak QS . 1003 3.05 6.35 OD Cu 10 % Carbowax 1540 on30/60 mesh Chromosor
21、b T. 1204 6.10 6.35 OD Cu 10 % Carbowax 1540 on30/60 mesh Chromosorb T. 1205 1.83 2 ID glass 10 % Carbowax 20 M on 80/100 Chromosorb W AW. 706 15 0.53 ID fused silica . J detector: flame ionization.FIG. 1 Chromatograms of Water/Methanol Standard and Water/Methanol/Propylene ExtractANOTE 1Column used
22、: No. 4 of Table 1; detector: thermal conductiv-ity.FIG. 2 Chromatogram of Water/Methanol/Propylene ExtractD4864 90 (2013)210. Preparation of Apparatus10.1 Prepare a water injection device. A suitable device isshown in Fig. 3. However, any other device that will deliverfrom 8 to 15 g of water can be
23、 used.10.2 Prepare a 300-mL sample cylinder for use as a metha-nol cylinder, as shown in Fig. 4. (This cylinder must notcontain an outage tube.) Drilla3to4mm(approximately18in.) hole in a14-in. NPT brass cap, insert an 11-mm septum intoit, and screw it onto the plug valve.NOTE 3As an alternative, th
24、e cylinder can be equipped with14-in.male NPT to a 6.35-mm (14-in.) outside diameter tubing plug valve. Thena 6.35-mm tube fitting nut can be used with the septum, thus avoiding thenecessity of drilling a brass cap.10.3 Set up the chromatograph in accordance with themanufacturers recommendations. In
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD486419902013STANDARDTESTMETHODFORDETERMINATIONOFTRACESOFMETHANOLINPROPYLENECONCENTRATESBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-518249.html