1、Designation: D 4266 96 (Reapproved 2009)1Standard Test Methods forPrecoat Capacity of Powdered Ion-Exchange Resins1This standard is issued under the fixed designation D 4266; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUpdated 5.2 editorially in June 2009.1. Scope1.1 These test methods cover the determination of theoperating ion-exchange
3、capacity of both powdered cation-exchange resins (hydrogen form) and powdered anion-exchange resins (hydroxide form). These test methods areintended for use in testing new powdered ion-exchange resinswhen used for the treatment of water. The following two testmethods are included:SectionsTest Method
4、 AOperating Capacity, Anion-ExchangeResin, Hydroxide Form7 to 15Test Method BOperating Capacity, Cation-ExchangeResin, Hydrogen Form16 to 241.2 The values stated in SI units are to be regarded as thestandard. The inch-pound units given in parentheses are forinformation only.1.3 This standard does no
5、t purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standard
6、s:2D 1125 Test Methods for Electrical Conductivity and Re-sistivity of WaterD 1129 Terminology Relating to WaterD 1193 Specification for Reagent WaterD 2687 Practices for Sampling Particulate Ion-ExchangeMaterialsD 4456 Test Methods for Physical and Chemical Propertiesof Powdered Ion Exchange Resins
7、E 200 Practice for Preparation, Standardization, and Stor-age of Standard and Reagent Solutions for ChemicalAnalysis3. Terminology3.1 Definitions of Terms Specific to This Standard:DefinitionsFor definitions of other terms used in these testmethods, refer to Terminology D 1129.3.1.1 powdered ion-exc
8、hange material, nan ion-exchangeresin that has undergone post-manufacturing size reduction toless than 300 m.3.1.2 resin dosage, nthe weight of mixed resin applied perunit area of precoatable filter surface. This is expressed as drypounds per square foot.3.1.3 resin floc, nthat voluminous aggregate
9、formed whenpowdered anion-exchange resin and powdered cation-exchange resin are slurried together in an aqueous suspension.3.1.4 resin ratio, nthe ratio of the weights of powderedcation-exchange resin to powdered anion-exchange resin usedto prepare a resin slurry. If not otherwise indicated, it isun
10、derstood to be the ratio of the dry resin weights.4. Significance and Use4.1 The salt removal capacity of a powdered resin precoat islimited by the capacity of either the anion-exchange resin orthe cation-exchange resin contained in it. Applications includecondensate polishing in fossil-fueled elect
11、ric generating plants,as well as condensate polishing, spent fuel pool water treat-ment, reactor water treatment, and low-level radioactive liquidwaste treatment in nuclear-powered electric generating plants.4.2 By determining the ion-exchange capacity profile ofeither a cation exchange resin or an
12、anion-exchange resin(capacity expended per unit of time under specific conditions),it is possible to estimate runlength and remaining capacitywhen treating a liquid of the same makeup. Although theycannot accurately predict performance during condenser leaks,these test methods are useful for determi
13、ning operating capaci-ties as measured under the test conditions used.4.3 These test methods may be used to monitor the perfor-mance of either powdered anion-exchange resin or powderedcation-exchange resin. The total capacity of either resin de-pends primarily upon the number density of ion-exchange
14、 siteswithin the resin. The operating capacity is a function of the1These test methods are under the jurisdiction of ASTM Committee D19 onWater and are the direct responsibility of Subcommittee D19.08 on Membranes andIon Exchange Materials.Current edition approved May 1, 2009. Published June 2009. O
15、riginallyapproved in 1983. Last previous edition approved in 2007 as D 4266 96 (2007).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary
16、 page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.total capacity, degree of conversion to the desired ionic formwhen received, and properties of the resin and the system thataffect ion exchange kinetics.5. Puri
17、ty of Reagents5.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shallconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society, where suchspecifications are available.35.2 Purity of WaterUnl
18、ess otherwise indicated, referencesto water shall be understood to mean Type II reagent water,Specification D 1193.6. Sampling6.1 Obtain a representative sample of the powdered ion-exchange resin in accordance with Practices D 2687 butsubstituting a 12.5-mm (12-in.) inside diameter tube.TEST METHOD
19、AOPERATING CAPACITY,ANION-EXCHANGE RESIN, HYDROXIDE FORM7. Scope7.1 This test method covers the determination of ion-exchange capacity, on a dry weight basis, of new powderedanion-exchange resins in the hydroxide form.7.2 The ion-exchange capacity obtainable in commercialinstallations depends not on
20、ly upon the initial state of thepowdered resin, but also on how the resin floc is prepared andapplied, on the condition of the equipment on which it is to beused, and the pH and general chemistry of the water systembeing treated. Thus, this test method has comparative ratherthan predictive value and
21、 provides an upper limit on exchangecapacity that may be expected.8. Summary of Test Method8.1 The powdered anion-exchange resin to be tested isslurried with an appropriate amount of powdered cation-exchange resin in the hydrogen form, and the resulting floc isprecoated onto a filter disk. Then a di
22、lute standardized solutionof a strong acid is fed to the precoat while monitoring theeffluent stream conductometrically.9. Apparatus9.1 Test apparatus, as shown in Fig. 1, with the followingcomponents:9.1.1 Water Pumpadjustable between 0 to 7.57 L/min (0to 2 gal/min) at 2.76 3 105Pa (40 psig) pressu
23、re.49.1.2 Pressure Gauges (two), 0 to 4.137 3 105Pa (0 to 60psig) with appropriate snubbers.9.1.3 Disk Filter Holder, 142-mm diameter with sufficientclearance above the filter disk to allow for uniform applicationof resin precoat.59.1.4 Filter-Disk, 142-mm diameter, with nominal retentionrating of 2
24、5 to 30 m and absolute retention rating of 40 to60m.69.1.5 Flow Meter, 0 to 1.89 L/min (0 to 30 gal/h) withregulating valve.9.1.6 Beaker, stainless steel, 4 L to volume with bulkheadfittings installed at tubing penetrations.9.1.7 Chemical Pump, with pumping rate between8.33 3 106and 8.33 3 105L/s (3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD426619962009E1STANDARDTESTMETHODSFORPRECOATCAPACITYOFPOWDEREDIONEXCHANGERESINS 粉状 离子交换 树脂 预涂覆 能力

链接地址:http://www.mydoc123.com/p-516669.html