ASTM D4239-2013 Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion《高温管式炉燃烧法测定煤和焦炭分析样品中硫含量的标准试验方法》.pdf
《ASTM D4239-2013 Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion《高温管式炉燃烧法测定煤和焦炭分析样品中硫含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4239-2013 Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion《高温管式炉燃烧法测定煤和焦炭分析样品中硫含量的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4239 12D4239 13Standard Test Method forSulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion1This standard is issued under the fixed designation D4239; the number immediately following the designation indicates the year oforiginal adoption or, in
2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 Th
3、is test method covers the determination of sulfur in samples of coal or coke by high-temperature tube furnace combustion.1.1.1 Two analysis methods are described.1.2 When automated equipment is used, either method can be classified as an instrumental method.1.3 The values stated in SI units are to b
4、e regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and
5、 determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D346 Practice for Collection and Preparation of Coke Samples for Laboratory AnalysisD2013 Practice for Preparing Coal Samples for AnalysisD3173 Test Method for Moisture in the Analysis Sampl
6、e of Coal and CokeD3176 Practice for Ultimate Analysis of Coal and CokeD3180 Practice for Calculating Coal and Coke Analyses from As-Determined to Different BasesD7448 Practice for Establishing the Competence of Laboratories UsingASTM Procedures in the Sampling andAnalysis of Coaland CokeD7582 Test
7、Methods for Proximate Analysis of Coal and Coke by Macro Thermogravimetric AnalysisE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method2.2 ISO Standard:3ISO 11722 Solid Mineral Fuels-Hard Coal Determination of Moisture in the general analysis test sample
8、by drying in nitrogen3. Summary of Test Method3.1 Combustion Method A (1350C)A weighed test portion of sample is burned in a tube furnace at a minimum combustiontube operating temperature of 1350C in a stream of oxygen. During combustion at temperatures above 1350 C, the sulfur andsulfur compounds c
9、ontained in the sample are decomposed and oxidized almost exclusively to gaseous sulfur dioxide, SO2.Moisture and particulates are removed from the gas by filters. The gas stream is passed through a cell in which sulfur dioxide ismeasured by an infrared (IR) absorption detector. Sulfur dioxide absor
10、bs IR energy at a precise wavelength within the IR spectrum.Energy is absorbed as the gas passes through the cell body in which the IR energy is being transmitted: thus, at the detector, lessenergy is received.All other IR energy is eliminated from reaching the detector by a precise wavelength filte
11、r. Thus, the absorptionof IR energy can be attributed only to sulfur dioxide whose concentration is proportional to the change in energy at the detector.One cell is used as both a reference and a measurement chamber. Total sulfur as sulfur dioxide is detected on a continuous basis.3.1.1 One procedur
12、e for Method A uses coal or coke reference materials to calibrate the sulfur analyzer. A second procedurefor Method A uses a pure substance, BBOT, to calibrate the sulfur analyzer.1 This test method is under the jurisdiction of ASTM Committee D05 on Coal and Coke and is the direct responsibility of
13、Subcommittee D05.21 on Methods of Analysis.Current edition approved Feb. 1, 2012Oct. 1, 2013. Published February 2012October 2013. Originally approved in 1983. Last previous edition approved in 20112012 asD4239 11.D4239 12. DOI: 10.1520/D4239-12.10.1520/D4239-13.2 For referencedASTM standards, visit
14、 theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from International Organization for Standardization (ISO), 1, ch. de la Voie-Creuse, C
15、ase postale 56, CH-1211, Geneva 20, Switzerland, http:/www.iso.ch.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict al
16、l changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-29
17、59. United States13.2 Combustion Method B (1150C)A weighed test portion of sample is burned in a quartz combustion tube in a stream ofoxygen with an equal or excess weight of tungsten trioxide (WO3). Sulfur is oxidized during the reaction of the sample and WO3.The tube furnace is operated at a minim
18、um combustion tube operating temperature of 1150C and tin (Sn) sample boats areutilized. Moisture and particulates are removed from the combustion gas by filters. The gas stream is then passed through a cellin which sulfur dioxide is measured by an infrared (IR) absorption detector. Sulfur dioxide a
19、bsorbs IR energy at a precisewavelength within the IR spectrum. Energy is absorbed as the gas passes through the cell body in which the IR energy is beingtransmitted: thus, at the detector, less energy is received. All other IR energy is eliminated from reaching the detector by a precisewavelength f
20、ilter. Thus, the absorption of IR energy can be attributed only to sulfur dioxide whose concentration is proportionalto the change in energy at the detector. One cell is used as both a reference and a measurement chamber. Total sulfur as sulfurdioxide is detected on a continuous basis.4. Significanc
21、e and Use4.1 Sulfur is part of the ultimate analysis of coal and coke.4.2 Results of the sulfur analysis are used for evaluation of coal preparation and cleaning, evaluation of potential sulfuremissions from coal and coke combustion or conversion processes, and evaluation of coal and coke quality in
22、 relation to contractspecifications, as well as for scientific purposes.4.3 The competency of laboratories with respect to use of this standard can be established through reference to Practice D7448.5. Sample5.1 Pulverize the sample to pass No. 60 (250-m) sieve and mix thoroughly in accordance with
23、Practice D2013 or PracticeD346.5.2 Analyze a separate portion of the analysis sample for moisture content in accordance with Test Method D3173, or D7582or ISO 11722 for calculations to other than the as-determined basis.5.3 Procedures for calculating as-determined sulfur values obtained from the ana
24、lysis sample to other bases are described inPractices D3176 and D3180.6. ApparatusCombustion Method A (1350C)6.1 Measurement ApparatusEquipped to combust the sample as described in 3.1 (See Fig. 1).6.2 Tube FurnaceCapable of heating the hot zone or outer surface of the combustion tube, or both (6.3)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD42392013STANDARDTESTMETHODFORSULFURINTHEANALYSISSAMPLEOFCOALANDCOKEUSINGHIGHTEMPERATURETUBEFURNACECOMBUSTION

链接地址:http://www.mydoc123.com/p-516614.html