ASTM D4032-2008 Standard Test Method for Stiffness of Fabric by the Circular Bend Procedure《用圆形弯曲法测定织物挺度的标准试验方法》.pdf
《ASTM D4032-2008 Standard Test Method for Stiffness of Fabric by the Circular Bend Procedure《用圆形弯曲法测定织物挺度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4032-2008 Standard Test Method for Stiffness of Fabric by the Circular Bend Procedure《用圆形弯曲法测定织物挺度的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4032 08Standard Test Method forStiffness of Fabric by the Circular Bend Procedure1This standard is issued under the fixed designation D 4032; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the stiff-ness of fabrics by the circular bend procedure.1.2 This test method is genera
3、lly applicable to all types offabrics, including woven, knitted and nonwovens, of any fibercontent.NOTE 1For other methods of testing for stiffness, refer to TestMethods D 1388.1.3 The values stated in SI units are to be considered asstandard; the values in inch-pound units are included forinformati
4、on only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Refe
5、renced Documents2.1 ASTM Standards:2D 123 Terminology Relating to TextilesD 1388 Test Method for Stiffness of FabricsD 1776 Practice for Conditioning and Testing TextilesD 4850 Terminology Relating to Fabric3. Terminology3.1 For all terminology relating to D13.60, Fabric TestMethods, Specific, refer
6、 to Terminology D 4850.3.1.1 The following terms are relevant to this standard:circular bend, stiffness.3.2 For all other terminology related to textiles, see Termi-nology D 123.4. Summary of Test Method4.1 A plunger forces a flat, folded swatch of fabric throughan orifice in a platform. The maximum
7、 force required to pushthe fabric through the orifice is an indication of the fabricstiffness (resistance to bending).5. Significance and Use5.1 Test Method D 4032 for testing stiffness of fabrics isconsidered satisfactory for quality control testing. It may alsobe used for acceptance testing of com
8、mercial shipments sincethe test method has been used extensively in the trade field. Incases of differences in values reported by purchaser and sellerusing Test Method D 4032 for acceptance testing, the statisticalbias, if any, between the laboratories of the purchaser and theseller should be determ
9、ined with each comparison being basedon the testing of specimens taken homogeneously from a lot ofmaterial of the type being evaluated. Specimens should berandomly assigned in equal numbers to each of the laborato-ries.5.2 The circular bend procedure gives a force value relatedto fabric stiffness, s
10、imultaneously averaging stiffness in alldirections. The stiffness tests in Test Methods D 1388 are of thesingle directional type.5.3 The circular bend procedure is simple to perform andmay be used for knitted, woven, or nonwoven fabrics, providedgage capacity is in keeping with fabric range tested.6
11、. Apparatus6.1 Circular Bend Stiffness Tester,3(Figs. 1 and 2), havingthe following parts:6.1.1 Platform,102by102by6mm(4by4by14 in.)smooth-polished chrome-plated steel plate with a 38.1-mm(1.50-in.) diameter orifice. The lap edge of the orifice should beat a 45 angle to a depth of 4.8 mm (316 in.) (
12、see Fig. 3).6.1.2 Plunger, 25.4-mm (1.00-in.) diameter, mounted con-centric with orifice, 6.4 mm (0.25 in.) clearance on all sides.The bottom of the plunger should be set at 3 mm (18 in.) abovethe top of the orifice plate. From this position, the downwardstroke length is 57 mm (214 in.).6.1.3 Force-
13、Measurement Gage, dial or digital type (see9.3).6.1.3.1 Dial gages with maximum reading pointer in differ-ent capacities ranging from 1 to 50 lbf, 0.5 to 25 kgf, or 5 to200 N with 100 graduations minimum; or1This test method is under the jurisdiction of ASTM Committee D13 on Textilesand is the direc
14、t responsibility of Subcommittee D13.60 on Fabric Test Methods,Specific.Current edition approved June 1, 2008. Published July 2008. Originally approvedin 1981. Last previous edition approved in 2001 as D 4032 94(2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AS
15、TM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Apparatus is commercially available.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Unite
16、d States.6.1.3.2 Digital gage with maximum reading “hold” featureand capacity of 100 lbf, 50 kgf, or 500 N, with 1000graduations minimum.6.1.4 Actuator, manual or pneumatic.6.2 Specimen Marking Template, (102 by 204 mm) 4.0 by8.0 in.6.3 Stop Watch, for checking stroke speed.7. Sampling7.1 Lot SizeFo
17、r sampling purposes, a lot is defined as asingle shipment of a single style of fabric. A lot may constituteall or part of a single customer order.7.2 Lot SampleAs a lot sample for acceptance testing;take at random the number of rolls of fabric directed in anapplicable material specification or other
18、 agreement betweenthe purchaser and the supplier. Consider rolls of fabric to be theprimary sampling units.NOTE 2An adequate specification or other agreement between thepurchaser and the supplier requires taking into account the variabilitybetween rolls of fabric and between specimens from a swatch
19、from a rollof fabric to provide a sampling plan with a meaningful producers risk,consumers risk, acceptable quality level, and limiting quality level.7.3 Laboratory SampleAs a laboratory sample for accep-tance testing, take a full swatch 1 m (1 yd) long from the endof each roll of fabric in the lot
20、sample, after first discarding aminimum of1m(1yd)offabric from the very outside of therolls.8. Number and Preparation of Test Specimens8.1 Using the specimen marking template specified in 6.2,mark and cut five test specimens from staggered areas of eachswatch in the laboratory sample. The short side
21、 of the specimenmust be parallel to the machine (length) direction of the fabric.Cut no specimens closer to the selvage than one tenth of thefabric width. Lay each specimen face down and fold thespecimen once to form a square 4 by 4 in. (102 by 102 mm).After folding, use the template and hand pressu
22、re to flatten thecrease. Handling of specimens must be kept to a minimum andto the edges to avoid affecting stiffness properties.NOTE 3When otherwise agreed upon, as when specified in anapplicable material specification, the purchaser and the seller may changethe number of test specimens per swatch
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD40322008STANDARDTESTMETHODFORSTIFFNESSOFFABRICBYTHECIRCULARBENDPROCEDURE 圆形 弯曲 测定 织物 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-516106.html