《ASTM D3907-2003 Standard Test Method for Testing Fluid Catalytic Cracking (FCC) Catalysts by Microactivity Test《微活性试验法测试流化床催化裂化(FCC)催化剂的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3907-2003 Standard Test Method for Testing Fluid Catalytic Cracking (FCC) Catalysts by Microactivity Test《微活性试验法测试流化床催化裂化(FCC)催化剂的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3907 03Standard Test Method forTesting Fluid Catalytic Cracking (FCC) Catalysts byMicroactivity Test1This standard is issued under the fixed designation D 3907; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers determining the activity ofequilibrium or laboratory-deactivated fluid catalytic crackin
3、g(FCC) catalysts, or both. This is evaluated on the basis ofweight percent conversion of gas oil in a microactivity unit.The selectivity of FCC catalysts can be determined using TestMethod D 5154.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are pro
4、vided forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations pr
5、ior to use.2. Referenced Documents2.1 ASTM Standards:2D 2887 Test Method for Boiling Range Distribution ofPetroleum Fractions by Gas ChromatographyD 5154 Test Method for Determining the Activity andSelectivity of Fluid Catalytic Cracking (FCC) Catalysts byMicroactivity Test3E 105 Practice for Probab
6、ility Sampling of MaterialsE 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 456 Terminology Relating to Quality and StatisticsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions of Terms Specific to
7、 This Standard:3.1.1 ASTM consensus mean conversioneach referencecatalyst has a consensus mean conversion value assigned to itby Committee D32 (see 11.2).3.1.2 ASTM reference catalystsa set of equilibrium fluidcracking catalysts with conversions within the useful range ofthis test method is used to
8、improve the reproducibility of testresults between different laboratories. Samples of the ASTMreference catalysts can be obtained from NIST.3.1.3 ASTM standard feeda specific batch of gas oil that isused as feedstock in the described test method. This standardfeed can be obtained from the National I
9、nstitute of Standardsand Technology (NIST).43.1.4 conversion calibration curvea calibration curve canbe obtained by plotting the consensus mean conversion valuesfor the ASTM reference catalysts (see 11.2) versus the indi-vidual laboratory-measured conversion for the same catalysts.3.1.5 measured con
10、versionis calculated as the differencebetween the weight of feed used and the weight of unconvertedmaterial, divided by the weight of feed used, times 100 %. Theunconverted material is defined as all liquid product with aboiling point above 216C (421F).4. Summary of Test Method4.1 A sample of cracki
11、ng catalyst in a fixed-bed reactor iscontacted with gas oil (ASTM standard feed). Cracked liquidproducts are analyzed for unconverted material and the con-version is calculated.4.2 A corrected conversion value can be obtained from themeasured conversion and the conversion calibration curve.5. Signif
12、icance and Use5.1 The microactivity test provides data to assess the rela-tive performance of FCC catalyst. Because results are affectedby catalyst pretreatment, feedstock characteristics, test equip-ment, and operating parameters, adherence to this test methodis a prerequisite for correct interpret
13、ation of results. Apparatus,test conditions, and analytical procedures actually used shouldclosely resemble those described in this test method.5.2 Caution should be used in interpreting results above 80weight % conversion due to the significance of overcracking.1This test method is under the jurisd
14、iction of ASTM Committee D32 onCatalysis and is the direct responsibility of Subcommittee D32.04 on CatalyticProperties.Current edition approved Oct. 1, 2003. Published October 2003. Originallyapproved in 1992. Discontinued in 2001 and reinstated as D 390703. Last previousedition approved in 2000 as
15、 D 390700.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4Available from National Institute of St
16、andards and Technology (NIST), 100Bureau Dr., Stop 3460, Gaithersburg, MD 20899-3460.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. Apparatus6.1 Flow ChartThe flow chart is given in Fig. 1. During75 s, gas oil from a syringe is f
17、orced over4gofcatalyst in afixed-bed reactor. Liquid products are collected in a receiverand kept at a wet ice temperature.6.2 SyringeA syringe with 2.5 mL capacity is used for oiladdition. It should be equipped with a multiport, high-pressurevalve to allow nitrogen and oil entry to the reactor thro
18、ugh acommon feed line.6.3 Syringe HeaterHeat syringe to 40 6 5C (104 6 9F)using a heat lamp or resistance heater or any other suitablemeans.6.4 Syringe PumpA syringe pump that can deliver uni-form flow of 1.33 6 0.03 g of gas oil in 75 6 1s.6.5 FurnaceA three-zone furnace is used: middle zone,150-mm
19、 (6-in.) length, and top and bottom zones, 75-mm(3-in.) length. The catalyst bed is positioned in the middlezone. The temperature controllers of the three zones arecalibrated to achieve a constant temperature 482 6 1C (900 62F) over the whole length of the catalyst bed (actual bedtemperature).6.6 Re
20、actor and InsertA glass or stainless steel reactor of15.6 mm internal diameter is used. Dimensions are shown inFig. 2. Details of the reactor insert are shown in Figs. 2 and 3.NOTE 1General dimensions are given in SI units. Dimensions givenin SAE, U.S. Standard gage sizes for sheet, tubing, and wire
21、 areconsidered standard. In general, the closest metric equivalent should beadequate for proper functioning.6.7 Liquid Product Collection SystemLiquid product iscollected in the receiver shown in Fig. 4.6.8 Analytical Balance and WeightsThe balance used toweigh the sample, the receiver, and the syri
22、nge shall have aprecision of 1 mg. Analytical weights shall be precision gradeor calibrated against a set of certified standard weights.6.9 Chromatographic EquipmentThe gas chromato-graphic equipment specified in Test Method D 2887 is sug-gested for the analysis of liquid product. A flame ionization
23、detector is recommended.7. Sampling7.1 If a sampling procedure is desired, Practice E 105 isrecommended.8. Sample Preparation8.1 Dry samples or decoke, or both, by heating a shallow(less than 10 mm thick) bed of catalyst in a porcelain crucibleas follows:120 6 20C (248 6 36F) for 1 h120C (248F) to 5
24、90C (1094F) for approximately 1 h590 6 20C (1094 6 36F) for 3 h8.2 Sufficient air should be available in the furnace to burnthe sample free of coke. Insufficient decoking is indicated by adifference in color of the top and bottom layers. The hotcrucible is cooled in a desiccator to prevent moisture
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD39072003STANDARDTESTMETHODFORTESTINGFLUIDCATALYTICCRACKINGFCCCATALYSTSBYMICROACTIVITYTEST 活性 试验

链接地址:http://www.mydoc123.com/p-515772.html