1、Designation: D 3902 90 (Reapproved 2004)e1Standard Test Method forRubber Hose for Gas Diffusion of Liquefied Petroleum Gas1This standard is issued under the fixed designation D 3902; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEWarning notes were editorially moved into the standard text in July 2004.1. Scope1.1 This test method covers th
3、e determination of the volumeof liquefied petroleum gas diffusing through the wall of a hoseduring a specified period of time.1.2 The values stated in SI units are to be regarded asstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It i
4、s theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.A specific precau-tionary statement is given in the note in Section 5.2. Significance and Use2.1 Rubber hose has an inherent
5、characteristic of permittingdiffusion of a gas through the hose structure. This test methodquantitatively measures the loss of liquefied petroleum gas.3. Apparatus3.1 Water Bath, long enough to accommodate the gas-collecting apparatus and hose.3.2 Gas Supply, provided with a suitable pressure gage a
6、ndemergency excess flow shutoff valve in case of hose failure.3.3 Set of Gas-Collecting Apparatus, consisting of a glasstube at least 10 % longer than the hose being tested and with aninside diameter at least 10 % larger than the outside diameter ofthe hose being tested, a conical funnel 25 mm in di
7、ameter, anda 500-cm3measuring cylinder graduated at 5.0-cm3intervals.3.4 Barometer, to record the barometric pressure during thetest.3.5 Thermometers, two, to record water and air temperatureat the gas-collection point. (For a schematic diagram of the testarrangement, see Fig. 1.)3.6 LP-Gas,2having
8、a minimum purity of 99 mol % pro-pane, and a sulfur content less than 0.005 mass %.4. Test Hose4.1 The test hose shall have a 0.50-m (19.7-in.) free lengthbetween couplings and shall be coupled with suitable cou-plings, that is, band-it-type couplings. If the test hose is rubbercovered, then the cov
9、er should be thoroughly perforated with apricker roll.5. Test Pressure5.1 Unless otherwise specified, conduct the test with theLP-gas in the liquid phase at a pressure of 1000 6 20 kPa (1456 3 psi). Regulate this pressure by keeping the LP-gas tank inthe water bath and adjusting the temperature of t
10、he water toobtain the desired pressure, approximately 28C. (WarningTake special precautions to ensure that the water bath tempera-ture cannot rise accidently, as this will increase the gas pressuresignificantly, creating a danger of explosion. Do the testing ina well-ventilated area. The system shal
11、l be equipped with asafety relief valve set at a gage pressure of 1200 6 35 kPa (1756 5 psi).)6. Procedure6.1 Cap or plug the hose coupling on one end of the testhose and connect the hose coupling on the other end to theLP-gas supply. (Invert the tank when testing in the liquid phaseor use a tank eq
12、uipped with full-length dip tube.)6.2 Flush the inside surface of the test hose with LP-gas toremove air and seal the end.6.3 Locate the test hose in the center of the glass tube andmount in the water bath at an incline angle of approximately20.6.4 Adjust the water bath to the specified temperature.
13、Apply the specified gas pressure to the test hose and maintainthis pressure and the water bath temperature for 14 days. At theend of the 14-day conditioning period, inspect the test appara-tus for leaks and, in particular, the area around the hosecouplings. Leaks will be evident by the formation of
14、gasbubbles in the water bath. If none are found, insert the funnelinto the measuring cylinder, fill the cylinder with water, andmount the funnel over the end of the glass tube.6.5 Collect the gas for a 6-h period or collect 450 to 500 cm3of gas, whichever occurs first, and record the time and thevol
15、ume of gas collected. Repeat this procedure every 24 h until1This test method is under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.31 on Rubber Hose andBelting.Current edition approved July 1, 2004. Published July 2004. Originally approvedin 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD390219902004E1STANDARDTESTMETHODFORRUBBERHOSEFORGASDIFFUSIONOFLIQUEFIEDPETROLEUMGAS 液化 石油气 气体 扩散

链接地址:http://www.mydoc123.com/p-515763.html