《ASTM D3900-2005a(2010) Standard Test Methods for Rubber-Determination of Ethylene Units in Ethylene-Propylene Copolymers (EPM) and in Ethylene-Propylene-Diene Terpolymers (EPDM) by.pdf》由会员分享,可在线阅读,更多相关《ASTM D3900-2005a(2010) Standard Test Methods for Rubber-Determination of Ethylene Units in Ethylene-Propylene Copolymers (EPM) and in Ethylene-Propylene-Diene Terpolymers (EPDM) by.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3900 05a (Reapproved 2010)Standard Test Methods forRubberDetermination of Ethylene Units in Ethylene-Propylene Copolymers (EPM) and in Ethylene-Propylene-Diene Terpolymers (EPDM) by Infrared Spectrometry1This standard is issued under the fixed designation D3900; the number immediately
2、following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test m
3、ethods cover the determination of theproportion of ethylene and propylene units in ethylene-propylene copolymers (EPM) and ethylene-propylenedieneterpolymers (EPDM) over the range from 35 to 85 mass %ethylene. Four test methods are needed to encompass thevariety of commercial polymers that contain a
4、dditives orpolymerized diene units that interfere with the various infraredpeaks. Except when interferences are present, all four testmethods should give similar results.The test methods appear inthe following order:1.1.1 Pressed Film Test Methods:SectionsTest Method AFor EPM and EPDM between 35 and
5、 70mass % ethylene9-14Test Method BFor EPM and EPDM between 60 and 85mass % ethylene, except for ethylene/propylene/1,4-hexadiene terpolymers15-19Test Method CFor all EPM and EPDM polymers between 35and 85 mass % ethylene, using near infrared20-241.1.2 Cast Film Test Methods:Test Method DFor all EPM
6、 and EPDM polymers between 35and 85 mass % ethylene, except for ethylene/propylene/1,4-hexadiene terpolymers25-321.2 These test methods are not applicable to oil-extendedEPDM unless the oil is first removed in accordance with TestMethod D.1.3 The values stated in SI units are to be regarded asstanda
7、rd. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applic
8、a-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D297 Test Methods for Rubber ProductsChemicalAnaly-sisD3568 Test Methods for RubberEvaluation of EPDM(Ethylene Propylene Diene Terpolymers) Including Mix-tures With OilD4483 Practice for Evaluating Precision f
9、or Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustriesE168 Practices for General Techniques of Infrared Quanti-tative Analysis3. Summary of Test Methods3.1 Test Method APressed films are measured for theirinfrared absorbance ratios at 8.65/13.85 m (1156/722 cm1),and mass perc
10、ent ethylene is read from a calibration obtainedfrom standard polymers.3.2 Test Method BThin pressed films are measured fortheir infrared absorbance ratios at 7.25/13.85 m (1379/722cm1), and mass percent ethylene is read from a calibrationobtained from standard polymers.3.3 Test Method CPressed film
11、s are measured for theirinfrared absorbance ratios at 8.65/2.35 m (1156/4255 cm1)using near infrared, and mass percent ethylene is read from acalibration obtained from standard polymers.3.4 Test Method DUltra-thin cast films on a salt plate aremeasured for their infrared absorbance ratios at 7.25/6.
12、85 m(1379/1460 cm1), and mass percent ethylene is read from acalibration obtained from standard polymers.4. Significance and Use4.1 These test methods can be used for determining whichEPDM polymers are evaluated in the different compounds inTest Methods D3568.1These test methods are under the jurisd
13、iction of ASTM Committee D11 onRubber and are the direct responsibility of Subcommittee D11.11 on ChemicalAnalysis.Current edition approved June 1, 2010. Published December 2010. Originallyapproved in 1980. Last previous edition approved in 2005 as D3900 05a. DOI:10.1520/D3900-05AR10.2For referenced
14、 ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Cons
15、hohocken, PA 19428-2959, United States.4.2 Differences in ethylene sequence distribution causedifferences in crystallinity and green strength at the sameethylene content. Since these are important variables in EPMand EPDM processability and end-use properties, the ethylenecontent of the rubber shoul
16、d not be used as the sole measure-ment to determine the suitability of a particular rubber for anintended purpose.5. Interferences5.1 Ethylene/propylene/1,4-hexadiene EPDM has an inter-ference at the 7.25-m (1379-cm1) peak and should bemeasured by Test Method A or C.5.2 Various commercial polymers h
17、ave interferences due toadditives and stabilizers that prevent or hinder the use of the8.65-m (1156-cm1) peak. Test Methods A and C should beapplied carefully, or Test Methods B and D should be used asdescribed in the procedure.5.3 Extender oil, when present, will interfere with alldeterminations an
18、d must be removed before infrared analysis.6. Apparatus6.1 Hydraulic Press, capable of 200 MPa (29 000 psi) and150C.6.2 Infrared Spectrophotometer, double-beam, having a per-cent transmission specification of 61 %, or better, at full scale,capable of recording a spectrum over the 2.5 to 15-m (4000 t
19、o667-cm1or 400 000 to 66 700-m1) region for Test MethodsA, B, and D. Test Method C requires an instrument capable ofrecording a spectrum over the 2.0 to 15-m (2000 to 667-cm1or 200 000 to 66 700-m1) region. Any spectrophotometercomplying with these requirements may be used. The equip-ment shall be o
20、perated by an experienced analyst according tothe manufacturers directions for optimum performance. Rec-ommended practices for general techniques of infrared quan-titative analysis are given in Practices E168.6.3 For routine testing, Fourier Transform Infrared (FT-IR)may be used in place of double b
21、eam instruments provided thebaseline calculation procedures in the Procedures and Calcu-lation Sections of each method are followed. Sample filmtemperature is lower with FT-IR than double beam instruments,and some partly crystalline polymers may respond differently.Calibration equations (Section 33)
22、 may have different math-ematical forms with FT-IR.7. Sampling7.1 Take precautions to ensure as representative a sample aspossible for spectral analysis, since infrared absorption isadditive in nature and will be influenced by extraneousmaterials.7.2 Where possible, take the sample from a freshly cu
23、tsurface to avoid testing of a partially oxidized polymer.8. Precision and Bias38.1 This precision and bias section has been prepared inaccordance with Practice D4483. Refer to Practice D4483 forterminology and other statistical calculation details.8.2 The precision results in this precision and bia
24、s sectiongive an estimate of the precision of these test methods with thematerials (rubbers) used in the particular interlaboratory pro-gram as described below. The precision parameters should notbe used for acceptance or rejection testing of any group ofmaterials without documentation that they are
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD39002005A2010STANDARDTESTMETHODSFORRUBBERDETERMINATIONOFETHYLENEUNITSINETHYLENEPROPYLENECOPOLYMERSEPMANDINETHYLENEPROPYLENEDIENETERPOLYMERSEPDMBYPDF

链接地址:http://www.mydoc123.com/p-515760.html