1、Designation: D 3652/D 3652M 01 (Reapproved 2006)Standard Test Method forThickness of Pressure-Sensitive Tapes1This standard is issued under the fixed designation D 3652/D 3652M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the d
3、etermination of the thick-ness of pressure-sensitive tapes at standard conditions.1.2 This test method is intended to replace AFERA 40062and PSTC 33.21.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exac
4、t equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the
5、user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D 996 Terminology of Packaging and Distribution Environ-mentsD 2904 Practice for Interlaboratory Testing of a
6、 Textile TestMethod that Produces Normally Distributed DataD 2906 Practice for Statements on Precision and Bias forTextilesD 3715/D 3715M Practice for Quality Assurance ofPressure-Sensitive TapesD 4332 Practice for Conditioning Containers, Packages, orPackaging Components for TestingE 122 Practice f
7、or Calculating Sample Size to Estimate,With a Specified Tolerable Error, the Average for aCharacteristic of a Lot or Process3. Terminology3.1 DefinitionsTerms found in Terminology D 996 shallapply.3.2 Definitions of Terms Specific to This Standard:3.2.1 thickness (caliper, gage)the perpendicular dis
8、tancebetween opposite surfaces of a tape expressed in mils 1/1000in.; usually measured under slight pressure with a specialgage.4. Significance and Use4.1 Thickness is an important property of tapes, and thisdimension is important for certain end uses. This test method isuseful for quality control a
9、nd for acceptance testing forconformance to specifications.5. Apparatus5.1 Cailper Gage, with the following requirements:5.1.1 Two plain faces, the smaller of which is circular and 8to 16 mm 0.32 to 0.64 in. in diameter. The faces shall beparallel to within 0.005 mm 0.0002 in. and constrained tomove
10、 apart along an axis perpendicular to them.5.1.2 When the specimen is placed between the faces, theforce should be such that the specimen shall be under a 50 to60 kPa 7.3 to 8.7 psi.5.1.3 The distance between the graduations on the dial shallbe such as to permit estimating the thickness to at least
11、0.002mm 0.0001 in.6. Sampling6.1 Acceptance SamplingSampling shall be in accordancewith Practice D 3715/D 3715M.6.2 Sampling for Other PurposesThe sampling and thenumber of test specimens depends on the purpose of testing.Practice E 122 is recommended. It is common to test at leastfive specimens of
12、a particular tape. Test specimens should betaken from several rolls of a tape and, whenever possible,1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.14 on Tape andLabels.Current edition approved April 1, 2006. Publish
13、ed April 2006. Originallyapproved in 1978. Last previous edition approved in 2001 as D 3652/D 3652M 01.2AFERA: Association des Fabricants de Rubans Auto-Adhesif; PSTC: PressureSensitive Tape Council (U.S.A.).3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custome
14、r Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.among several production runs of a tap
15、e. Strong conclusionsabout a specific property of a tape cannot be based on tests ofa single unit (roll) of product.7. Test Specimens7.1 The specimen width shall be greater than the diameter ofthe foot of the caliper gage and at least 50 mm 2 in. long. Itshall be free of wrinkles and creases.7.2 Unw
16、ind and discard at least three but no more than sixwraps of tape from the sample roll before taking specimens fortesting.7.3 Unless otherwise specified, remove one specimen persample roll for each test performed. Remove the specimenfrom a freely rotating roll at the rate of approximately 500 to750 m
17、m 20 to 30 in./s. Where width or other factors make itimpossible to remove the specimen at the prescribed rate,remove it at a rate as close to 500 mm 20 in./s as possible.8. Conditioning8.1 Condition sample rolls of tape in the standard condi-tioning atmosphere as described in Practice D 4332 for ap
18、eriod of not less than 24 h. Test at these conditions.9. Procedure9.1 Zero the instrument per manufacturers instructions.9.2 Place the specimen under the foot of the caliper gage,adhesive side up, and lower the the presser foot gently upon thesurface of the tape. Record the reading of the dial to th
19、e nearest0.002 mm 0.0001 in. one second after lowering the foot.Make three readings for each specimen. Average the readingsfor the thickness value of the specimen.9.3 To measure double-coated tapes with liner, measure thethickness of the specimen with one liner in place as in 9.2.Mark the liner wher
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD3652D3652M20012006STANDARDTESTMETHODFORTHICKNESSOFPRESSURESENSITIVETAPES 胶纸 厚度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-515187.html