ASTM D3539-1987(2004) Standard Test Methods for Evaporation Rates of Volatile Liquids by Shell Thin-Film Evaporometer《壳式薄膜蒸发计测定挥发性液体蒸发速率的试验方法》.pdf
《ASTM D3539-1987(2004) Standard Test Methods for Evaporation Rates of Volatile Liquids by Shell Thin-Film Evaporometer《壳式薄膜蒸发计测定挥发性液体蒸发速率的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3539-1987(2004) Standard Test Methods for Evaporation Rates of Volatile Liquids by Shell Thin-Film Evaporometer《壳式薄膜蒸发计测定挥发性液体蒸发速率的试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3539 87 (Reapproved 2004)Standard Test Methods forEvaporation Rates of Volatile Liquids by Shell Thin-FilmEvaporometer1This standard is issued under the fixed designation D 3539; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test me
3、thods cover the determination of the rateof evaporation of volatile liquids of low viscosity using theShell thin-film evaporometer. These test methods have beenapplied to a wide range of volatile liquids, including paint,varnish, and lacquer solvents and thinners to various hydrocar-bons and to inse
4、cticide spray-base oils.1.2 The test methods for the determination of evaporationrate using the thin-film evaporometer are:SectionsTest Method A2,3Manual Recording 5-11Test Method BAutomatic Recording 12-171.3 These test methods are limited only by the viscosity ofthe volatile liquid which must be s
5、ufficiently low to permit thedispensing of an accurately measured specimen from a syringe.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, asso
6、ciated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in 5.2 and 5.6.2. Referenced Documents2.1 ASTM Standards:4D 891
7、 Test Methods for Specific Gravity, Apparent, ofLiquid Industrial ChemicalsE 1 Specification for ASTM Liquid in Glass Thermometers3. Summary of Test Methods3.1 A known volume of liquid is spread on a known area offilter paper that is suspended from a sensitive balance in acabinet. Dried air or nitro
8、gen at 25C is passed through thecabinet at a known rate. The loss of weight of the filterpaper/liquid is determined and plotted against time.4. Significance and Use4.1 The rate of evaporation of volatile liquids from asolution or dispersion is important because it affects the rate ofdeposition of a
9、film and flow during deposition, and therebycontrols the structure and appearance of the film. In theformulation of paints and related products, solvents are chosenbased on the evaporation characteristics appropriate to theapplication technique and the curing temperature.1These test methods are unde
10、r the jurisdiction of ASTM Committee D01 onPaint and Related Coatings, Materials, and Applications and are the directresponsibility of Subcommittee D01.24 on Physical Properties of Liquid Paints andPaint Materials.Current edition approved July 1, 2004. Published July 2004. Originally approvedin 1976
11、. Last previous edition approved in 1996 as D 3539 76 (1996).2These test methods are essentially the same as the one developed by the NewYork Society for Paint Technology. The Precision section was added by ASTMSubcommittee D01.24 and is based upon the data of the New York Society for PaintTechnolog
12、y.3See “Comparative Evaporation Rates of Solvents: II,” New York Club,Technical Subcommittee No. 66, Offcial Digest, 28, No. 382, 1956, p. 1060.4For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards v
13、olume information, refer to the standards Document Summary page onthe ASTM website.FIG. 1 Details of the Thin-Film Evaporometer1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.TEST METHOD AEVAPORATION RATE USINGTHE MANUAL THIN-FILM EV
14、APOROMETER5. Apparatus5.1 Evaporometer, thin-film evaporometer5as shown inFig. 1 (see Annex A1).5.2 Constant-Temperature Cabinet for evaporometer.(WarningIn instances with the solvents and other volatilematerials normally tested using this apparatus and under theconditions specified in this test met
15、hod, the concentration ofsolvent or other flammable material being exhausted into thelaboratory atmosphere will be significantly below any concen-tration that could be hazardous, that is, a lower flammablelimit. However, it may be desirable to locate the instrument andcabinet in a laboratory exhaust
16、 hood if the routine handling ofcertain materials may present a hazard due to toxicity, extremevolatility, or flammability.)5.3 Interval Timer: Stopwatch or Electric TimerA timerthat gives an audible signal at 10 or 20-s intervals and thatgives a warning signal approximately 3 s before the end of th
17、einterval is preferred.5.4 Filter Paper DiskFast, open-textured filter paper, 90mm in diameter, with a circle approximately 60 mm indiameter (and concentric with the edge) lightly drawn on thepaper with a pencil.5.5 SyringeA 1.00-mL hypodermic syringe equipped witha 225-mm needle of 1.3-mm outside d
18、iameter stainless steeltubing.6Due to manufacturing variations, the syringe should becalibrated before use.5.6 Dehumidification EquipmentA suggested setup isgiven in a schematic diagram, Fig. 2. (WarningUse of thisdehumidification apparatus requires the safety practices rela-tive to the handling, us
19、e, and disposal of hazardous acids andcaustics be observed. When handling these materials, protec-tive eye or face shields, or both, and protective clothing arerecommended.)5.7 Hygrometer (or other humidity-sensing device), capableof indicating low humidities.5.8 Thermometers, of suitable accuracy s
20、uch as ASTMBomb Calorimeter thermometer 56C having a range from 19 to35C, subdivisions 0.02C or Thermometer 56F (66 to 95Fwith 0.05F subdivisions), and conforming to the requirementsof Specification E 1.6. Preparation of Evaporometer6.1 Place the filter paper disk on the wire support, threadingthe h
21、ook through a small hole in the center of the paper. Attachthe hook to the steel spring below the sighting disk and allowthe paper and the paper support to hang therefrom.6.2 Close the evaporometer and cabinet doors and allow thetemperature in both chambers and the humidity to equilibrate atthe foll
22、owing test conditions:Cabinet and evaporation temperature: 25 6 0.25C (77 6 0.5F)Evaporometer humidity: 0 to 5 % relative humidityApproximately 2 h are required for the humidity to drop toless than 5 %.6.3 Adjust the air flow to 21 L/min (center of ball floatopposite correct mark on the rotometer sc
23、ale).7. Conditioning7.1 Bring the sample or a portion of it to an equilibriumtemperature of 25 6 0.5C (77 6 1.0F) in a constant-temperature bath. Determine the specific gravity of the sampleat this temperature in accordance with Test Methods D 891.8. Procedure8.1 Record the position of the filter pa
24、per as indicated byalignment of the sighting disk with its mirror image. This is theno-load position.8.2 Raise the wire mesh bracket until the bottom of the disksupport rests lightly on it.8.3 Withdraw into the syringe 0.70 mL of the solvent whichis at 25 6 0.5C (77 6 1.0F). Make certain that all ai
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD353919872004STANDARDTESTMETHODSFOREVAPORATIONRATESOFVOLATILELIQUIDSBYSHELLTHINFILMEVAPOROMETER 薄膜

链接地址:http://www.mydoc123.com/p-514963.html