ASTM D3123-1998(2004) Standard Test Method for Spiral Flow of Low-Pressure Thermosetting Molding Compounds《低压热固性模塑料螺旋形流动的试验方法》.pdf
《ASTM D3123-1998(2004) Standard Test Method for Spiral Flow of Low-Pressure Thermosetting Molding Compounds《低压热固性模塑料螺旋形流动的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3123-1998(2004) Standard Test Method for Spiral Flow of Low-Pressure Thermosetting Molding Compounds《低压热固性模塑料螺旋形流动的试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3123 98 (Reapproved 2004)Standard Test Method forSpiral Flow of Low-Pressure Thermosetting MoldingCompounds1This standard is issued under the fixed designation D 3123; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers a procedure for measuring thespiral flow of thermosetting molding compounds (sof
3、t or verysoft) designed for molding pressures under 6.9 MPa 1000 psi.It is especially suited for those compounds that may be used forencapsulation or other low pressure molding techniques.Textile-reinforced compounds should not be tested using thistest method. It involves the use of a standard spira
4、l flow moldin a transfer molding press under specified conditions ofapplied temperature and pressure with a controlled chargemass.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establis
5、h appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no equivalent ISO standard.2. Referenced Documents2.1 ASTM Standards:2D 883 Terminology Relating to PlasticsD 958 Practice for Determining Temperatures of StandardASTM Mo
6、lds for Test Specimens of PlasticsE 105 Practice for Probability Sampling of Materials3. Terminology3.1 Definitions Definitions in this test method are consis-tent with Terminology D 883.4. Significance and Use4.1 The spiral flow of a thermosetting molding compound isa measure of the combined charac
7、teristics of fusion underpressure, melt viscosity, and gelation rate under specificconditions.4.2 This test method is useful as a quality control test and asan acceptance criterion.4.3 This test method, by itself, is not a valid means forcomparing the moldability of similar or different moldingcompo
8、unds because it cannot duplicate actual conditionsprevalent in different types of production molds.4.4 This test method is presently intended for use at atransfer pressure of 6.9 MPa 1000 psi and a mold temperatureof 423 6 3 K (150 6 3C 302 6 5F).5. Apparatus5.1 Transfer Molding Press with a minimum
9、 150 by150-mm 6 by 6-in. platen area, transfer piston pressurepotentially greater than 6.9 MPa 1000 psi, sufficient clamppressure to prevent flashing, and a minimum plunger speed of25.4 mm 1 in./s without load. The plunger should beequipped with at least one peripheral sealing groove. It isrecommend
10、ed that a pot diameter between 31.75 and 44.45 mm1.25 and 1.75 in. be used whenever a choice is possible.NOTE 2Preliminary evidence indicates that, in many cases, reason-able correlations may be achieved between laboratories using presses withdifferent pot diameters. Typical examples are presses wit
11、h pot diameters of31.750, 38.100, and 44.450 mm 1.250, 1.500, and 1.750 in. However, afew well-documented cases are recorded where differences in pot diam-eters, even within this listed range, have caused large differences inflow-length readings. Therefore, for best interlaboratory correlation it is
12、recommended that identical pot diameters be used.5.2 Standard Spiral-Flow Mold shown in Fig. 1 shall beutilized.6. Materials6.1 Molding Compound:6.1.1 Any thermosetting molding compound with a spiralflow between 762 and 1270 mm 30 and 50 in. as determinedat the standard temperature and pressure of t
13、his test can beevaluated.NOTE 3Since the only commercially available molds are calibrated ininches, spiral-flow length will be reported in these units. Conversion to SIunits can readily be made by multiplying the flow length, in inches, by theappropriate conversion factor, 25.4 mm/in.NOTE 4There is
14、considerable evidence that the test is usable over awider range of flow lengths, but this has not yet been confirmed byinterlaboratory testing.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.30 on Thermal Properties(Se
15、ction D20.30.08).Current edition approved October 1, 2004. Published December 2004. Originallyapproved in 1972. Last previous edition approved in 1999 as D 3123 - 98(99)e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
16、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.1.2 Fo
17、rmThe form of the molding compound shall beloose powder or granules at 296 6 2 K (23 6 2C 73.4 63.6F).NOTE 5Preforms or pellets may be used if found necessary; however,flow length may be affected by their use.7. Sampling7.1 Unless otherwise agreed upon between the seller andpurchaser, sampling shall
18、 be in accordance with PracticeE 105. Sampling, based on engineering principles, prior topackaging shall be considered an acceptable alternative.8. Conditioning8.1 ConditioningAll molding compounds shall be testedin “as-received” condition. For referee testing, all materialshall be shipped and store
19、d in moisture-barrier containers.They shall be stored for a minimum of 24 h at the standardlaboratory temperature, before breaking the seal on the con-tainer. Care should be taken to preserve the “as-received”moisture content and tests shall be made as soon as possibleonce the container has been ope
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD312319982004STANDARDTESTMETHODFORSPIRALFLOWOFLOWPRESSURETHERMOSETTINGMOLDINGCOMPOUNDS 低压 热固性 塑料

链接地址:http://www.mydoc123.com/p-514107.html