ASTM D3084-2005(2012) Standard Practice for Alpha-Particle Spectrometry of Water 《水的α-粒子光谱测定法的标准实施规程》.pdf
《ASTM D3084-2005(2012) Standard Practice for Alpha-Particle Spectrometry of Water 《水的α-粒子光谱测定法的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3084-2005(2012) Standard Practice for Alpha-Particle Spectrometry of Water 《水的α-粒子光谱测定法的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3084 05 (Reapproved 2012)Standard Practice forAlpha-Particle Spectrometry of Water1This standard is issued under the fixed designation D3084; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the processes that are required toobtain well-resolved alpha-particle spectra from water samplesand discusses as
3、sociated problems. This practice is generallycombined with specific chemical separations, mounting tech-niques, and counting instrumentation, as referenced.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of
4、 this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C859 Terminology Relating to Nuclear MaterialsC1163 Practice for Mounting Actinides for Alpha Spec-trometry Using Ne
5、odymium FluorideD1129 Terminology Relating to WaterD3648 Practices for the Measurement of RadioactivityD3865 Test Method for Plutonium in WaterD3972 Test Method for Isotopic Uranium in Water byRadiochemistry3. Terminology3.1 For definitions of terms used in this practice, refer toTerminologies D1129
6、 and C859. For terms not found in theseterminologies, reference may be made to other publishedglossaries (1, 2).34. Summary of Practice4.1 Alpha-particle spectrometry of radionuclides in water(also called alpha-particle pulse-height analysis) has beencarried out by several methods involving magnetic
7、 spectrom-eters, gas counters, scintillation spectrometers, nuclear emul-sion plates, cloud chambers, absorption techniques, and solid-state counters. Gas counters, operating either as an ionizationchamber or in the proportional region, have been widely usedto identify and measure the relative amoun
8、ts of differenta-emitters. However, more recently, the solid-state counter hasbecome the predominant system because of its excellentresolution and compactness. Knoll (3) extensively discussesthe characteristics of both detector types.4.2 Of the two gas-counting techniques, the pulsed ioniza-tion cha
9、mber is more widely used as it gives much betterresolution than does the other. This is because there is nospread arising from multiplication or from imperfection of thewire such as occurs with the proportional counter.4.3 The semiconductor detectors used for alpha-particlespectrometry are similar i
10、n principle to ionization chambers.The ionization of the gas by a-particles gives rise to electron-ion pairs, while in a semiconductor detector, electron-holepairs are produced. Subsequently, the liberated changes arecollected by an electric field. In general, silicon detectors areused for alpha-par
11、ticle spectrometry. These detectors are n-typebase material upon which gold is evaporated or ions such asboron are implanted, making an electrical contact. A reversedbias is applied to the detector to reduce the leakage current andto create a depletion layer of free-charge carriers. This layer isthi
12、n and the leakage current is very low. Therefore, the slightinteractions of photons with the detector produce no signal.The effect of any interactions of beta particles with the detectorcan be eliminated by appropriate electronic discrimination(gating) of signals entering the multichannel analyzer.
13、Asemiconductor detector detects all alpha particles emitted byradionuclides (approximately 2 to 10 MeV) with essentiallyequal efficiency, which simplifies its calibration.4.4 Semiconductor detectors have better resolution than gasdetectors because the average energy required to produce anelectron-ho
14、le pair in silicon is 3.5 6 0.1 eV (0.56 6 0.02 aJ)compared with from 25 to 30 eV (4.0 to 4.8 aJ) to produce anion pair in a gas ionization chamber. Detector resolution,defined as peak full-width at half-maximum height (FWHM),is customarily expressed in kiloelectron-volts. The FWHMincreases with inc
15、reasing detector area, but is typically be-tween 15 and 60 keV. The background is normally lower for asemiconductor detector than for ionization chamber. Silicon1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.04 on Methods o
16、f RadiochemicalAnalysis.Current edition approved June 1, 2012. Published August 2012. Originallyapproved in 1972. Last previous edition approved in 2005 as D3084 05. DOI:10.1520/D3084-05R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at servi
17、ceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The boldface numbers in parentheses refer to the list of references at the end ofthis document.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Con
18、shohocken, PA 19428-2959, United States.detectors have four other advantages compared to ionizationchambers: they are lower in cost, have superior stability, havehigher permissible counting rates, and have better time reso-lution for coincidence measurements. However, the semicon-ductor detector req
19、uires sophisticated electronics because ofthe low charge that is generated by the incident a-particle inthe detector. Low-noise and high-stability, charge-sensitivepreamplifiers are used prior to the detection, analog-to-digitalconversion, and storage of the voltage pulse by a multichannelanalyzer.
20、The counting is nearly always performed in a vacuumchamber so that thea -particles will not lose energy bycollisions with air molecules between the source and thedetector.4.5 A gridded pulse-ionization chamber was developed byFrisch for high-resolution alpha spectrometry. The unit consistsof a stand
21、ard ionization chamber fitted with a collimatorbetween the source and the collector plate and a wire grid toshield the collector from the effects of positive ions. Theresolution of a gridded pulse ionization chamber is from 35 to100 keV for routine work. The detector parameters that affectresolution
22、 are primarily the following: statistical variations inthe number of ion pairs formed at a given alpha energy, thevariation in rise time of pulses, and the effects of positive ions.An advantage of gridded ionization chambers is their ability tocount large-area sources with good efficiency.4.6 There
23、are two reasons for collimating a sample in agridded ionization chamber. When thick-sample sources areencountered, the alpha-particles emitted at a large solid anglewould show an energy degradation upon ionization of the gas.The effect leads to tailing of the alpha-particle spectrum. Thisproblem is
24、reduced significantly by use of the collimator.Secondly, when the nucleus following ana -particle emissiondoes not decay to a ground state, the g-rays that may beproduced are usually highly converted, and the conversionelectrons ionize the gas. The special mesh-type collimatorsstop the conversion el
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD308420052012STANDARDPRACTICEFORALPHAPARTICLESPECTROMETRYOFWATER 粒子 光谱 测定法 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-514060.html