ASTM D2902-2000(2006) Standard Specification for Fluoropolymer Resin Heat-Shrinkable Tubing for Electrical Insulation《电绝缘用含氟聚合物树脂热收缩管的标准规范》.pdf
《ASTM D2902-2000(2006) Standard Specification for Fluoropolymer Resin Heat-Shrinkable Tubing for Electrical Insulation《电绝缘用含氟聚合物树脂热收缩管的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2902-2000(2006) Standard Specification for Fluoropolymer Resin Heat-Shrinkable Tubing for Electrical Insulation《电绝缘用含氟聚合物树脂热收缩管的标准规范》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2902 00 (Reapproved 2006)An American National StandardStandard Specification forFluoropolymer Resin Heat-Shrinkable Tubing for ElectricalInsulation1This standard is issued under the fixed designation D 2902; the number immediately following the designation indicates the year oforigina
2、l adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification applies to flexible heat-shrinkableextruded tu
3、bing made from tetrafluoroethylene resin, copoly-mer of tetrafluoroethylene and hexafluoropropylene, and fromperfluoroalkoxy resin for use as electrical insulation.NOTE 1This standard is similar but not identical to IEC 606843240to 243.1.2 The values stated in inch-pound units are to be regardedas t
4、he standard except temperature which shall be stated indegrees Celsius. Values in parentheses are for information only.2. Referenced Documents2.1 ASTM Standards:2C 618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteD 638 Test Method for Tensile Properties of Pl
5、asticsD 1711 Terminology Relating to Electrical InsulationD2116 Specification for FEP-Fluorocarbon Molding andExtrusion MaterialsD 2671 Test Methods for Heat-Shrinkable Tubing for Elec-trical UseD 3307 Specification for Perfluoroalkoxy (PFA)-Fluorocarbon Resin Molding and Extrusion MaterialsD 3636 P
6、ractice for Sampling and Judging Quality of SolidElectrical Insulating MaterialsD 4895 Specification for Polytetrafluoroethylene (PTFE)Resin Produced From DispersionE 176 Terminology of Fire Standards2.2 IEC Standards:606843240 to 243 Flexible insulating sleeving, Part 3,Sheets 240 to 243: Heat-shri
7、nkable PTFE sleeving33. Terminology3.1 Definitions:3.1.1 For definitions pertaining to electrical insulation, referto Terminology D 1711.3.1.2 For definitions pertaining to fire standards, refer toTerminology E 176.4. Classification4.1 Type ITubing made from tetrafluoroethylene polymer(TFE) and capa
8、ble of being heat shrunk at a temperature of 327C 621 F.4.2 Type IITubing made from a copolymer of tetrafluo-roethylene and hexafluoropropylene (FEP) and capable ofbeing heat shrunk at a temperature of 150 C 302 F.4.3 Type IIITubing made from perfluoroalkoxy resin(PFA) and capable of being heat shru
9、nk at a temperature of 175C 347 F.5. Ordering Information5.1 When ordering to this specification, the purchaser muststate the size, and type of the required tubing.6. Materials and Manufacture6.1 The compound used in the manufacture of this tubingshall be modified fluoropolymer resin, and the finish
10、ed com-pound shall be free of all foreign matter other than intendedformulation additives as appropriate.6.2 Type I tubing is normally made by paste extrusion. TypeII and Type III tubings are normally made by melt extrusion.All types are expanded by mechanical means.7. Chemical and Physical Property
11、 Requirements7.1 The material shall conform to the chemical and physicalproperty requirements specified in Table 1.1This specification is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.07 on Flexible a
12、nd Rigid Insulating Materials.Current edition approved April 1, 2006. Published April 2006. Originallyapproved in 1970. Last previous edition approved in 2000 as D 2902 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
13、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohock
14、en, PA 19428-2959, United States.7.2 Every lot of material manufactured should be tested fordimensional requirements and restricted shrinkage. Other re-quirements may be tested less frequently or with a frequencyagreed upon between seller and purchaser.8. Dimensional Requirements8.1 Type I material
15、shall conform to the requirementsspecified in Table 3.TABLE 3 Dimensions, Type ILengths for Type IAs Supplied After Unrestrictive ShrinkageStock Lengths PackagingInside Diameter, min, in. mm Inside Diameter, max, in. mm Wall Thickness, in. mmHeavy Wall0.166 4.22 0.130 3.30 0.0306 0.005 0.76 6 0.13 3
16、 ft to 1 ft min straight lengths0.250 6.35 0.193 4.90 0.0306 0.005 0.76 6 0.13 3 ft to 1 ft min straight lengths0.333 8.46 0.257 6.53 0.0306 0.005 0.76 6 0.13 3 ft to 1 ft min straight lengths0.415 10.54 0.320 8.13 0.0306 0.005 0.76 6 0.13 3 ft to 1 ft min straight lengths0.498 12.65 0.383 9.73 0.03
17、06 0.005 0.76 6 0.13 3 ft to 1 ft min straight lengthsTABLE 1 Chemical and Physical Property RequirementsPropertyRequirementType I Type II Type IIIRestricted shrinkage,AProcedure B, 2000 V, 10 min no cracking no cracking no crackingSpecific gravity 2.13 to 2.18 2.12 to 2.20 2.13 to 2.20Longitudinal
18、change, max, % + 20 615 615Tensile modulus at 200 % elongation, min, psi MPa Test Method D 6382 in./min 50 mm/min2000 13.8 1500 10.3 2500 17.3Volume resistivityB, ohm-cm, at standard laboratory atmosphere, min 101610161016Dielectric breakdown voltage, min kV:Wall thickness 0.004 to 0.006 in. 8 8 80.
19、007 to 0.008 in. 10 10 100.009 in. 11.5 11.5 11.50.010 to 0.011 in. 12.5 12.5 12.50.012 to 0.014 in. 14.6 14.6 14.60.015 in. 15 15 150.016 to 0.019 in. 16.3 16.3 16.30.020 in. and larger 17 17 17Heat resistance: for 96 h followed by tests for tensile modulus at200 % elongation, min, psi MPaType I350
20、 6 4C6626 7 F 2000 13.8Type II250 6 3C4826 6 F 1500 10.3Type III275 6 4C5276 7 F 2500 17.3Low-temperature flexibility, 556 2C676 4 F no cracking no cracking no crackingMelting point:Specification D 4895 327 6 10 C6216 20 FSpecification D2116 270 6 20 C518 6 40 FSpecification D 3307 endotherm peak, m
21、in 300 6 2C572 6 7FSpecification D 3307 305 6 3C5816 5FAFor over-expanded sleeving, use a mandrel equal to the enclosable diameters (D + d)/2.BSee Specification C 618.TABLE 2 Mandrel Sizes for Low-Temperature Flexibility TestingNominal Tubing InsideDiameter (max afterunrestricted shrinkage)Mandrel D
22、iameter,in. mm in. mm0.015 to 0.125 0.38 to 3.2 0.3125 6 0.002 7.956 0.060.126 to 0.250 3.3 to 6.3 0.375 6 0.003 8.066 0.070.251 to 1.000 6.4 to 26 0.437 6 0.004 11.106 0.101.001 to 2.000 27 to 50 0.875 6 0.005 16.13 6 0.132.001 to 3.000 51 to 75 1.000 6 0.005 25.40 6 0.133.001 to 4.000 76 to 101 1.
23、125 6 0.005 28.586 0.13D 2902 00 (2006)2TABLE 3 ContinuedAs Supplied After Unrestrictive ShrinkageStock Lengths PackagingInside Diameter, min, in. mm Inside Diameter, max, in. mm Wall Thickness, in. mm0.580 14.73 0.448 11.38 0.0306 0.005 0.76 6 0.13 3 ft to 1 ft min straight lengths0.666 16.92 0.510
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD290220002006STANDARDSPECIFICATIONFORFLUOROPOLYMERRESINHEATSHRINKABLETUBINGFORELECTRICALINSULATION

链接地址:http://www.mydoc123.com/p-513769.html