ASTM D2158-2005 Standard Test Method for Residues in Liquefied Petroleum (LP) Gases《液化石油(LP)气中残留物的标准测试方法》.pdf
《ASTM D2158-2005 Standard Test Method for Residues in Liquefied Petroleum (LP) Gases《液化石油(LP)气中残留物的标准测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2158-2005 Standard Test Method for Residues in Liquefied Petroleum (LP) Gases《液化石油(LP)气中残留物的标准测试方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2158 05Designation: 317/95An American National StandardStandard Test Method forResidues in Liquefied Petroleum (LP) Gases1This standard is issued under the fixed designation D 2158; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of extraneousmaterials weathering above 38C that
3、 are present in liquefiedpetroleum gases. The extraneous materials will generally bedissolved in the LPG, but may have phase-separated in someinstances.1.2 Liquefied petroleum gases that contain certain anti-icingadditives can give erroneous results by this test method.1.3 Although this test method
4、has been used to verifycleanliness and lack of heavy contaminants in propane formany years, it might not be sensitive enough to protect someequipment from operational problems or increased mainte-nance. A more sensitive test, able to detect lower levels ofdissolved contaminants, could be required fo
5、r some applica-tions.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior t
6、o use.2. Referenced Documents2.1 ASTM Standards:2D96 Test Methods for Water and Sediment in Crude Oil byCentrifuge Method (Field Procedure)3D 1796 Test Method forWater and Sediment in Fuel Oils bythe Centrifuge Method (Laboratory Procedure)D 1835 Specification for Liquefied Petroleum (LP) GasesE1 Sp
7、ecification for ASTM Liquid-in-Glass Thermometers2.2 Other Document:IP Appendix A43. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 oil stain observation, nthe volume of solvent-residue mixture required to yield an oil stain or ring thatpersists for 2 minutes under specified con
8、ditions on absorbentpaper.3.1.2 residue, nthe volume, measured to the nearest 0.05mL, of the residual material boiling above 38C resulting fromthe evaporation of 100 mL of sample under the specifiedconditions of this test method.3.1.3 solvent-residue mixture, na mixture (solution) of 10mL of solvent
9、 with any residue remaining in the centrifugetube at the conclusion of the first step in this test method.4. Summary of Test Method4.1 A 100-mL sample of liquefied petroleum gas is weath-ered in a 100-mL centrifuge tube. The volume of residueremaining after heating the tube to 38C is measured andrec
10、orded.4.2 To dissolve any residue, 10 mLof solvent is added to thecentrifuge tube. Small, measured volumes of solvent-residuemixture are deposited on an absorbent paper in a specifiedmanner. The appearance of the absorbent paper to which theresidue solution has been added in measured increments isob
11、served and recorded.5. Significance and Use5.1 Control over the residue content (required by Specifica-tion D 1835) is of considerable importance in end-use appli-cations of LPG. In liquid feed systems residues can lead totroublesome deposits and, in vapor withdrawal systems, resi-dues that are carr
12、ied over can foul regulating equipment. Those1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.H0 on Liquefied Petroleum Gas.Current edition approved Nov. 1, 2005. Published November 2005. Origina
13、llyapproved in 1963. Last previous edition approved in 2004 as D 215804.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe AS
14、TM website.3Withdrawn.4Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR,U.K. www.energyinstpubs.org.uk1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United St
15、ates.that remain will accumulate, can be corrosive, and willcontaminate following product. Water, particularly if alkaline,can cause failure of regulating equipment and corrosion ofmetals.6. Interferences6.1 Solid contaminants such as rust, scale or dirt caninterfere with this test method, which is
16、not intended forrepresentative measurement of solid, undissolved contami-nants.7. Apparatus7.1 Centrifuge Tube, 100-mL graduated, conforming todimensions given in Fig. 1. The first 0.5 mL shall be graduatedin 0.05-mL increments. The shape of the lower tip of the tubeis especially important. The tape
17、r shall be uniform and thebottom shall be rounded as shown in Fig. 1. Tubes shall bemade of thoroughly annealed heat-resistant glass. Volumetricgraduation tolerances, based on air-free water at 20C, aregiven in Table 1. Detailed requirements for centrifuge tubesappear in Test Methods D96and D 1796.7
18、.2 Cooling Coil and Cooling Bath, a minimum length of 6m of 5 to 7-mm outside diameter copper tubing wound to adiameter of 63.5 6 1.5-mm outside diameter, and assembled ina suitable cooling bath. (See Fig. 2 as an example.)7.2.1 Mechanical refrigeration is permitted provided thatthe coolant temperat
19、ure is below 43C. If dry ice is used, anon-glass dewar or vessel is recommended.7.3 Syringe, 2-mL graduated in 0.1 mL and equipped with aneedle 200 6 5 mm long. The needle may be either a sharpFIG. 1 Cone-Shaped Centrifuge Tube, 203 mmD2158052needle (ordinary medical syringe needle) or a safe, non-s
20、harpsyringe needle to avoid a puncture hazard. Alternatively, anequivalent liquid dispensing device capable of delivering0.1-mL increments may be used, such as a 0.1-mL pipette.7.4 Temperature Measuring Device, that is intrinsicallysafe, with accuracy equal to or better than Specification E1orIP App
21、endix A shall be used. Thermometers conforming toSpecification E1or IP Appendix A have been found to besatisfactory.Low Range 38C to + 50C IP 1C/ASTM 5Cor IP 2C/ASTM 6CHigh Range 20C to + 50C ASTM 57CNOTE 1When a thermometer or a water bath, or both, are notavailable, for example when conducting a f
22、ield test, a satisfactoryalternative for screening purposes is to warm the tip of the centrifuge tubewith the hand.7.4.1 For routine testing, a general purpose thermometerwith 0.5C subdivisions and a maximum scale error of 0.5Cmay be used.7.5 Absorbent Paper, white, 125-mm diameter. Mediumgrade, rap
23、id filter paper has been found to be satisfactory. Inthis test method, the paper will be referred to as “filter paper.”7.6 Solvent Wash Bottle, typically polyethylene.7.7 Water Bath, controlled at 38 6 2C.7.8 Copper Wire, 1.6 6 0.1-mm diameter, 300 6 10-mmlong.7.9 Clamp, suitable for holding the cen
24、trifuge tube duringweathering.8. Reagents and Materials8.1 SolventHPLC-grade pentane or cyclopentane. An-other grade of solvent may be used provided that it meets therequirements of 10.2.8.1.1 Although pentane is the preferred solvent for use inthis test method, cyclopentane may be substituted for p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD21582005STANDARDTESTMETHODFORRESIDUESINLIQUEFIEDPETROLEUMLPGASES 液化 石油 LP 残留物 标准 测试 方法 PDF

链接地址:http://www.mydoc123.com/p-511102.html