1、Designation: D1499 13Standard Practice forFiltered Open-Flame Carbon-Arc Exposures of Plastics1This standard is issued under the fixed designation D1499; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This practice covers specific procedures and test con
3、di-tions that are applicable for exposure of plastics in filteredopen-flame carbon-arc devices conducted in accordance withPractices G151 and G152. This practice also covers thepreparation of test specimens, the test condition suited forplastics, and the evaluation of test results.1.2 This practice
4、does not cover enclosed carbon-arc expo-sures of plastics, which had been allowed in Practice D1499.Enclosed carbon-arc exposures of plastics are described inPractice D6360, and in G153, which gives requirements forexposing nonmetallic materials in enclosed carbon-arc devices.1.3 The values stated i
5、n SI units are to be regarded asstandard. The values in parentheses are given for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health
6、 practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1This practice is technically equivalent to ISO 4892-4.2. Referenced Documents2.1 ASTM Standards:2D3980 Practice for Interlaboratory Testing of Paint andRelated Materials (Withdrawn 1998)3D5870 Practice for Calcu
7、lating Property Retention Index ofPlasticsD6360 Practice for Enclosed Carbon-Arc Exposures of Plas-ticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodG113 Terminology Relating to Natural and Artificial Weath-ering Tests of Nonmetallic MaterialsG141 Gu
8、ide for Addressing Variability in Exposure Testingof Nonmetallic MaterialsG147 Practice for Conditioning and Handling of Nonmetal-lic Materials for Natural and Artificial Weathering TestsG151 Practice for Exposing Nonmetallic Materials in Accel-erated Test Devices that Use Laboratory Light SourcesG1
9、52 Practice for Operating Open Flame Carbon Arc LightApparatus for Exposure of Nonmetallic MaterialsG153 Practice for Operating Enclosed Carbon Arc LightApparatus for Exposure of Nonmetallic MaterialsG169 Guide for Application of Basic Statistical Methods toWeathering Tests2.2 ISO Standard:4ISO 4892
10、-4 PlasticsMethods of Exposure to LaboratoryLight SourcesPart 4, Open-Flame Carbon Arc Lamp3. Terminology3.1 The definitions in Terminology G113 are applicable tothis practice.4. Significance and Use4.1 The ability of a plastic material to resist deterioration ofits electrical, mechanical, and optic
11、al properties caused byexposure to light, heat, and water can be very significant formany applications. This practice is intended to induce propertychanges associated with end-use conditions, including theeffects of sunlight, moisture, and heat. The exposure used inthis practice is not intended to s
12、imulate the deterioration causedby localized weather phenomena, such as, atmosphericpollution, biological attack, and saltwater exposure.4.2 CautionsVariation in results may be expected whenoperating conditions are varied within the accepted limits ofthis practice. Therefore, no reference to the use
13、 of this practiceshall be made unless accompanied by a report prepared inaccordance with Section 9 that describes the specific operating1This practice is under the jurisdiction ofASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.50 on Durability of Plastics.Current e
14、dition approved July 15, 2013. Published August 2013. Originallyapproved in 1950. Last previous edition approved in 2005 as D1499 - 05. DOI:10.1520/D1499-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of AS
15、TMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.*A Summary of
16、 Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1conditions used. Refer to Practice G151 for detailed informa-tion on the caveats applicable to use of results obtained inaccordance wi
17、th this practice.NOTE 2Additional information on sources of variability and onstrategies for addressing variability in the design, execution, and dataanalysis of laboratory-accelerated exposure tests is found in Guide G141.4.2.1 The spectral power distribution of light from anopen-flame carbon-arc i
18、s significantly different from thatproduced in light and water exposure devices using othercarbon-arc configurations or other light sources. The type andrate of degradation and the performance rankings produced byexposures to filtered open-flame carbon-arcs can be muchdifferent from those produced b
19、y exposures to other types oflaboratory light sources.4.2.2 Interlaboratory comparisons are valid only when alllaboratories use the same type of carbon-arc, filters, andexposure conditions.4.3 Reproducibility of test results between laboratories hasbeen shown to be good when the stability of materia
20、ls isevaluated in terms of performance ranking compared to othermaterials or to a control.5,6Therefore, exposure of a similarmaterial of known performance (a control) at the same time asthe test materials is strongly recommended. It is recommendedthat at least three replicates of each material be ex
21、posed toallow for statistical evaluation of results.4.4 Test results will depend upon the care that is taken tooperate the equipment in accordance with Practice G152.Significant factors include regulation of line voltage, freedomfrom salt or other deposits from water, temperature andhumidity control
22、, and conditions of the electrodes.5. Apparatus5.1 Use filtered open-flame carbon-arc apparatus that con-forms to the requirements defined in Practices G151 and G152.5.2 Unless otherwise specified, the spectral power distribu-tion of the filtered open-flame carbon-arc shall conform to therequirement
23、s in Practice G152 for carbon-arc with daylightfilters.6. Test Specimen6.1 The size and shape of specimens to be exposed will bedetermined by the specifications of the particular test methodused to evaluate the effects of the exposure on the specimens;the test method shall be determined by the parti
24、es concerned.Where practical, it is recommended that specimens be sized tofit specimen holders and racks supplied with the exposureapparatus. Unless supplied with a specific backing as anintegral part of the test, specimens shall be mounted so thatonly the minimum specimen area required for support
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD14992013STANDARDPRACTICEFORFILTEREDOPENFLAMECARBONARCEXPOSURESOFPLASTICS 塑料 滤光 明火 碳弧型 曝光 装置 标准 实施

链接地址:http://www.mydoc123.com/p-509905.html