ASTM D1499-2005 Standard Practice for Filtered Open-Flame Carbon-Arc Exposures of Plastics《塑料用滤光明火碳弧型曝光装置的标准实施规程》.pdf
《ASTM D1499-2005 Standard Practice for Filtered Open-Flame Carbon-Arc Exposures of Plastics《塑料用滤光明火碳弧型曝光装置的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1499-2005 Standard Practice for Filtered Open-Flame Carbon-Arc Exposures of Plastics《塑料用滤光明火碳弧型曝光装置的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1499 05Standard Practice forFiltered Open-Flame Carbon-Arc Exposures of Plastics1This standard is issued under the fixed designation D 1499; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers specific procedures and test condi-tions that are applicable for exposure of plastics in filteredopen-flame ca
3、rbon-arc devices conducted in accordance withPractices G 151 and G 152. This practice also covers thepreparation of test specimens, the test condition suited forplastics, and the evaluation of test results.1.2 This practice does not cover enclosed carbon-arc expo-sures of plastics, which had been al
4、lowed in Practice D 1499.Enclosed carbon-arc exposures of plastics are described inPractice D 6360, and in G 153, which gives requirements forexposing nonmetallic materials in enclosed carbon-arc devices.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with
5、 its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1This practice is technically equivalent to ISO 4892-4.2. Referenced Documents2.1 ASTM Standards:2D 3980 P
6、ractice for Interlaboratory Testing of Paint andRelated MaterialsD 5870 Practice for Calculating Property Retention Indexof PlasticsD 6360 Practice for Enclosed Carbon-Arc Exposures ofPlasticsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodG113 Termin
7、ology Relating to Natural and ArtificialWeathering Tests of Nonmetallic MaterialsG 141 Guide forAddressing Variability in Exposure Testingon Nonmetallic MaterialsG 147 Practice for Conditioning and Handling of Nonme-tallic Materials for Natural and Artificial Weathering TestsG 151 Practice for Expos
8、ing Nonmetallic Materials in Ac-celerated Test Devices That Use Laboratory Light SourcesG 152 Practice for Operating Open-Flame Carbon-ArcLight Apparatus for Exposure of Nonmetallic MaterialsG 153 Practice for Operating Enclosed Carbon-Arc LightApparatus for Exposure of Nonmetallic MaterialsG 169 Gu
9、ide forApplication of Basic Statistical Methods toWeathering Tests2.2 ISO Standard:3ISO 4892-4 PlasticsMethods of Exposure to LaboratoryLight SourcesPart 4, Open-Flame Carbon Arc Lamp3. Terminology3.1 The definitions in Terminology G113are applicable tothis practice.4. Significance and Use4.1 The ab
10、ility of a plastic material to resist deterioration ofits electrical, mechanical, and optical properties caused byexposure to light, heat, and water can be very significant formany applications. This practice is intended to induce propertychanges associated with end-use conditions, including theeffe
11、cts of sunlight, moisture, and heat. The exposure used inthis practice is not intended to simulate the deterioration causedby localized weather phenomena, such as, atmospheric pollu-tion, biological attack, and saltwater exposure. (WarningVariation in results may be expected when operating condition
12、sare varied within the accepted limits of this practice. Therefore,no reference to the use of this practice shall be made unlessaccompanied by a report prepared in accordance with Section9 that describes the specific operating conditions used. Refer toPractice G 151 for detailed information on the c
13、aveats appli-cable to use of results obtained in accordance with thispractice.)NOTE 2Additional information on sources of variability and onstrategies for addressing variability in the design, execution, and dataanalysis of laboratory-accelerated exposure tests is found in Guide G 141.4.2 Reproducib
14、ility of test results between laboratories hasbeen shown to be good when the stability of materials is1This practice is under the jurisdiction ofASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.50 on Permanence Properties.Current edition approved July 1, 2005. Publi
15、shed July 2005. Originally approvedin 1950. Last previous edition approved in 1999 as D 1499 - 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docu
16、ment Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 1
17、9428-2959, United States.evaluated in terms of performance ranking compared to othermaterials or to a control.4,5Therefore, exposure of a similarmaterial of known performance (a control) at the same time asthe test materials is strongly recommended. It is recommendedthat at least three replicates of
18、 each material be exposed toallow for statistical evaluation of results.4.3 Test results will depend upon the care that is taken tooperate the equipment in accordance with Practice G 152.Significant factors include regulation of line voltage, freedomfrom salt or other deposits from water, temperatur
19、e andhumidity control, and conditions of the electrodes.5. Apparatus5.1 Use filtered open-flame carbon-arc apparatus that con-forms to the requirements defined in Practices G 151 andG 152.5.2 Unless otherwise specified, the spectral power distribu-tion of the filtered open-flame carbon-arc shall con
20、form to therequirements in Practice G 152 for carbon-arc with daylightfilters.6. Test Specimen6.1 The size and shape of specimens to be exposed will bedetermined by the specifications of the particular test methodused to evaluate the effects of the exposure on the specimens;the test method shall be
21、determined by the parties concerned.Where practical, it is recommended that specimens be sized tofit specimen holders and racks supplied with the exposureapparatus. Unless supplied with a specific backing as anintegral part of the test, specimens shall be mounted so thatonly the minimum specimen are
22、a required for support by theholder shall be covered. This unexposed surface must not beused as part of the test area. When necessary, to providerigidity, flexible specimens should be attached to, or backed by,a panel made of aluminum, 0.025-in 0.64-mm thick.6.2 Unless otherwise specified, expose at
23、 least three repli-cate specimens of each test and control material.6.3 Retain a supply of unexposed file specimens of allmaterial evaluated.6.3.1 When destructive tests are run, ensure that sufficientfile specimens are retained so that the property of interest canbe determined on unexposed file spe
24、cimens each time exposedmaterials are evaluated.6.4 Specimens should not be removed from the exposureapparatus for more than 24 h and then returned for additionaltests, since this does not produce the same results on allmaterials as tests run without this type of interruption. Whenspecimens are remo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD14992005STANDARDPRACTICEFORFILTEREDOPENFLAMECARBONARCEXPOSURESOFPLASTICS 塑料 滤光 明火 碳弧型 曝光 装置 标准 实施

链接地址:http://www.mydoc123.com/p-509904.html