ASTM D1287-2009 Standard Test Method for pH of Engine Coolants and Antirusts《发动机冷却剂和防锈剂的pH值的标准试验方法》.pdf
《ASTM D1287-2009 Standard Test Method for pH of Engine Coolants and Antirusts《发动机冷却剂和防锈剂的pH值的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1287-2009 Standard Test Method for pH of Engine Coolants and Antirusts《发动机冷却剂和防锈剂的pH值的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1287 09Standard Test Method forpH of Engine Coolants and Antirusts1This standard is issued under the fixed designation D1287; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pare
2、ntheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the determination of the pH ofunused engine
3、coolants and antirusts, and used or unusedaqueous dilutions of the concentrated products.NOTE 1Antirusts in solid form are not included in this test method.NOTE 2It is believed that this procedure gives all the informationrequired for determining the pH of samples of engine coolant or antirustlikely
4、 to be encountered. Should additional information on pH determi-nations be needed, reference should be made to Test Method E70.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish a
5、ppro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1176 Practice for Sampling and Preparing Aqueous Solu-tions of Engine Coolants or Antirusts for Testing PurposesE70 Test Method for pH of Aqueou
6、s Solutions With theGlass Electrode3. Summary of Test Method3.1 A sample, as received or after dilution with a specifiedvolume of distilled water, is placed in a beaker or sample cupand the pH measured with a pH meter and combinationelectrode or associated glass-saturated calomel electrode pair.NOTE
7、 3The readings of the meter in the case of the concentratedproducts are not pH values according to the accepted definition, but areapparent pH values which are useful in the interpretation of the conditionof the product.4. Significance and Use4.1 pH is a measure of the hydrogen ion concentration and
8、indicates whether an engine coolant, antirust, or a solution ofthese compounds is acidic, alkaline, or neutral.4.2 The pH range includes values from 0 to 14. Values from0 to 7 represent the acidic half of the scale. Values from 7 to 14represent the alkaline or basic half of the scale. The pH value7
9、is considered neutral, as it is neither acidic nor alkaline.4.3 pH is sometimes used for production quality control. Itis generally desirable that engine coolants have an alkaline pH.4.4 pH is not significant from the standpoint of predictingservice life. The pH of used engine coolants or antirustso
10、lutions is not a dependable indication of either existingeffectiveness or remaining life of the solution.5. Apparatus5.1 The pH meter, glass electrode, and calomel electrode,shall be as specified in the Annex.NOTE 4In pH operation, the meter may be set up to perform one-,two- or up to five-point sta
11、ndardizations or may be set up to automaticallyrecognize U.S. standard (pH 4, 7 and 10) buffers, NIST/International (pH1.68, 4.01, 6.86, 9.18 and 12.46) buffers, or a custom user-centered set ofbuffers, or both.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unles
12、s otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently h
13、igh purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean distilled water or water of1This test method is under the jurisdiction of ASTM Committee D15 on EngineCoolants and is the dire
14、ct responsibility of Subcommittee D15.04 on ChemicalProperties.Current edition approved Nov. 1, 2009. Published December 2009. Originallyapproved in 1953 as D1287 53 T. Last previous edition approved in 2002 asD1287 91(02). DOI: 10.1520/D1287-09.2For referenced ASTM standards, visit the ASTM website
15、, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications , AmericanChemical Society, Washington, DC. For sugges
16、tions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.1Copyright ASTM International,
17、100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.equal purity. Distilled water shall be boiled thoroughly, orpurged with carbon dioxide-free air, to remove carbon dioxideand shall be protected with a soda-lime tube or its equivalentwhile cooling and in storage. The
18、 pH of the water shall bebetween 6.2 and 7.2 at 25C.6.3 Standard Buffer SolutionsThe buffer solutions forcalibrating the pH meter and electrode pair shall be preparedfrom salts sold specifically for use, either singly or in combi-nation, as pH standards. The salts shall be dried for 1 h at110C befor
19、e use, except in the case of borax which shall beused as the decahydrate. The solutions with pH less than 9.5shall be stored in chemically resistant bottles. The alkalinephosphate solution shall be stored in glass bottles coated on theside with paraffin.NOTE 5Commercially available buffer tablets or
20、 prepared buffersolutions may be used.6.4 Standard Buffer Solution pH = 1.68, (Buffer pH 1.68from Fisher Scientific FC Part Number 13620836) orequivalent could be used.6.5 Potassium Hydrogen Phthalate Buffer Solution (0.05M, pH = 4.01 at 25C)Dissolve 10.21 g of potassiumhydrogen phthalate (KHC8H4O4)
21、 in water, and dilute to 1 L.Standard Buffer Solution pH = 4.0, Potassium HydrogenPhthalate (Red, pH 4.01) from Fisher Scientific (FC PartNumber: SB 101500; NISTSRM 185 g) or equivalent couldbe used.6.6 Neutral Phosphate Buffer Solution (0.025 M with re-spect to each phosphate salt, pH = 6.86 at 25C
22、)Dissolve3.40 g of potassium dihydrogen phosphate (KH2PO4) and 3.55g of anhydrous disodium hydrogen phosphate (Na2HPO4)inwater and dilute to 1 L. Standard Buffer Solution pH = 6.86,Potassium Phosphate (pH 6.86 from Fisher Scientific, orNISTSRM 186 le/lle) or equivalent could be used.6.7 Standard Buf
23、fer Solution pH = 7.0, Potassium Phos-phate Monobasic (Yello, pH 7.00) from Fisher Scientific (FCPart Number: SB 107500) or equivalent could be used.6.8 Borax Buffer Solution (0.01 M, pH = 9.18 at 25C)Dissolve 3.81 g of disodium tetraborate decahydrate(Na2B4O710H2O) in water, and dilute to 1 L. Prot
24、ect thissolution from atmospheric carbon dioxide; stopper the bottle atall times except when actually in use. Standard Buffer SolutionpH=9.18, Sodium Tetraborate 3 10 H2O (borax) (pH 9.18)from Fisher Scientific or NISTSRM 187c) or equivalent couldbe used.6.9 Standard Buffer Solution pH=10.00, Potass
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD12872009STANDARDTESTMETHODFORPHOFENGINECOOLANTSANDANTIRUSTS 发动机 冷却剂 防锈剂 PH 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509574.html