ASTM C895-1987(2003) Standard Test Method for Lead and Cadmium Extracted from Glazed Ceramic Tile《从上釉瓷砖提取铅和镉的试验方法》.pdf
《ASTM C895-1987(2003) Standard Test Method for Lead and Cadmium Extracted from Glazed Ceramic Tile《从上釉瓷砖提取铅和镉的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C895-1987(2003) Standard Test Method for Lead and Cadmium Extracted from Glazed Ceramic Tile《从上釉瓷砖提取铅和镉的试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 895 87 (Reapproved 2003)Standard Test Method forLead and Cadmium Extracted from Glazed Ceramic Tile1This standard is issued under the fixed designation C 895; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the precise determination oflead and cadmium extracted by acetic acid from glazed ceramict
3、ile that are intended for use in areas of food preparation. Theprocedure of extraction may be expected to accelerate therelease of lead from the glaze and to serve, therefore, as asevere test that is unlikely to be matched under the actualconditions of usage of such ceramic tile. This test method is
4、specific for lead and cadmium.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the
5、user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 738 Test Method for Lead and Cadmium Extracted fromGlazed Ceramic Surfaces2C 1034 Test Method for Lead and C
6、admium Extracted fromGlazed Ceramic Cookware3C 1035 Specification for Lead and Cadmium Extractedfrom Glazed Ceramic Cookware33. Summary of Test Method3.1 The lead and cadmium extracted from the article undertest, by acetic acid at 20 to 24C (68 to 75F) after 24 h ofleaching, are measured by atomic a
7、bsorption spectrophotom-etry using specific hollow-cathode lamps for lead and cad-mium, respectively.4. Significance and Use4.1 There are several test methods available to measure thelead and cadmium release from dinnerware and cookware (seeTest Methods C 738 and C 1034 and Specification C 1035).The
8、se standards are used as a control to ensure the protectionof the population against a possible health hazard.4Thispotential hazard arises with improperly formulated, applied,fired glazes and decorations. This test method deals specificallywith ceramic tile that are intended to come in contact with
9、foodduring its preparation (for example, counter top tile).5. Interferences5.1 Since specific hollow-cathode lamps for lead and cad-mium are used, there are no interferences.6. Apparatus6.1 Atomic Absorption Spectrophotometer, equipped with a4-in. (102-mm) single slot or Boling burner head and digit
10、alconcentration readout attachment (DCR) if available.5Thisinstrument should have a sensitivity of about 0.5 ppm of leadfor 1 % absorption and a sensitivity of about 0.25 ppm ofcadmium for 1 % absorption. Use the operating conditions asspecified in the instrument manufacturers analytical methodsmanu
11、al.NOTE 11 ppm = 1 mg/L or one part per million is one milligram perlitre.6.2 Hollow-Cathode Lead Lamp, with wavelength set at283.3 or 217.0 nm.6.3 Hollow-Cathode Cadmium Lamp, with wavelength setat 228.8 nm.6.4 Glassware of chemically resistant borosilicate glass tomake reagents and solutions.6.5 T
12、est CellChemically resistant borosilicate glass cylin-der to contain the leaching solution. An open-ended cellapproximately 80 mm in length and 60 mm in internal diameterhas proven suitable.1This test method is under the jurisdiction of ASTM Committee C21 on CeramicWhitewares and Related Products an
13、d is the direct responsibility of SubcommitteeC21.06 on Ceramic Tile.Current edition approved Oct. 1, 2003. Published October 2003. Originallyapproved in 1978. Last previous edition approved in 1998 as C 895 87 (1998).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AS
14、TM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4“Lead Industries, Inc.,” Proceedings, International Conference on CeramicFoodware Safety, 1975, pp. 817.5PerkinElmer Model 303 and
15、JarrellAsh Model 82546 have been foundsuitable for this determination. Other makes of atomic absorption spectrophotom-eters having comparable sensitivity and accuracy and with background correctionare also suitable.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
16、 PA 19428-2959, United States.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Societywhere such specif
17、ications are available.6Other grades may beused provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean distilled
18、 water.7.3 Acetic Acid (4 % by Volume)Mix 1 volume of glacialacetic acid with 24 volumes of water. Run a reagent blank eachtime a 4 % acetic acid solution is prepared.7.4 Detergent RinseAdd 15 g of suitable alkaline deter-gent7to 1 gal (3.79 L) of lukewarm tap water.7.5 Lead Nitrate Solution (1000-p
19、pm Pb)Dissolve 1.598g of lead nitrate (Pb(No3)2) in 4 % acetic acid and dilute to 1L with 4 % acetic acid. Commercially available standard leadsolutions may also be used.7.6 Hydrochloric Acid (1 % by Weight)Mix 1 volume ofconcentrated hydrochloric acid (HCl, sp. gr. 1.19) with 37volumes of water.7.7
20、 Cadmium Solution (1000-ppm Cd)Dissolve 0.9273 gof anhydrous cadmium sulfate in approximately 250 mL of 1 %HCl (see 7.6), and dilute to 500 mL with 1 % HCl. Commer-cially available standard cadmium solutions may also be used.8. Procedure8.1 Preparation of SampleTake, at random, six identicaltiles an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC89519872003STANDARDTESTMETHODFORLEADANDCADMIUMEXTRACTEDFROMGLAZEDCERAMICTILE 上釉 瓷砖 提取 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-508687.html