ASTM C846-1994(2003) Standard Practice for Application of Cellulosic Fiber Insulating Board for Wall Sheathing《樯护蔽用绝热纤维板的应用程序的标准实施规程》.pdf
《ASTM C846-1994(2003) Standard Practice for Application of Cellulosic Fiber Insulating Board for Wall Sheathing《樯护蔽用绝热纤维板的应用程序的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C846-1994(2003) Standard Practice for Application of Cellulosic Fiber Insulating Board for Wall Sheathing《樯护蔽用绝热纤维板的应用程序的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 846 94 (Reapproved 2003)Standard Practice forApplication of Cellulosic Fiber Insulating Board for WallSheathing1This standard is issued under the fixed designation C 846; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the requirements for storing, han-dling, and application of cellulosic fiber insu
3、lating boardproducts.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior t
4、o use.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information only.2. Referenced Documents2.1 ASTM Standards:C 208 Specification for Cellulosic Fiber Insulating Board2D 1554 Terminology Relating to Wood-Base Fiber andPa
5、rticle Panel Materials32.2 Voluntary Product Standard:ANSI/AHA A194.1 Cellulosic Fiberboard42.3 Federal Specifications:FF-N-105-B with Interim Amendment 4 Nails, Brads,Staples and Spikes: Wire Cut and Wrought5UU-B-790-A Building Paper, Vegetable Fiber: (Kraft, Wa-terproofed, Water Repellent and Fire
6、 Resistant)53. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 exterior finishthe shingle, lap, or panel siding ma-terial, masonry veneer, or stucco applied over the sheathing asa protective, decorative exterior finish of the building.3.1.2 fastenersnails, staples, or screws used
7、 for applica-tion of the sheathing.3.1.3 framing membersthose portions of the studs, head-ers, bracing, and blocking which serve to receive the sheathing.Framing members can be wood or metal.3.1.4 regular wall sheathingdescribed in DefinitionsD 1554 and Specification C 208. It is 4 ft (1.22 m) wide
8、withsquare-cut edges on all sides and12 in. (12.7 mm) in thickness.3.1.5 structural wall sheathingdescribed in DefinitionsD 1554 and Specification C 208. When installed in accordancewith Section 7, it is considered a structural sheathing providingadequate racking resistance. It is 4 ft (1.22 m) wide
9、 and12 in.(12.7 mm) or2532 in. (19.8 mm) in thickness with square-cutedges on all sides.3.1.6 vertical applicationsheathing applied with the longedges parallel to the studs.4. Significance and Use4.1 This standard provides recommendations for the instal-lation in a safe and effective manner. Actual
10、conditions mayvary greatly, and additional care should be taken to ensure asafe and effective installation.4.2 This standard presents requirements that are general innature and considered practical. They are not intended asspecific recommendations. The user should consult the manu-facturer for recom
11、mended application methods and procedures.4.3 This standard does not address the applicability ofregulatory limitations. This is the responsibility of the user.5. Materials5.1 Sheathing shall conform to ANSI/AHA A194.1 andSpecification C 208.5.2 Nails for application of sheathing to wood framing sha
12、llconform to Federal Specification FF-N-105-B, including In-terim Amendment 4, and shall be in accordance with Table 1.5.3 Staples for application of12-in. and2532-in. sheathingto wood framing shall meet the following requirements:1This practice is under the jurisdiction of ASTM Committee C16 on The
13、rmalInsulation and is the direct responsibility of Subcommittee C16.22 on Organic andNonhomogeneous Inorganic Thermal Insulations.Current edition approved Oct. 1, 2003. Published October 2003. Originallyapproved in 1976. Last previous edition approved in 1999 as C 846 94 (1999).2Annual Book of ASTM
14、Standards, Vol 04.06.3Annual Book of ASTM Standards, Vol 04.10.4Available from American Hardboard Assoc., 1210 W. Northwest Highway,Palatine, IL.5Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.1Copyright ASTM Internat
15、ional, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Gage 16Thickness, min, in. (mm) 0.057 (1.45)Width, min, in. (mm) 0.063 (1.59)Length, min, in. (mm) 112 (38.1)Crown, min, in. (mm)716 (11.1)Points chisel pointdivergent pointdivergent chisel point5.4 Screws for
16、 application of12-in. and2532-in. sheathingon 14-gage (0.075-in.) (1.90-mm) to 20-gage (0.036-in.)(0.91mm) steel studs shall meet the following requirements:Head type bugle headHead diameter, min, in. (mm)516 (7.94)Length, min, in. (mm) 114 (31.8)Major diameter, in. (mm)964 (3.57)Minor diameter, in.
17、 (mm)764 (2.78)Point drill point5.5 Framing Members shall be of such size and quality asto be structurally adequate for the type of building beingconstructed.5.5.1 Stud spacing shall be 16 in. (0.41 m) or 24 in. (0.61 m)on center depending on code requirements.6. Storage6.1 Sheathing shall be stored
18、 flat, and supported and pro-tected from direct contact with the ground. Sheathing shall notbe stored in a heated warehouse and shall be allowed to cometo equilibrium at job site conditions prior to application.Sheathing should be protected from rain prior to installation.7. Application (see Table 2
19、)7.1 Vertical Application (see Fig. 1)Apply 4-ft (1.22-m)wide by12-in. (12.7-mm) or by2532-in. (19.8-mm) sheathingvertically with long edges parallel to the vertical studs. Centerall joints over the framing members with a18-in. (3.18-mm)gap between edges. Leave a18-in. gap at doors, windows, andhori
20、zontal joints. Sheathing should extend from sill to plate. Ifnot, headers for adequate nailing should be provided at allhorizontal joints. Apply fasteners for12-in. or2532-in. materialusing roofing nails, common nails (5.2) or staples (5.3) forwood framing and screws (5.4) for metal framing. Applyfa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC84619942003STANDARDPRACTICEFORAPPLICATIONOFCELLULOSICFIBERINSULATINGBOARDFORWALLSHEATHING 樯护蔽用 绝热

链接地址:http://www.mydoc123.com/p-508522.html