1、Designation: C76 12aC76 13Standard Specification forReinforced Concrete Culvert, Storm Drain, and Sewer Pipe1This standard is issued under the fixed designation C76; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last
2、revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers reinforced concrete
3、pipe intended to be used for the conveyance of sewage, industrial wastes, andstorm water, and for the construction of culverts.1.2 This specification is the inch-pound companion to Specification C76M; therefore, no SI equivalents are presented in thisspecification. Reinforced concrete pipe that conf
4、orm to the requirements of C76M, are acceptable under this Specification C76unless prohibited by the Owner.NOTE 1This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or therelationship between field load condition and the str
5、ength classification of pipe. However, experience has shown that the successful performance of thisproduct depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that installation conforms to the constructionspecifications. The owner of the reinforced concrete
6、 pipe specified herein is cautioned that he must correlate the field requirements with the class of pipespecified and provide inspection at the construction site.NOTE 2Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (Specification C655).2.
7、 Referenced Documents2.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelA615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concrete ReinforcementA706/A706M Specification for Low-Alloy Steel Deformed and Plain Bars for Concrete ReinforcementA1064/A1064M Specifica
8、tion for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for ConcreteC33 Specification for Concrete AggregatesC76M Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Metric)C150 Specification for Portland CementC260 Specification for Air-Entraining Admix
9、tures for ConcreteC309 Specification for Liquid Membrane-Forming Compounds for Curing ConcreteC494/C494M Specification for Chemical Admixtures for ConcreteC497 Test Methods for Concrete Pipe, Manhole Sections, or TileC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash
10、 and Raw or Calcined Natural Pozzolan for Use in ConcreteC655 Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer PipeC822 Terminology Relating to Concrete Pipe and Related ProductsC989 Specification for Slag Cement for Use in Concrete and MortarsC1017/C1017M Specification f
11、or Chemical Admixtures for Use in Producing Flowing ConcreteC1116 Specification for Fiber-Reinforced Concrete and Shotcrete3. Terminology3.1 DefinitionsFor definitions of terms relating to concrete pipe, see Terminology C822.1 This specification is under the jurisdiction of ASTM Committee C13 on Con
12、crete Pipe and is the direct responsibility of Subcommittee C13.02 on Reinforced Sewerand Culvert Pipe.Current edition approved Sept. 15, 2012Jan. 15, 2013. Published October 2012February 2013. Originally approved in 1930. Last previous edition approved in 2012 asC76 12.C76 12A. DOI: 10.1520/C0076-1
13、2A.10.1520/C0076-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and
14、 is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only t
15、he current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Classification4.1 Pipe manufactured in accordance with this specification shall be of
16、five classes identified as Class I, Class II, Class III, ClassIV, and Class V. The corresponding strength requirements are prescribed in Tables 1-5.5. Basis of Acceptance5.1 Unless otherwise designated by the owner at the time of, or before placing an order, there are two separate and alternativebas
17、es of acceptance. Independent of the method of acceptance, the pipe shall be designed to meet both the 0.01-in. crack andultimate strength requirements specified in Tables 1-5.5.1.1 Acceptance on the Basis of Plant Load-Bearing Tests, Material Tests, and Inspection of Manufactured Pipe for VisualDef
18、ects and ImperfectionsAcceptability of the pipe in all diameters and classes produced in accordance with 7.1 or 7.2 shall bedetermined by the results of the three-edge bearing tests as defined in 11.3.1; by such material tests as are required in 6.2, 6.3, 6.5,and 6.6; by an absorption test of the co
19、ncrete from the wall of the pipe as required in 11.9; and by visual inspection of the finishedpipe to determine its conformance with the accepted design and its freedom from defects.5.1.2 Acceptance on the Basis of Material Tests and Inspection of Manufactured Pipe for Defects and ImperfectionsAccep
20、tability of the pipe in all diameters and classes produced in accordance with 7.1 or 7.2 shall be determined by the resultsof such material tests as are required in 6.2, 6.3, 6.5, and 6.6; by crushing tests on concrete cores or cured concrete cylinders; byan absorption test of the concrete from the
21、wall of the pipe for each mix design that is used on an order; and by inspection of thefinished pipe including amount and placement of reinforcement to determine its conformance with the accepted design and itsfreedom from defects.5.1.3 When agreed upon by the owner and manufacturer, any portion or
22、any combination of the tests itemized in 5.1.1 or 5.1.2may form the basis of acceptance.TABLE 1 Design Requirements for Class I Reinforced Concrete PipeANOTE 1See Section 5 for basis of acceptance specified by the owner.The strength test requirements in pounds-force per linear foot of pipe under the
23、 three-edge-bearing method shall be either the D-load (test loadexpressed in pounds-force per linear foot per foot of diameter) to produce a 0.01-in. crack, or the D-loads to produce the 0.01-in. crack and the ultimateload as specified below, multiplied by the internal diameter of the pipe in feet.D
24、-load to produce a 0.01-in. crack 800D-load to produce the ultimate load 1200InternalDesignatedDiameter,in.Reinforcement, in.2/linear ft of pipe wallWall A Wall BConcrete Strength, 4000 psi Concrete Strength, 4000 psiWallThickness,in.CircularReinforcementB EllipticalReinforcementCWallThickness,in.Ci
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC762013STANDARDSPECIFICATIONFORREINFORCEDCONCRETECULVERTSTORMDRAINANDSEWERPIPE 钢筋混凝土 涵洞 雨水 污水 标准

链接地址:http://www.mydoc123.com/p-508256.html