《ASTM C667-2017 Standard Specification for Prefabricated Reflective Insulation Systems for Equipment and Pipe Operating at Temperatures above Ambient Air《在高于周围气温条件下设备运行及管子使用预制反射绝热系统.pdf》由会员分享,可在线阅读,更多相关《ASTM C667-2017 Standard Specification for Prefabricated Reflective Insulation Systems for Equipment and Pipe Operating at Temperatures above Ambient Air《在高于周围气温条件下设备运行及管子使用预制反射绝热系统.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C667 09 (Reapproved 2014)C667 17Standard Specification forPrefabricated Reflective Insulation Systems for Equipmentand Pipe Operating at Temperatures above Ambient Air1This standard is issued under the fixed designation C667; the number immediately following the designation indicates th
2、e year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the requirements for all
3、 metal prefabricated, reflective insulation systems for equipment and pipingoperating in air at temperatures above ambient. Typical applications are in nuclear power-generating plants and industrial plants.1.2 Reflective insulation is thermal insulation that reduces radiant heat transfer across spac
4、es by the use of surfaces of highreflectance and low emittance.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.4 This standard do
5、es not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.5 This
6、 international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT
7、) Committee.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC335 Test Method for Steady-State Heat Transfer Properties of Pipe InsulationC411 Test Method for Hot-Surface Performance of High-Temperature Thermal InsulationC835 Test Method for Total Hemispheric
8、al Emittance of Surfaces up to 1400CC854 Test Method for Resistance to External Loads on Metal Reflective Pipe Insulation (Withdrawn 1997)3C1045 Practice for Calculating Thermal Transmission Properties Under Steady-State ConditionsC1058 Practice for Selecting Temperatures for Evaluating and Reportin
9、g Thermal Properties of Thermal InsulationC1061 Test Method for Thermal Transmission Properties of Non-Homogeneous Insulation Panels Installed Vertically(Withdrawn 1995)3C1371 Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers3. Terminology3.1 D
10、efinitions:3.1.1 Terms relating to thermal insulation materials and testing are in accordance with Terminology C168.3.2 Definitions of Terms Specific to This Standard:3.2.1 convection stopsseals used to reduce convection losses.3.2.2 end supportsstructural members placed at the end of a unit of insu
11、lation and fastened to both the inner and outer case.3.2.2.1 Discussion1 This specification is under the jurisdiction of ASTM Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.40 on InsulationSystems.Current edition approved Feb. 1, 2014Oct. 1, 2017. Published
12、March 2014November 2017. Originally approved in 1992. Last previous edition approved in 20092014 asC667C667 09 (2014).-09. DOI: 10.1520/C0667-09R14.10.1520/C0667-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Boo
13、k of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indicati
14、on of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be consi
15、dered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1The primary purpose of the end supports is to increase the structural integrity of the unit.3.2.3 inner casethe innermost sheet of the unit of insulation (clo
16、sest to the hot surface).3.2.3.1 DiscussionThe inner case may perform structural functions in addition to its thermal functions.3.2.4 insulation assemblyan assembly of insulation units arranged and secured together in a prescribed order that comprisesthe complete insulation for a vessel, pump, pipel
17、ine, or other component for a single design objective.3.2.5 insulation systema collection of insulation assemblies, that when secured together in a prescribed order, comprises thecomplete insulation for a vessel, pump, pipeline, or other component for a single design objective.3.2.6 lap strapsstrips
18、 that overlap a longitudinal or circumferential joint in the insulation which aligns adjacent insulationunits and may also serve to restrict air infiltration and convection losses and to shed external falling water.3.2.6.1 DiscussionThe lap straps may be integral with one piece of the outer case or
19、separate strips secured to it.3.2.7 outer casethe outermost sheet or the unit of insulation (farthest from the hot surface). It usually performs structuralfunctions in addition to its thermal functions.3.2.8 penetrationsopenings in a unit of insulation from the cold surface through to the hot surfac
20、e.3.2.9 reflective linersthose reflective sheets or foil interposed between the inner and outer case to reflect radiant energy, tominimize emission of radiant energy, and to restrict internal convection.3.2.10 thickness(see Fig. 1).3.2.11 unit of insulationa single structurally independent assembly
21、of inner case, outer case, reflective liners, and end supports(if required).3.3 Symbols:FIG. 1 Illustration of Terms Relating to Prefabricated Reflective Insulation SystemsC667 1723.3.1 The symbols used in this specification have the following significance:3.3.2 Ccconductance based on the area of in
22、sulation at the cold surface.4. Ordering Information4.1 Ordering information shall include the following:4.1.1 Service requirements including operating hot surface temperature, expected ambient temperatures, and ambient airvelocities,4.1.2 Expected service life and any special environmental exposure
23、s,4.1.3 Permitted average heat loss per unit of cold surface or as otherwise specified,thermal conductance based on hot pipetemperature and insulation cold surface temperature,4.1.4 Personnel exposure surface temperature limitations,4.1.5 Expected seismic, loading, and vibration exposures,4.1.6 Purc
24、hasers systems and equipment drawings,4.1.7 Limits, if any, on size, maximum thickness, weight, or number of insulation units requiring removal for inspection,4.1.8 Location of components or maintenance, or both, and systems requiring removal of units for inspections,4.1.9 Any unusual operating or t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6672017STANDARDSPECIFICATIONFORPREFABRICATEDREFLECTIVEINSULATIONSYSTEMSFOREQUIPMENTANDPIPEOPERATINGATTEMPERATURESABOVEAMBIENTAIR

链接地址:http://www.mydoc123.com/p-507964.html