1、Designation: C654M 11Standard Specification forPorous Concrete Pipe (Metric)1This standard is issued under the fixed designation C654M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthe
2、ses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers porous nonreinforced concretepipe for use in u
3、nderdrains.1.2 This specification is the metric counterpart of Specifi-cation C654.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC150 Specification for Portland CementC497M Test Methods for Concrete Pipe, Manhole Sections,or Tile MetricC595 Specification for Ble
4、nded Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC822 Terminology Relating to Concrete Pipe and RelatedProductsC989 Specification for Slag Cement for Use in Concreteand MortarsC1116 Specification for Fiber-Reinforced Concrete andShotcre
5、te3. Terminology3.1 DefinitionsFor definitions of terms relating to con-crete pipe, see Terminology C822.4. Classification4.1 Pipe manufactured according to this specification shallbe of two classes identified as “Standard-Strength PorousNonreinforced Concrete Pipe” and “Extra-Strength PorousNonrein
6、forced Concrete Pipe.”5. Basis of Acceptance5.1 The acceptability of the pipe shall be determined by theresults of the strength and porosity or rate of infiltration tests,and by inspection to determine whether the pipe conforms tothis specification as to design and freedom from defects.5.2 The pipe
7、shall be acceptable under the strength testswhen they have met the requirements as prescribed in Section10.5.3 Acceptance as to Infiltration PropertiesPipe shall beacceptable under the infiltration test when all test pipe conformto the test requirements as prescribed in Section 10.6. Materials6.1 Co
8、ncreteThe concrete shall consist of cementitiousmaterials, mineral aggregates, and water.6.2 Cementitious Materials:6.2.1 CementCement shall conform to the requirementsfor portland cement of Specification C150 or shall be portlandblast-furnace slag cement, or slag-modified portland cement, orportlan
9、d-pozzolan cement conforming to the requirements ofSpecification C595, except that the pozzolan constituent in theType IP portlandpozzolan cement shall be fly ash.6.2.2 Fly AshFly ash shall conform to the requirements ofSpecification C618, Class F or Class C.6.2.3 Ground Granulated Blast Furnace Sla
10、g (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120of Specification C989.6.2.4 Allowable Combinations of Cementitious MaterialsThe combination of cementitious materials used in the concreteshall be one of the following:6.2.4.1 Portland cement only,6.2.4.2 Portland blast furnace slag
11、 cement only,6.2.4.3 Slag modified portland cement only,6.2.4.4 Portland pozzolan cement only,6.2.4.5 A combination of portland cement and fly ash,6.2.4.6 A combination of portland cement and groundgranulated blast-furnace slag, or6.2.4.7 A combination of portland cement, fly ash (not toexceed 25 %
12、of the total cementitious weight) and groundgranulated blast furnace slag (not to exceed 25 % of the totalcementitious weight).1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.01 onNon-Reinforced Concrete Sewer,
13、Drain and Irrigation Pipe.Current edition approved Sept. 1, 2011. Published October 2011. Originallyapproved in 1980. Last previous edition approved in 2005 as C654M 05a. DOI:10.1520/C0654M-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at se
14、rviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.3 AggregatesAggregates shall conform to Specificati
15、onC33 except that the requirement for gradation shall not apply.6.4 Admixtures and BlendsOwner is not prohibited fromobtaining the record of mix design used.6.5 Synthetic FibersCollated fibrillated virgin polypro-pylene fibers are not prohibited in concrete pipe as a nonstruc-tural manufacturing mat
16、erial. Only Type III synthetic fibersdesigned and manufactured specifically for use in concrete andconforming to the requirements of Specification C1116 shall beaccepted.7. Design7.1 Design TablesDesign requirements shall be in accor-dance with Table 1 and Table 2 and Fig. 1. Wall thickness usedshal
17、l be not less than the value shown, except as affected by thetolerance herein specified.8. Joints8.1 The joints shall be of such design and the ends of theconcrete pipe sections so formed that the pipe can be laidtogether to make a continuous line of pipe compatible with thepermissible variations gi
18、ven in Section 7.9. Manufacture9.1 MixtureThe aggregates shall be sized, graded, propor-tioned, and mixed with such proportions of cementitiousmaterials and water as will produce a homogeneous concretemixture of such quality that the pipe will conform to the testand design requirements of this speci
19、fication.9.2 CuringPipe shall be subjected to any one of themethods of curing described in 9.2.1 through 9.2.3,ortoanyother method or combination of methods approved by theowner that will give satisfactory results. The pipe shall becured for a sufficient length of time so that the concrete willdevel
20、op the specified strength requirement at 28 days or less.9.2.1 Steam CuringPipe shall be placed in a curingchamber, free from outside drafts, and cured in a moistatmosphere maintained by the injection of steam for such timeand at such temperature as needed to enable the pipe to meetthe strength requ
21、irements. The curing chamber shall be con-structed as to allow full circulation of steam around the entirepipe.9.2.2 Water CuringConcrete pipe shall be water-cured bycovering with water-saturated material or by a system ofperforated pipes, mechanical sprinklers, porous hose, or by anyother approved
22、method that will keep the pipe moist during thespecified curing period.9.2.3 The manufacturer has the option to combine themethods described in 9.2.1 and 9.2.2 provided the specifiedstrength is attained.9.3 Specials:9.3.1 General RequirementsSpecial shapes or fittingssuch as wyes, tees, bends, and a
23、dapters for use with concretepipe conforming to this specification shall be made of porousor nonporous concrete in such manner as will provide strengthat least equal to the class of the adjacent pipe to which they arejoined; and shall conform to all other requirements specifiedfor pipe of correspond
24、ing class and internal diameter, exceptminimum infiltration. Joints shall be the same type as used inthe adjoining pipe.9.3.2 Wyes and TeesFabricated branches for wyes andtees shall be securely attached to the wall of the pipe and shallbe flush with the inside surface of the pipe.10. Physical Requir
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC654M2011STANDARDSPECIFICATIONFORPOROUSCONCRETEPIPEMETRIC 多孔 混凝土 米制 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-507907.html