ASTM C547-2007e1 Standard Specification for Mineral Fiber Pipe Insulation《矿物纤维管绝缘的标准规范》.pdf
《ASTM C547-2007e1 Standard Specification for Mineral Fiber Pipe Insulation《矿物纤维管绝缘的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C547-2007e1 Standard Specification for Mineral Fiber Pipe Insulation《矿物纤维管绝缘的标准规范》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 547 07e1Standard Specification forMineral Fiber Pipe Insulation1This standard is issued under the fixed designation C 547; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parent
2、heses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.e1NOTESection 2 and 11.1.5.3 were editorially corrected in May 2008.1. Scope1.1 T
3、his specification covers mineral fiber insulation pro-duced to form hollow cylinders for standard pipe and tubingsizes. The mineral fiber pipe insulation may be molded orprecision v-grooved, with one or more walls split longitudi-nally for use on pipe temperatures up to 1400F (760C).1.2 For satisfac
4、tory performance, properly installed protec-tive vapor retarders or barriers should be used on sub-ambienttemperature applications to reduce movement of moisturethrough or around the insulation to the colder surface. Failureto use a vapor barrier can lead to insulation and systemdamage. Refer to Pra
5、ctice C 921 to aid material selection.1.3 Flexible mineral fiber wrap products such asperpendicular-oriented fiber insulation rolls, non-precision ormanually scored block or board, or flexible boards or blanketsused as pipe insulation, are not covered by this specification.1.4 The values stated in i
6、nch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.5 For Naval Sea Systems Command (NAVSEA) accep-tance, materials must also comply with Supplemental Require-ments. See Annex A1 of this standard.1.6 The following safety hazards caveat applies
7、 to the testmethods portion, Section 11, only: This standard does notpurport to address all of the safety concerns, if any, associatedwith its use. It is the responsibility of the user of this standardto establish appropriate safety and health practices anddetermine the applicability of regulatory l
8、imitations prior touse.2. Referenced Documents2.1 ASTM Standards:2C 167 Test Methods for Thickness and Density of Blanketor Batt Thermal InsulationsC 168 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means
9、ofthe Guarded-Hot-Plate ApparatusC 302 Test Method for Density and Dimensions of Pre-formed Pipe-Covering-Type Thermal InsulationC 335 Test Method for Steady-State Heat Transfer Proper-ties of Pipe InsulationC 356 Test Method for Linear Shrinkage of PreformedHigh-Temperature Thermal Insulation Subje
10、cted to Soak-ing HeatC 390 Practice for Sampling and Acceptance of ThermalInsulation LotsC411 Test Method for Hot-Surface Performance of High-Temperature Thermal InsulationC 447 Practice for Estimating the Maximum Use Tempera-ture of Thermal InsulationsC 585 Practice for Inner and Outer Diameters of
11、 RigidThermal Insulation for Nominal Sizes of Pipe and Tubing(NPS System)C 612 Specification for Mineral Fiber Block and BoardThermal InsulationC 795 Specification for Thermal Insulation for Use in Con-tact with Austenitic Stainless SteelC 921 Practice for Determining the Properties of JacketingMate
12、rials for Thermal InsulationC 1045 Practice for Calculating Thermal TransmissionProperties Under Steady-State ConditionsC 1058 Practice for Selecting Temperatures for Evaluatingand Reporting Thermal Properties of Thermal InsulationC 1104/C 1104M Test Method for Determining the WaterVapor Sorption of
13、 Unfaced Mineral Fiber InsulationE84 Test Method for Surface Burning Characteristics ofBuilding Materials2.2 Other Standards:UL 723 Tests for Surface Burning of Building Materials31This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibilit
14、y of Subcommittee C16.20 onHomogeneous Inorganic Thermal Insulations.Current edition approved Aug. 1, 2007. Published September 2007. Originallyapproved in 1964. Last previous edition approved in 2006 as C 547 06.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cu
15、stomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Underwriters Laboratories (UL), 333 Pfingsten Rd., North-brook, IL 60062-2096, http:/.1Copyright ASTM International, 100 Barr Harbor
16、 Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.NFPA 255 Method of Tests of Surface Burning Character-istics of Building Materials4CAN/ULC-S102 Standard Method of Test for SurfaceBurning Characteristics of Building Materials and Assem-blies53. Terminology3.1 The definitions in T
17、erminology C 168 shall apply to theterms used in this specification.3.2 Definitions of Terms Specific to This Standard:3.2.1 moldedrefers to products preformed via a moldingprocess to yield full-round cylindrical pipe insulation sections.3.2.2 precision v-grooverefers to products fabricated frommach
18、ined board via a precision cutting process. Machinedsegments are adhered to a backing to form a full-roundcylindrical pipe insulation section. Due to the precision of theprocess, the product has no gaps when installed.4. Classification4.1 Products covered by this specification are classifiedaccordin
19、g to maximum use temperature as follows:4.1.1 Type IMolded, for use to 850F (454C).Grade ARequires no heat-up scheduleGrade BHeat-up schedule is required4.1.2 Type IIMolded, for use to 1200F (650C).Grade ARequires no heat-up scheduleGrade BHeat-up schedule is required4.1.3 Type IIIPrecision v-groove
20、, for use to 1200F(650C).Grade ARequires no heat-up scheduleGrade BHeat-up schedule is required4.1.4 Type IVMolded, for use to 1000F (538C).Grade ARequires no heat-up scheduleGrade BHeat-up schedule is required4.1.5 Type VMolded, for use to 1400F (760C)Grade ARequires no heat-up scheduleGrade BHeat-
21、up schedule is requiredNOTE 1Warning: Grade B may not be suitable for applicationsrequiring hot installation capability at the maximum temperature indi-cated. Products having a Grade B designation are designed to be used witha heat-up schedule. Failure to use a heat-up schedule with Grade Bproducts
22、may lead to an exothermic reaction. This is dependent onthickness and temperature. Consult the manufacturer or manufacturersliterature for special heat rate considerations.4.2 Binder decomposition at elevated temperature may be alimiting factor in certain applications. Consult the manufac-turer rega
23、rding special heat rate considerations.5. Materials and Manufacturer5.1 Composition The mineral fiber insulation for pipesshall be manufactured from mineral substance such as rock,slag, or glass, processed from a molten state into fibrous formwith binder. Asbestos shall not be used as an ingredient
24、orcomponent part. Some products may also contain adhesive.5.2 Jackets (Facings)The user of this specification has theoption to specify that the insulation be jacketed.NOTE 2The user is advised that the maximum use temperature offactory-applied facings and adhesives may be lower than the maximumuse t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC5472007E1STANDARDSPECIFICATIONFORMINERALFIBERPIPEINSULATION 矿物纤维 绝缘 标准规范 PDF

链接地址:http://www.mydoc123.com/p-466973.html