ASTM C457 C457M-2011 Standard Test Method for Microscopical Determination of Parameters of the Air-Void System in Hardened Concrete《硬化混凝土孔隙系统参数显微测定的标准试验方法》.pdf
《ASTM C457 C457M-2011 Standard Test Method for Microscopical Determination of Parameters of the Air-Void System in Hardened Concrete《硬化混凝土孔隙系统参数显微测定的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C457 C457M-2011 Standard Test Method for Microscopical Determination of Parameters of the Air-Void System in Hardened Concrete《硬化混凝土孔隙系统参数显微测定的标准试验方法》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C457/C457M 11Standard Test Method forMicroscopical Determination of Parameters of the Air-VoidSystem in Hardened Concrete1This standard is issued under the fixed designation C457/C457M; the number immediately following the designation indicates the yearof original adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method describes procedures for microscopicaldeterminations of the air content
3、of hardened concrete and ofthe specific surface, void frequency, spacing factor, and paste-air ratio of the air-void system in hardened concrete (1).2Twoprocedures are described:1.1.1 Procedure A, the linear-traverse method (2, 3).1.1.2 Procedure B, the modified point-count method (3, 4, 5,6).1.2 Th
4、is test method is based on prescribed procedures thatare applied to sawed and lapped sections of specimens ofconcrete from the field or laboratory.1.3 It is intended to outline the principles of this test methodand to establish standards for its adequate performance but notto describe in detail all
5、the possible variations that might beused to accomplish the objectives of this test method.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independ
6、ently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.5 This standard does not purport to address all of thesafety concerns associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth prac
7、tices and determine the applicability of regulatorylimitations prior to use. For specific hazard statements see 8.3and 10.1.2. Referenced Documents2.1 ASTM Standards:3C42/C42M Test Method for Obtaining and Testing DrilledCores and Sawed Beams of ConcreteC125 Terminology Relating to Concrete and Conc
8、rete Ag-gregatesC138/C138M Test Method for Density (Unit Weight),Yield, and Air Content (Gravimetric) of ConcreteC173/C173M Test Method for Air Content of FreshlyMixed Concrete by the Volumetric MethodC231 Test Method for Air Content of Freshly Mixed Con-crete by the Pressure MethodC666/C666M Test M
9、ethod for Resistance of Concrete toRapid Freezing and ThawingC670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsC672/C672M Test Method for Scaling Resistance of Con-crete Surfaces Exposed to Deicing ChemicalsC823 Practice for Examination and Sampling
10、of HardenedConcrete in ConstructionsC856 Practice for Petrographic Examination of HardenedConcreteD92 Test Method for Flash and Fire Points by ClevelandOpen Cup Tester2.2 American Concrete Institute Standards:201.2R Guide to Durable Concrete4211.1 Recommended Practice for Selecting Proportions forNo
11、rmal, Heavyweight, and Mass Concrete43. Terminology3.1 For definitions of terms used in this test method, refer toTerminology C125.3.2 Definitions of Terms Specific to This Standard:3.2.1 average chord length ( l ), nthe average length ofthe chords formed by the transection of the voids by the line
12、oftraverse; the unit is a length.3.2.2 paste-air ratio (p/A), nthe ratio of the volume ofhardened cement paste to the volume of the air voids in theconcrete.3.2.3 paste content (p), nthe proportion of the totalvolume of the concrete that is hardened cement paste expressedas percentage by volume.1Thi
13、s test method is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.65 on Petrography.Current edition approved Oct. 1, 2011. Published November 2011. Originallyapproved in 1960. Last previous edition approved in 2010 as
14、 C457/C457M10a.DOI: 10.1520/C0457_C0457M-11.2The boldface numbers in parentheses refer to the list of references at the end ofthis test method.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards vo
15、lume information, refer to the standards Document Summary page onthe ASTM website.4Available fromAmerican Concrete Institute (ACI), P.O. Box 9094, FarmingtonHills, MI 48333-9094, http:/www.aci-int.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 10
16、0 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.3.1 DiscussionWhen this parameter is calculated, it isthe sum of the proportional volumes of the cement, the netmixing water (including the liquid portions of any chemicaladmixtures), and any supplementary cementit
17、ious materialspresent (7, 8).3.2.4 spacing factor ( L ), na parameter related to themaximum distance in the cement paste from the periphery ofan air void, the unit is a length.3.2.5 specific surface (a), nthe surface area of the airvoids divided by their volume, expressed in compatible unitsso that
18、the unit of specific surface is a reciprocal length.3.2.6 void frequency (n), nvoids per unit length of tra-verse; the number of air voids intercepted by a traverse linedivided by the length of that line; the unit is a reciprocal length.3.2.6.1 DiscussionThe value for void frequency (n) can-not be d
19、irectly determined by the paste-air ratio method as thisvalue refers to the voids per unit measure of traverse in the totalconcrete (including aggregate).3.2.7 water void, na space enclosed by the cement pastethat was occupied by water at the time of setting and frequentlyfound under an aggregate pa
20、rticle or reinforcing bar. A water-void is usually identified by its irregular shape or evidence thata channel or cavity has been created by bleed water trapped inthe concrete at the time it hardened.4. Summary of Test Method4.1 Procedure A, Linear-Traverse MethodThis procedureconsists of the determ
21、ination of the volumetric composition ofthe concrete by summing the distances traversed across a givencomponent along a series of regularly spaced lines in one ormore planes intersecting the sample. The data gathered are thetotal length traversed (Tt), the length traversed through airvoids (Ta), the
22、 length traversed through paste (Tp), and thenumber of air voids intersected by the traverse line (N). Thesedata are used to calculate the air content and various param-eters of the air-void system. If only the air content is desired,only Taand Ttneed be determined.4.2 Procedure B, Modified Point-Co
23、unt MethodThis pro-cedure consists of the determination of the volumetric compo-sition of the concrete by observation of the frequency withwhich areas of a given component coincide with a regular gridsystem of points at which stops are made to enable thedeterminations of composition. These points ma
24、y be in one ormore planes intersecting the sample. The data gathered are thelinear distance between stops along the traverse (I), the totalnumber of stops (St), the number of stops in air voids (Sa), thenumber of stops in paste (Sp), and the number of air voids (N)intersected by the line of traverse
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC457C457M2011STANDARDTESTMETHODFORMICROSCOPICALDETERMINATIONOFPARAMETERSOFTHEAIRVOIDSYSTEMINHARDENEDCONCRETE

链接地址:http://www.mydoc123.com/p-466626.html