1、Designation: C240 08 (Reapproved 2012)Standard Test Methods ofTesting Cellular Glass Insulation Block1This standard is issued under the fixed designation C240; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the testing of cellular glassinsulation block for density, water absorption, compressivestrength, flexur
3、al strength at ambient temperature; preparationfor chemical analysis; and thermal conductivity measurements.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are n
4、ot considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior
5、 to use.2. Referenced Documents2.1 ASTM Standards:2C165 Test Method for Measuring Compressive Properties ofThermal InsulationsC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate
6、ApparatusC203 Test Methods for Breaking Load and Flexural Proper-ties of Block-Type Thermal InsulationC303 Test Method for Dimensions and Density of Pre-formed Block and BoardType Thermal InsulationC390 Practice for Sampling and Acceptance of ThermalInsulation LotsC518 Test Method for Steady-State T
7、hermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC871 Test Methods for Chemical Analysis of Thermal Insu-lation Materials for Leachable Chloride, Fluoride, Silicate,and Sodium IonsC226 Specification for Air-Entraining Additions for Use inthe Manufacture of Air-Entraining Hydrau
8、lic Cement2.2 ISO Standard:ISO 3951 Sampling Procedure and Charts for Inspection byVariables for Percent Nonconforming32.3 Military Standard:MIL-I-24244 Specification Insulation Materials with SpecialCorrosion, Chloride, and Fluoride Requirements42.4 Other Standard:NRC 1.36 Nonmetallic Thermal Insul
9、ation for AusteniticStainless Steel53. Terminology3.1 DefinitionsTerminology C168 shall be considered asapplying to the terms considered in these test methods.4. Significance and Use4.1 From a general standpoint, these test methods outlinethe particular points which have to be taken into account whe
10、napplying ASTM standard test methods to the case of cellularglass insulating block.5. Test Methods5.1 General Sample PreparationAll tests have to be runon dry specimens. In case of need, the sample must beunpacked and stored in a dry place in such a way that allsurfaces are exposed to the ambient ai
11、r for a minimum of 24hours before testing.5.2 DensityDetermine the density in accordance with TestMethod C303. Preferably, the density shall be measured on afull block, 18 by 24 in. (450 by 600 mm) by full thickness.5.2.1 It shall be noted that density is interesting as such forcalculation of insula
12、ted equipment load and because it hasinfluence on the other important properties of cellular glass.But it shall not be considered in itself as a criterion foracceptance in the case of cellular glass.5.3 Water Absorption:1These test methods are under the jurisdiction of ASTM Committee C16 onThermal I
13、nsulation and are the direct responsibility of Subcommittee C16.32 onMechanical Properties.Current edition approved Sept. 1, 2012. Published November 2012. Originallyapproved in 1950. Last previous edition approved in 2008 as C240 081. DOI:10.1520/C0240-08R12.2For referenced ASTM standards, visit th
14、e ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY
15、10036, http:/www.ansi.org.4Available from Standardization Documents Order Desk, Bldg. 4, Section D,700 Robbins Ave., Philadelphia, PA 19111-5094.5Available from Director of Regulatory Standards, US Atomic EnergyCommission, Washington, DC 20545.Copyright ASTM International, 100 Barr Harbor Drive, PO
16、Box C700, West Conshohocken, PA 19428-2959. United States15.3.1 ScopeThis test method covers the determination ofwater absorption of cellular glass insulating blocks by measur-ing the amount of water retained as a result of completeimmersion for a prescribed time interval. Surface blotting isused to
17、 correct for the water absorbed on the cut surface cells.5.3.2 Significance and UseThis test method provides ameans of measuring the water absorption of cellular glassinsulating blocks under isothermal conditions as a result ofdirect immersion in liquid water. It is intended for use inproduct evalua
18、tion and quality control.5.3.3 Equipment and Materials:5.3.3.1 Balance, minimum 1500 g capacity and 0.1 g orgreater sensitivity.5.3.3.2 Immersion Tank, equipped with inert specimen sup-ports and top surface weights such as stainless steel.5.3.3.3 Synthetic Sponge, 4 by 7 by 1.5 in. (100 by 180 by40
19、mm) or larger. Sponges found acceptable to use includecellulosic sponges and fine-pored absorbent synthetic plasticsponges.5.3.3.4 Test Room, with temperature of 70 6 5F (21 63C) and relative humidity of 50 6 10 %.5.3.3.5 Distilled Water.5.3.4 Procedure:5.3.4.1 Carefully measure the thickness, width
20、, and lengthto the nearest 1 mm of a cellular glass block, preferably 2 by12 by 18 in. (50 by 300 by 450 mm) and calculate the volumeand exposed surface area.5.3.4.2 Weigh the specimen to the nearest 0.1 g (W1), thensubmerge it horizontally under 25 mm (1 in.) of watermaintained at 70 6 5F (21 6 3C)
21、. Inert top surface weightsare required to keep it submerged. After submerging it for 2 h,set the specimen on end on a damp cotton bath towel to drainfor 10 min. After the 10 min, remove the excess surface waterby hand with a damp sponge for 1 min per large face and 1 minfor the four sides. Wring ou
22、t the sponge before and once inbetween for each face and pass a minimum of two times oneach surface. Blot each face of the specimen equally bycompressing the sponge by a minimum of 10 % of its thick-ness. Weigh the specimen immediately (W2) to the nearest 0.1g.5.3.5 Calculation of ResultsCalculate t
23、he weight of waterabsorbed (W2 W1) and express it as a function of the exteriorsurface of the sample (g/cm2). Water absorption is also beexpressed as a function of volume percent, absorbed watervolume divided by specimen volume; or as a function ofweight percent, weight of water absorbed (W2 W1) div
24、idedby the dry specimen weight (W1). Such ways of expressing theresults shall be strictly limited to direct comparison of resultson specimens of identical sizes.5.3.6 Precision and BiasThe precision as determined ininter-laboratory tests is given in Research Report RR C16-1007.6The repeatability or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC24020082012STANDARDTESTMETHODSOFTESTINGCELLULARGLASSINSULATIONBLOCK 泡沫 玻璃 绝缘 测试 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-466111.html