ASTM C1764-2012 Standard Test Methods for Non Metallic Plaster Bases (Lath) Used with Portland Cement Based Plaster in Vertical Wall Applications《直墙应用件中使用带波特兰水泥基塑料的非金属塑料基(板条)标准试验方法.pdf
《ASTM C1764-2012 Standard Test Methods for Non Metallic Plaster Bases (Lath) Used with Portland Cement Based Plaster in Vertical Wall Applications《直墙应用件中使用带波特兰水泥基塑料的非金属塑料基(板条)标准试验方法.pdf》由会员分享,可在线阅读,更多相关《ASTM C1764-2012 Standard Test Methods for Non Metallic Plaster Bases (Lath) Used with Portland Cement Based Plaster in Vertical Wall Applications《直墙应用件中使用带波特兰水泥基塑料的非金属塑料基(板条)标准试验方法.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1764 12Standard Test Methods forNon Metallic Plaster Bases (Lath) Used with PortlandCement Based Plaster in Vertical Wall Applications1This standard is issued under the fixed designation C1764; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods evaluate the performance of verticalwall applications of non m
3、etallic plaster bases used withPortland Cement Based Plaster under a variety of test expo-sures.1.2 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. Thevalues stated in each system may not be exact equivalents;therefore, each system shall be us
4、ed independently of the other.Combining values from the two systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate
5、 safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C926 Specification for Application of Portland Cement-Based PlasterE330 Test Method for Structural Performance of ExteriorWindows, Doors, Skylights and Curt
6、ain Walls by UniformStatic Air Pressure DifferenceE631 Terminology of Building ConstructionsE2098 Test Method for Determining Tensile BreakingStrength of Glass Fiber Reinforcing Mesh for Use in ClassPB Exterior Insulation and Finish Systems (EIFS), afterExposure to a Sodium Hydroxide Solution2.2 ICC
7、-ES Acceptance Criteria:AC 191 Acceptance Criteria for Metal Plaster Bases (Lath)3. Terminology3.1 DefinitionsFor definitions of terms used in these testmethods, refer to Terminology E631.3.2 Definitions of Terms Specific to This Standard:3.2.1 non metallic, plaster base (lath)material used as abase
8、 for Portland Cement Based Plaster that is flat or selffurred.4. Significance and Use4.1 General:4.1.1 Non metallic reinforced Portland Cement Based Plas-ter are vertically applied exterior wall claddings that may besubject to variety of conditions over the claddings service life.The series of tests
9、 described in this standard evaluates perfor-mance under a variety of test conditions and exposures. Anygiven project may not be subject to all of the test conditionsdescribed herein and all of the test methods may not evaluateall exposures for a given project.4.2 Transverse Load:4.2.1 This test det
10、ermines the ultimate wind load resistanceof the wall assembly including influence of the framing,sheathing, and means of attachment.4.3 Vertical Load:4.3.1 The weight and attachment mechanism of PortlandCement Based Plaster results in a vertical load transfer to theplaster base. This test method det
11、ermines the ultimate verticalload capacity of the cladding assembly based on taking thespecimen to failure.4.4 Embedment:4.4.1 Plaster bases serve as a key, reinforcement and attach-ment mechanism for Portland Cement Based Plaster. Thethickness, profile, and material properties of the plaster basesm
12、ust be such that it is adequately embedded in the PortlandCement Based Plaster. This can be accomplished through useof a self furred non metallic plaster base or other means suchas furring strips. This test procedure determines the effective-ness of the furring mechanism to ensure that the minimumem
13、bedment is obtained.4.5 Fastener Pull Through Resistance:1These test methods are under the jurisdiction of ASTM Committee C11 onGypsum and Related Building Materials and Systems and is the direct responsibilityof Subcommittee C11.02 on Specifications and Test Methods for Accessories andRelated Produ
14、cts.Current edition approved Oct. 1, 2012. Published August 2013. DOI: 10.1520/C1764-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summa
15、ry page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.5.1 The non metallic lath is secured to the building frameor substrate with fasteners. This test evaluates the fastenerattachment effectiveness.4.6 Alkali Re
16、sistance (Glass Fiber Lath Only):4.6.1 Per E2098.5. Sampling, Test Specimens, and Test Units5.1 The number, size and configuration of the test speci-mens shall be as per each test procedure with the exception ofTransverse Load tests which shall incorporate wood or steelframing as determined by the u
17、ser. Samples shall be represen-tative of standard products and construction methods.6. Test Specimens6.1 Transverse Load:6.1.1 Construct three test specimens. Test specimen sizeshall be minimum 4 ft (1.2 m) by 8 ft (2.4 m) and constructedrepresentative of end use conditions. Framing members shallbe
18、wood or steel as determined by the user. C926 PortlandCement Based Plaster shall be mixed and applied in theconfiguration of the test specimen.6.2 Vertical Load:6.2.1 Construct three test frames measuring 12 inch (305mm) by 20 inch (508 mm) using nominal 2 inch (50 mm) by4 inch (100 mm) wood lumber
19、with specific gravity of 0.42.The test frame shall have one intermediate stud with top andbottom plates and sheathed one side with12 inch (13 mm) thickgypsum sheathing. Attach studs to plates using 2 16d (312 inch(89 mm) length) nails and sheathing to framing using 6d (2inch length) common nails or
20、equal fastened 8 inches (200mm) on center. A test panel shall be prepared measuring 6inches (152 mm) high by 16 inches (406 mm) wide andconsisting of a water-resistive barrier (provided to preventadhesion of the test panel to the test frame); non metallicplaster base, which is attached through the w
21、ater-resistivebarrier to the intermediate framing member with one fastener;and apply Portland Cement Based Plaster per C926. Thesamples shall be cured a minimum of 28 days. Refer to Fig. 1FIG. 1 Test AssemblyC1764 122for an illustration of the test assembly.6.3 Embedment:6.3.1 Construct one test fra
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17642012STANDARDTESTMETHODSFORNONMETALLICPLASTERBASESLATHUSEDWITHPORTLANDCEMENTBASEDPLASTERINVERTICALWALLAPPLICATIONS

链接地址:http://www.mydoc123.com/p-465764.html