《ASTM C1374-2018 Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation.pdf》由会员分享,可在线阅读,更多相关《ASTM C1374-2018 Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1374 14C1374 18Standard Test Method forDetermination of Installed Thickness of PneumaticallyApplied Loose-Fill Building Insulation1This standard is issued under the fixed designation C1374; the number immediately following the designation indicates the year oforiginal adoption or, in t
2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers determination of the installed thickness of pneumatically app
3、lied loose-fill building insulations priorto settling by simulating an open attic with horizontal blown applications.1.2 This test method is a laboratory procedure for use by manufacturers of loose-fill insulation for product design, labeldevelopment, and quality control testing. The apparatus used
4、produces installed thickness results at a given mass/unit area.1.3 This test method is not the same as the design density procedures described in Test Methods C520 or Specifications C739or C764.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses
5、are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safe
6、ty safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Develo
7、pment of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC520 Test Methods for Density of Granular Loose Fill InsulationsC73
8、9 Specification for Cellulosic Fiber Loose-Fill Thermal InsulationC764 Specification for Mineral Fiber Loose-Fill Thermal InsulationE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method3. Terminology3.1 DefinitionsUnless otherwise stated, the definitions l
9、isted in Terminology C168 are applicable herein.3.2 Definitions of Terms Specific to This Standard:3.2.1 installed thickness, nthe average thickness, as measured immediately after application of blown insulation materialwhen applied at a given mass/unit area.4. Summary of Test Method4.1 Astandardize
10、d test chamber of 80 ft2 (7.4 m2) is used as a receptacle to receive a calculated mass/unit area of pneumaticallyapplied insulation.4.2 The mass of insulation to be blown into the test chamber is calculated from the bag label information.1 This test method is under the jurisdiction of ASTM Committee
11、 C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.32 on MechanicalProperties.Current edition approved April 15, 2014Sept. 1, 2018. Published May 2014September 2018. Originally approved in 1997. Last previous edition approved in 20092014as C137403(2009).C1374 14. DOI: 10
12、.1520/C1374-14. 10.1520/C1374-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM
13、 standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all
14、 cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3 The mass of insulation prescribed in 4.2 is uniformly blown into the tes
15、t chamber.4.4 The thickness of the blown insulation is determined at 13 predetermined locations.4.5 The thickness average of three tests is the installed thickness for the mass/unit area being tested.5. Significance and Use5.1 This test method was designed to give the manufacturer of loose-fill insu
16、lation products a way of determining what theinitial installed thickness should be in a horizontal open attic for pneumatic applications.5.2 The installed thickness value developed by this test method is intended to provide guidance to the installer in order toachieve a minimum mass/unit area for a
17、given R-value.5.3 For the purpose of product design, testing should be done at a variety of R-values. At least three R-values should be used:the lowest R-value on the product label, the highest R-value on the product label, and an R-value near the midpoint of the R-valuerange.NOTE 1For quality contr
18、ol purposes, testing may be done at one R-value of R-19 (hft2F/Btu) or higher.5.4 Specimens are blown in a manner consistent with the intended installation procedure. Blowing machine settings should berepresentative of those typically used for field application with that machine.5.5 The material blo
19、wn for a given R-value as part of the installed thickness test equals the installed mass/unit area times thetest chamber area. This mass can be calculated from information provided on the package label at the R-value prescribed.6. Apparatus6.1 Blowing MachineA pneumatic blowing machine, designed pri
20、marily for handling loose-fill insulation materials, shall beused for blowing the insulation into the test chamber. This machine shall have throughput and material handling characteristicssimilar to that used in field applications.6.2 Blowing HoseThe machine should utilize 150 ft (46 m) of 3in. (76m
21、m) diameter flexible, corrugated blowing hose. Atleast 100 ft (30 m) of the hose should be elevated between 10 and 20 ft (3 and 6 m) above the blowing machine to simulate a typicalinstallation configuration. The hose should have no more than eight 90 bends and no bends may be less than 4ft (1.2m) ra
22、dius.NOTE 2It is good practice to clean the hose periodically by mechanically agitating it with the blower on. This practice should dislodge any piecesof insulation that might be caught in the hose.6.3 Test Specimen ChamberThe specimen chamber shall be constructed in accordance with Fig. 1 with the
23、reference dowelspositioned as shown in Fig. 2.NOTE 3For some insulation materials it may be necessary to use a larger test chamber than shown to accommodate a more representative sample,when the test chamber size is changed, the precision may change.6.4 Weighing DevicesA device is required to weigh
24、the test material before loading into hopper. This device must determinethe test material mass to within 0.5 %.6.4.1 As an alternative mount the blowing chamber on load cells capable of determining the mass to within 0.5%.0.5 %.FIG. 1 Installed Thickness Test ChamberC1374 1826.5 Specimen Preparation
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13742018STANDARDTESTMETHODFORDETERMINATIONOFINSTALLEDTHICKNESSOFPNEUMATICALLYAPPLIEDLOOSEFILLBUILDINGINSULATIONPDF

链接地址:http://www.mydoc123.com/p-464400.html