ASTM C1318-2015 Standard Test Method for Determination of Total Neutralizing Capability and Dissolved Calcium and Magnesium Oxide in Lime for Flue Gas Desulfurization (FGD)《测定烟道气体脱.pdf
《ASTM C1318-2015 Standard Test Method for Determination of Total Neutralizing Capability and Dissolved Calcium and Magnesium Oxide in Lime for Flue Gas Desulfurization (FGD)《测定烟道气体脱.pdf》由会员分享,可在线阅读,更多相关《ASTM C1318-2015 Standard Test Method for Determination of Total Neutralizing Capability and Dissolved Calcium and Magnesium Oxide in Lime for Flue Gas Desulfurization (FGD)《测定烟道气体脱.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1318 15Standard Test Method forDetermination of Total Neutralizing Capability and DissolvedCalcium and Magnesium Oxide in Lime for Flue GasDesulfurization (FGD)1This standard is issued under the fixed designation C1318; the number immediately following the designation indicates the yea
2、r oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers analysis of magnesian, dolo-mit
3、ic and high-calcium limes for total neutralizing capabilityand dissolved major oxides. Dissolved calcium and magnesiumare the major species that neutralize acid under the conditionsof the test.1.2 The test conditions are chosen to measure the acid-neutralizing capacity of both calcium hydroxide and
4、magne-sium hydroxide contained in slaked lime. By controlling theneutralization pH at 6, magnesium hydroxide and magnesiumoxide are titrated in addition to calcium hydroxide fraction.1.3 This test method also determines the fraction of Mg ionspresent in the lime that will dissolve under lime flue ga
5、sdesulfurization (FGD) conditions. Because the Mg+ion altersFGD performance, it is important to know its concentration.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thes
6、afety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C25 Test Methods for Chemical
7、 Analysis of Limestone,Quicklime, and Hydrated LimeC50 Practice for Sampling, Sample Preparation, Packaging,and Marking of Lime and Limestone ProductsC51 Terminology Relating to Lime and Limestone (as usedby the Industry)C110 Test Methods for Physical Testing of Quicklime,Hydrated Lime, and Limeston
8、eC1301 Test Method for Major and Trace Elements in Lime-stone and Lime by Inductively Coupled Plasma-AtomicEmission Spectroscopy (ICP) and Atomic Absorption(AA)E11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Terminology3.1 DefinitionsUnless otherwise specified, for definitionsof t
9、erms used in these test methods refer to Terminology C51.4. Summary of Test Method4.1 Lime is slaked by boiling and is reacted with acid at apH and residence time similar to those found in full-scale FGDreaction tanks.4.2 A sample of lime is titrated with 1N hydrochloric acid,maintaining a pH of 6 f
10、or 30 min. After 30 min, the acidconsumption is recorded. The total neutralizing capacity iscalculated from the acid consumption and reported as CaO.Dissolved magnesium is determined by spectrometry or byEDTA titration and reported as percent dissolved MagnesiumOxide (as MgO).5. Significance and Use
11、5.1 There are existing lime-based flue gas desulfurizationunits in operation that require a method to measure the oxidesavailable for sulfur dioxide absorption. Dissolved magnesiumoxide varies among limes depending on the limestone sourcesand calcination conditions.6. Interferences6.1 Any substance
12、reacting with acid under the conditionsof the test will contribute to the total oxide and dissolved oxidevalues.6.2 Magnesium in forms other than MgO, which dissolveunder test conditions, may affect the dissolved MgO and totaloxide value.1This test method is under the jurisdiction of ASTM Committee
13、C07 on Limeand Limestone and is the direct responsibility of Subcommittee C07.05 on ChemicalTests.Current edition approved June 1, 2015. Published June 2015. Originallyapproved in 1995. Last previous edition approved in 2009 as C1318 95 (2009)1.DOI: 10.1520/C1318-15.2For referenced ASTM standards, v
14、isit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-
15、2959. United States17. Apparatus7.1 Digital Readout pH Meter, with combination electrodereadable to 0.01 pH units, or an autotitrator with an automatictemperature compensator capable of titrating to a presetendpoint (Note 1).NOTE 1Use of an automatic titrator is recommended.7.2 Stirrers and Stir Bar
16、s.7.3 Inductively Coupled Plasma Spectrometer or AtomicAbsorption Spectrometer, if not using EDTA titration.7.4 Filtering Funnel, Type AE glass fiber paper, volumetricflasks (size as needed), 500 mL volumetric flasks, and variousClass A pipettes.8. Reagents8.1 1.0 Normal Hydrochloric Acid, standardi
17、ze using pro-cedures in the section onAvailable Lime Index in Test MethodsC25.8.2 Deionized or Distilled Water, CO2free.8.3 Calcium and Magnesium Standard Solutions (commer-cially available or use the procedures in the section on Calciumand Magnesium Oxide (Alternative EDTATitration Method) inTest M
18、ethods C25.8.4 EDTA Standard Solution (0.4 %), standardize accordingto the procedure in the section on Calcium and MagnesiumOxide (Alternative EDTA Titration Method) in Test MethodsC25.9. Sample Preparation9.1 The sampling and grinding of any lime sample shall becarried out as rapidly as possible, s
19、o that the absorption ofmoisture and carbon dioxide is held to a minimum.9.2 The sample as received at the laboratory shall bethoroughly mixed and a representative sample with minimumweight of 100 g shall be taken and pulverized to pass a 300 m(No. 50) sieve for analysis. Conduct the sieve analysis
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13182015STANDARDTESTMETHODFORDETERMINATIONOFTOTALNEUTRALIZINGCAPABILITYANDDISSOLVEDCALCIUMANDMAGNESIUMOXIDEINLIMEFORFLUEGASDESULFURIZATIONFGD

链接地址:http://www.mydoc123.com/p-464206.html