ASTM C1370-2000(2012) Standard Test Method for Determining Chemical Resistance of Aggregates for Use in Chemical-Resistant Sulfur Polymer Cement Concrete and Other Chemical-Resista.pdf
《ASTM C1370-2000(2012) Standard Test Method for Determining Chemical Resistance of Aggregates for Use in Chemical-Resistant Sulfur Polymer Cement Concrete and Other Chemical-Resista.pdf》由会员分享,可在线阅读,更多相关《ASTM C1370-2000(2012) Standard Test Method for Determining Chemical Resistance of Aggregates for Use in Chemical-Resistant Sulfur Polymer Cement Concrete and Other Chemical-Resista.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1370 00 (Reapproved 2012)Standard Test Method forDetermining Chemical Resistance of Aggregates for Use inChemical-Resistant Sulfur Polymer Cement Concrete andOther Chemical-Resistant Polymer Concretes1This standard is issued under the fixed designation C1370; the number immediately fol
2、lowing the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test metho
3、d covers the determination of the effectsof selected environments on aggregates for use in manufactur-ing sulfur polymer cement concrete (SC) and other chemical-resistant polymer concretes.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are ma
4、thematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and
5、health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C904 Terminology Relating to Chemical-Resistant Nonme-tallic Materials2.2 National Institute of Standards and Technology:Avail-able from National Institute of Standards
6、 and Technology(NIST), 100 Bureau Dr., Stop 3460, Gaithersburg, MD 20899-3460.Handbook 44 Specifications Tolerances and other TechnicalRequirements for Commercial Weighing and MeasuringDevices3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method, referto Terminology C
7、904.4. Significance and Use4.1 The results obtained by this test method should serve asa guide in, but not as the sole basis for, selection of aggregatesfor use in sulfur polymer cement concrete and other chemical-resistant polymer concretes for a particular application. Noattempt has been made to i
8、ncorporate in the test method all thevarious factors that may affect the performance of a materialwhen subjected to actual service.4.2 This test method assists in determining whether aggre-gates are susceptible to attack by solutions in the environmentof intended use.4.3 This is not a test for perme
9、ability and results are not tobe interpreted as a measurement of, or indication of, perme-ability of the material tested.5. Apparatus5.1 Weighing Equipment, shall be capable of weighingmaterials or specimens to 60.3 % accuracy. The weighingequipment shall meet the National Institute of Standards and
10、Technology requirements for sensitivity and tolerances.NOTE 1In general, small quantities should not be weighed on largecapacity scales. In many applications, the smallest quantity weighed on ascale should be greater than about 10 % of the maximum capacity of thescale; however, this will vary with t
11、he performance characteristics of thescale and the required accuracy of the determination. Acceptable scalesused for weighing concrete materials preferably should weigh accuratelyto about 0.1 % of total capacity and the foregoing precaution is applicable.However, certain analytical and precision bal
12、ances are exceptions to thisrule and should weigh accurately to 0.001 %. Particular care must beexercised in measuring small quantities of material by determining thedifference between two much larger weights.5.2 Drying oven of sufficient size to accommodate theaggregate sample and capable of holdin
13、g the sample at atemperature of 230 6 10F (110 6 6C).5.3 Small Tools, including, but not limited to, items such as600-mL beakers, hot plate capable of holding sample andsolution at constant 140 6 4F (60 6 2C), desiccator, filterflask, funnel, and No. 1 qualitative filter papers.6. Materials Preparat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC137020002012STANDARDTESTMETHODFORDETERMININGCHEMICALRESISTANCEOFAGGREGATESFORUSEINCHEMICALRESISTANTSULFURPOLYMERCEMENTCONCRETEANDOTHERCHEMICALRESISTAPDF

链接地址:http://www.mydoc123.com/p-464383.html