ASTM C1280-2013a Standard Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing《外部石膏面板产品作为外保护壳应用的标准规格》.pdf
《ASTM C1280-2013a Standard Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing《外部石膏面板产品作为外保护壳应用的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1280-2013a Standard Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing《外部石膏面板产品作为外保护壳应用的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1280 13aStandard Specification forApplication of Exterior Gypsum Panel Products for Use asSheathing1This standard is issued under the fixed designation C1280; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers the minimum requirements forand methods of application of exterior gypsum panel productst
3、hat are specifically designed for use as a substrate for exteriorcladding.1.1.1 This specification does not cover gypsum panel prod-ucts that are specifically designed for interior applications.1.2 Details of construction for a specific assembly toachieve the required fire resistance shall be obtain
4、ed fromreports of fire-resistance tests, engineering evaluations, orlistings from recognized fire testing laboratories.1.2.1 This specification shall govern where it is morestringent (size or thickness of framing and size and spacing offasteners) than the fire-rated construction.1.3 Where sound cont
5、rol is required for a gypsum panelproduct assembly, the details of construction shall be inaccordance with the acoustical test report of an assembly thathas met the required acoustical value(s).1.3.1 This specification shall govern where it is morestringent (size or thickness of framing and size and
6、 spacing offasteners) than the sound-rated construction.1.4 Where resistance to racking loads or shear is requiredfor a gypsum panel product assembly, the details of construc-tion shall be in accordance with the racking or shear test reportof an assembly that has met the required racking or shearval
7、ue(s).1.4.1 This specification shall govern where it is morestringent (size or thickness of framing and size and spacing offasteners) than the racking or shear-tested construction.1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematica
8、lconversions to SI units that are provided for information onlyand are not considered standard.1.6 The text of this standard references notes which provideexplanatory material. These notes shall not be considered asrequirements of the standard.1.7 This standard does not purport to address all of the
9、safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C11 Terminology Relating to
10、Gypsum and Related BuildingMaterials and SystemsC954 Specification for Steel Drill Screws for theApplicationof Gypsum Panel Products or Metal Plaster Bases to SteelStuds from 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) inThicknessC955 Specification for Load-Bearing (Transverse and Axial)Steel Studs,
11、Runners (Tracks), and Bracing or Bridgingfor Screw Application of Gypsum Panel Products andMetal Plaster BasesC1002 Specification for Steel Self-Piercing Tapping Screwsfor the Application of Gypsum Panel Products or MetalPlaster Bases to Wood Studs or Steel StudsC1007 Specification for Installation
12、of Load Bearing (Trans-verse and Axial) Steel Studs and Related AccessoriesC1063 Specification for Installation of Lathing and Furringto Receive Interior and Exterior Portland Cement-BasedPlasterC1177/C1177M Specification for Glass Mat Gypsum Sub-strate for Use as SheathingC1278/C1278M Specification
13、 for Fiber-Reinforced GypsumPanelC1396/C1396M Specification for Gypsum Board2.2 U.S. Department of Commerce Publication:PS20 American Softwood Lumber Standard31This specification is under the jurisdiction of ASTM Committee C11 onGypsum and Related Building Materials and Systems and is the direct res
14、ponsibilityof Subcommittee C11.03 on Specifications for theApplication of Gypsum and OtherProducts in Assemblies.Current edition approved Nov. 15, 2013. Published January 2014. Originallyapproved in 1994. Last previous edition approved in 2013 as C1280 13. DOI:10.1520/C1280-13A.2For referenced ASTM
15、standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbin
16、s Ave., Philadelphia, PA 19111-5094, Attn: NPODS.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13. Terminology3.1 DefinitionsDefinitions shall be in accordance withTerm
17、inology C11.3.2 Definitions of Terms Specific to This Standard:3.2.1 exterior cladding, na permanent material or systemthat impedes the transmission of environmental elements to thegypsum panel products used as sheathing.3.2.2 fastener, nnails, staples, or screws used for applica-tion of the gypsum
18、panel product.3.2.3 framing member, nstuds, headers, bracing, andblocking that serve to receive the gypsum panel product.3.2.4 horizontal application, na synonym for perpendicu-lar application.3.2.5 parallel application, ngypsum panel product ap-plied with the factory edges parallel to the framing m
19、embers;a synonym for vertical application.3.2.6 perpendicular application, ngypsum panel productapplied with the factory edges at right angles to the framingmembers; a synonym for horizontal application.3.2.7 require, vto mandate by a force outside thisspecification, such as a building code, project
20、 specification,contract, or purchase order.3.2.8 specified, adjpertaining to a mandatory requirementof this specification or a referenced requirement.3.2.9 specify, vto mandate by an obligation of this stan-dard or a referenced document.3.2.10 vertical application, nsynonym for parallel appli-cation
21、.3.2.11 weather-resistive barrier, na temporarily exposedprotective membrane that is intended to impede the penetrationof environmental elements until the installation of a permanentexterior cladding.4. Exposure After Installation4.1 Gypsum sheathing board is a paper faced substrate thatshall be cov
22、ered by an exterior cladding or other weather-resistive barrier and is not intended for long-term exposure. Itshall not be exposed to the elements for more than 30 days afterit has been installed. Gypsum sheathing shall be covered witha weather-resistive barrier within 30 days if the exposure timewi
23、ll be more than 30 days.NOTE 1Some building codes require an additional weather-resistivebarrier. The exterior face paper of the sheathing shall be dry prior toapplication of the additional weather-resistive barrier.4.2 Water-Resistant Exterior Fiber-Reinforced GypsumSheathing Panels provide a subst
24、rate that shall be covered byan exterior cladding or other weather-resistive barrier and isnot intended for long-term exposure. Refer to manufacturersrecommendations for maximum exposure time. Water-Resistant Exterior Fiber-Reinforced Gypsum Sheathing Panelsshall be covered with a water-resistive ba
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12802013ASTANDARDSPECIFICATIONFORAPPLICATIONOFEXTERIORGYPSUMPANELPRODUCTSFORUSEASSHEATHING 外部 石膏

链接地址:http://www.mydoc123.com/p-464063.html