ASTM C1133-2003 Standard Test Method for Nondestructive Assay of Special Nuclear Material in Low Density Scrap and Waste by Segmented Passive Gamma-Ray Scanning《分段无源γ射线扫描法对低密度废料及残渣.pdf
《ASTM C1133-2003 Standard Test Method for Nondestructive Assay of Special Nuclear Material in Low Density Scrap and Waste by Segmented Passive Gamma-Ray Scanning《分段无源γ射线扫描法对低密度废料及残渣.pdf》由会员分享,可在线阅读,更多相关《ASTM C1133-2003 Standard Test Method for Nondestructive Assay of Special Nuclear Material in Low Density Scrap and Waste by Segmented Passive Gamma-Ray Scanning《分段无源γ射线扫描法对低密度废料及残渣.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1133 03Standard Test Method forNondestructive Assay of Special Nuclear Material in Low-Density Scrap and Waste by Segmented Passive Gamma-Ray Scanning1This standard is issued under the fixed designation C 1133; the number immediately following the designation indicates the year oforig
2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the transmission-corrected non-destruc
3、tive assay (NDA) of gamma-ray emitting specialnuclear materials (SNMs), most commonly235U,239Pu,and241Am, in low-density scrap or waste, packaged in cylin-drical containers. The method can also be applied to NDA ofother gamma-emitting nuclides including fission products.High-resolution gamma-ray spe
4、ctroscopy is used to detect andmeasure the nuclides of interest and to measure and correct forgamma-ray attenuation in a series of horizontal segments(collimated gamma detector views) of the container. Correc-tions are also made for counting losses occasioned by signalprocessing limitations (1-3).21
5、.2 There are currently several systems in use or underdevelopment for determining the attenuation corrections forNDA of radioisotopic materials (4-8). A related technique,tomographic gamma-ray scanning (TGS), is not included inthis test method (9,10).1.2.1 This test method will cover two implementat
6、ions ofthe Segmented Gamma Scanning (SGS) procedure: (1) IsotopeSpecific (Mass) Calibration, the original SGS procedure, usesstandards of known radionuclide masses to determine detectorresponse in a mass versus corrected count rate calibration thatapplies only to those specific radionuclides for whi
7、ch it iscalibrated, and (2) Efficiency Curve Calibration, an alternativemethod, typically uses non-SNM radionuclide sources todetermine system detection efficiency vs. gamma energy andthereby calibrate for all gamma-emitting radionuclides ofinterest (11). These two methods will be covered in detail
8、in theremainder of the main body of this test method and Annex A1.1.2.1.1 Efficiency Curve Calibration, over the energy rangefor which the efficiency is defined, has the advantage ofproviding calibration for many gamma-emitting nuclide forwhich half-life and gamma emission intensity data are avail-a
9、ble.1.3 The assay technique may be applicable to loadings up toseveral hundred grams of nuclide in a 208-L (55-gal) drum,with more restricted ranges to be applicable depending onspecific packaging and counting equipment considerations.1.4 Measured transmission values must be available for usein calc
10、ulation of segment-specific attenuation corrections at theenergies of analysis.1.5 A related method, SGS with calculated correction fac-tors based on sample content and density, is not included in thisstandard.1.6 The values stated in SI units are to be regarded as thestandard. The values given in p
11、arentheses are for informationonly.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limit
12、ations prior to use. Specific precau-tionary statements are given in Section 8.2. Referenced Documents2.1 ASTM Standards:C 982 Guide for Selecting Components for Energy-Dispersive X-Ray Fluorescence (XRF) Systems3C 1030 Test Method for Determination of Plutonium Isoto-pic Composition by Gamma Ray Sp
13、ectrometry3C 1128 Guide for Preparation of Working Reference Mate-rials for Use in the Analysis of Nuclear Fuel CycleMaterials3C 1156 Guide for Establishing Calibration for a Measure-ment Method Used to Analyze Nuclear Fuel Cycle Mate-rials3C 1207 Test Method for Nondestructive Assay of Plutoniumin
14、Scrap and Waste by Passive Neutron CoincidenceCounting3C 1210 Guide for Establishing a Measurement SystemQuality Control Program for Analytical Chemistry Labo-ratories within the Nuclear Industry3C 1458 Test Method for Nondestructive Assay of Pluto-nium, Tritium and241Am by Calorimetric Assay31This
15、test method is under the jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.10 on Nondestruc-tive Assay.Current edition approved July 10, 2003. Published September 2003. Originallyapproved in 1996. Last previous edition approved in 1996 as C
16、1133 96.2The boldface numbers in parentheses refer to the list of references at the end ofthis test method.3Annual Book of ASTM Standards, Vol 12.01.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.E 181 Test Methods for Detector Cali
17、bration and Analysisof Radionuclides42.2 ANSI Standards:5ANSI/IEEE 325 Test Procedures for Germanium Gamma-Ray DetectorsANSI N42.14 Calibration and Use of Germanium Spec-trometers for the Measurement of Gamma-Ray EmissionRates of Radionuclides2.3 NRC Regulatory Guides:6Regulatory Guide 5.9, Rev. 2,
18、Guidelines for GermaniumSpectroscopy Systems for Measurement of SpecialNuclear MaterialsRegulatory Guide 5.11, Rev. 1, Nondestructive Assay ofSpecial Nuclear Material Contained in Scrap and WasteRegulatory Guide 5.53, Rev. 1, Qualification, Calibration,and Error Estimation Methods for Nondestructive
19、 Assay3. Summary of Test Method3.1 The assay of the nuclides of interest is accomplished bymeasuring the intensity of one or more characteristic gammarays from each nuclide. Corrections are made for countrate-related losses and attenuation by the item. The appropriatemass or efficiency calibration t
20、hen provides the relationshipbetween observed gamma-ray intensity and nuclide content.3.2 Either of two distinct calibration methods can be used:3.2.1 Isotope Specific Calibration provides assay results foronly those radionuclides for which the SGS is specificallycalibrated. Calibration is performed
21、 using standards containingthe radionuclides to be assayed.3.2.2 Effciency Curve Calibration entails determination ofthe system detecton efficiency as a function of gamma rayenergy. Analysis of assay data consists of using the energy ofa peak to infer the emitting radionuclide, and then calculatingt
22、he radionuclide mass from the specific activity and the gammaemission intensity of the radionuclide, and the corrected countrate and detector efficiency at the peak energy.3.3 The assay item is rotated about its vertical axis andscanned segment by segment along that axis, thereby reducingthe effects
23、 of nonuniformity in both matrix density and nuclidedistribution (see Fig. 1).3.4 Count rate-dependent losses from pulse pile-up andanalyzer dead time are corrected for by electronic modules, aradioactive source, a pulser, or a combination of these.3.5 The average linear attenuation coefficient of e
24、ach hori-zontal segment is calculated by measurement of the transmittedintensity of an appropriate external gamma-ray source. Thesource is mounted directly opposite the gamma-ray detector, onthe far side of the assay item (see Fig. 1).3.6 Two conditions must be met to optimize SGS assayresults as fo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC11332003STANDARDTESTMETHODFORNONDESTRUCTIVEASSAYOFSPECIALNUCLEARMATERIALINLOWDENSITYSCRAPANDWASTEBYSEGMENTEDPASSIVEGAMMARAYSCANNING

链接地址:http://www.mydoc123.com/p-463487.html