《ASTM B810-2001a(2011) Standard Test Method for Calibration of Atmospheric Corrosion Test Chambers by Change in Mass of Copper Coupons《根据铜取样片质量变化校准大气腐蚀实验室的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B810-2001a(2011) Standard Test Method for Calibration of Atmospheric Corrosion Test Chambers by Change in Mass of Copper Coupons《根据铜取样片质量变化校准大气腐蚀实验室的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B810 01a (Reapproved 2011)Standard Test Method forCalibration of Atmospheric Corrosion Test Chambers byChange in Mass of Copper Coupons1This standard is issued under the fixed designation B810; the number immediately following the designation indicates the year oforiginal adoption or, i
2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the calibration of atmosphericcorrosion test chambers for
3、electrical contacts that produce anadherent film of corrosion product on copper, such as a testcomprised of a mixture of flowing gases that react with copper.1.2 This test method is not applicable to tests wherecorrosion products may be removed from a copper surfaceduring the test by fluids.1.3 This
4、 test method is not applicable to tests whereairborne solid or liquid material may be deposited on a coppersurface during the test, as in a test which includes particulatessuspended in the atmosphere.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are i
5、ncluded in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to become familiarwith all hazards including those identified in the appropriateMaterial Safety Data Sheet (MSDS) for
6、 this product/materialas provided by the manufacturer, to establish appropriatesafety and health practices, and determine the applicability ofregulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B845 Guide for Mixed Flowing Gas (MFG) Tests forElectrical Contacts3. Summary o
7、f Test Method3.1 Copper coupon samples of a well-defined size areprepared and each is labeled for identification. All suchcoupons are cleaned by a standard process. Each coupon isweighed and the value is recorded. All coupons are exposed tothe corrosion test for a specified time. The coupons areremo
8、ved from the test and weighed and the new values arerecorded. The change in weight for each coupon is calculated.The coupons are subjected to additional analysis as appropriateto determine the composition and thickness of any filmspresent on the surface.4. Significance and Use4.1 Electrical devices
9、that contain electrical contacts gener-ally contain some copper-based materials. Atmospheric corro-sion of copper parts in such devices often occurs in serviceenvironments. A quantitative measure of the effect of alaboratory corrosion test on copper permits assessment of theseverity of the test. In
10、addition, corrosion tests may be definedin terms of their effect on copper; this test method provides away of comparing one test against a standard defined else-where, or allows a comparison of the performance of a testover a period of time. Although this test method provides for arelatively simple
11、check of a test, the user is advised thatadditional analysis of the test chamber ambient is generallyrequired to reproduce test conditions.4.2 Atmospheric corrosion tests are used on a variety ofmaterials besides copper. Care should be exercised in drawingconclusions about the effects on such materi
12、als of apparentlyequivalent tests if the composition of gases or experimentalconditions are different. The primary use of this calibration testmethod is to assure correlation among nominally identicaltests.5. Apparatus5.1 Racks or Fixtures suitable for holding the copper cou-pons in the test chamber
13、 are required. Make these fixtures froma material that is not attacked by the corrosion test. The fixturesshall be designed to:5.1.1 Hold the coupons in a vertical orientation,5.1.2 Hold the coupons so that they do not show anyperceptible motion when observed with the unaided eye duringthe test,5.1.
14、3 Cover less than 5 % of the entire coupon surface area,5.1.4 Touch the coupon only with electrically insulatingparts and,1This test method is under the jurisdiction of ASTM Committee B02 onNonferrous Metals and Alloys and is the direct responsibility of SubcommitteeB02.11 on Electrical Contact Test
15、 Methods.Current edition approved Oct. 1, 2011. Published October 2011. Originallyapproved in 1991. Last previous edition approved in 2006 as B810 01a (2006).DOI: 10.1520/B0810-01AR11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm
16、.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.5 Allow free circulation of the ambient on both sides ofth
17、e coupon.5.2 In general, design all parts of the fixture to permitmaximum circulation of the ambient around the couponsurfaces. The size and positioning of the holding fixturesdepends on the chamber size. Section 7 of this test methodgives requirements on the number and spacing of coupons; theholdin
18、g fixtures must be designed to comply with theserequirements.5.3 Balance, with a capacity of at least 2 g and a resolutionof 5 g is required. Maintain the ambient in the vicinity of thebalance between 20 and 50 % relative humidity.5.4 Fume Hood, to conduct the chemical cleaning procedureof the coupo
19、ns is required.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society3where such specifications
20、 are available. Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.7. Procedure7.1 Use the requirements listed in 7.1.1 through 7.1.3 todetermine the number of copper coupon spe
21、cimens to beprepared.7.1.1 For chambers with cubic working volumes, use thelength of an edge to determine the number and placement ofcoupons in accordance with the following rules. For chamberswith an edge dimension of 0.9 m or less, construct a referencegrid with three equally spaced lines in each
22、direction with theouter lines 0.1 m from the chamber wall and the third linecentered between the outer lines. Place a coupon at eachintersection of grid lines (27 coupons required). For chamberswith an edge dimension of 0.9 m to 1.4 m, construct a referencegrid with four equally spaced lines in each
23、 direction. The outerlines are placed 0.1 m from the chamber wall. Place a couponat each intersection of grid lines (64 coupons required). Forchambers with a maximum edge dimension greater than 1.4 mbut less than 2.0 m, construct a reference grid with five equallyspaced lines in each direction. The
24、outer lines are placed 0.1 mfrom the chamber wall. Place a coupon at each intersection ofgrid lines (125 coupons required).7.1.2 For rectangular chambers with non-cubic workingvolumes, the guidelines for each dimension of the chamberalong the x, y, and z axes of the chamber shall follow theappropria
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB8102001A2011STANDARDTESTMETHODFORCALIBRATIONOFATMOSPHERICCORROSIONTESTCHAMBERSBYCHANGEINMASSOFCOPPERCOUPONS

链接地址:http://www.mydoc123.com/p-462353.html