ASTM B533-1985(2009) Standard Test Method for Peel Strength of Metal Electroplated Plastics《测量塑料表面金属镀层抗撕裂强度的标准试验方法》.pdf
《ASTM B533-1985(2009) Standard Test Method for Peel Strength of Metal Electroplated Plastics《测量塑料表面金属镀层抗撕裂强度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B533-1985(2009) Standard Test Method for Peel Strength of Metal Electroplated Plastics《测量塑料表面金属镀层抗撕裂强度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 533 85 (Reapproved 2009)Endorsed by AmericanElectroplaters SocietyEndorsed by NationalAssociation of Metal FinishersStandard Test Method forPeel Strength of Metal Electroplated Plastics1This standard is issued under the fixed designation B 533; the number immediately following the des
2、ignation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method gives two pr
3、ocedures for measuring theforce required to peel a metallic coating from a plasticsubstrate.2One procedure (Procedure A) utilizes a universaltesting machine and yields reproducible measurements that canbe used in research and development, in quality control andproduct acceptance, in the description
4、of material and processcharacteristics, and in communications. The other procedure(Procedure B) utilizes an indicating force instrument that is lessaccurate and that is sensitive to operator technique. It issuitable for process control use.1.2 The tests are performed on standard molded plaques.This
5、method does not cover the testing of production electro-plated parts.1.3 The tests do not necessarily measure the adhesion of ametallic coating to a plastic substrate because in properlyprepared test specimens, separation usually occurs in theplastic just beneath the coating-substrate interface rath
6、er thanat the interface. It does, however, reflect the degree that theprocess is controlled.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pract
7、ices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Document2.1 ASTM Standards:3E4 Practices for Force Verification of Testing Machines3. Summary of Test Method3.1 A properly prepared standard test specimen, called aplaque, is copper electroplated, with no addi
8、tional metalcoating. The coated plaque is either tested as is, or it isconditioned by a low-temperature bake and then tested. Thecoating is cut through to the plastic substrate in a way thatforms two strips of coating (see Fig. 1). Each strip is peeledfrom the substrate at a right angle using an ins
9、trument thatindicates the force required to separate it from its substrate.4. Significance and Use4.1 The force required to separate a metallic coating from itsplastic substrate is determined by the interaction of severalfactors: the generic type and quality of the plastic moldingcompound, the moldi
10、ng process, the process used to preparethe substrate for electroplating, and the thickness and mechani-cal properties of the metallic coating. By holding all othersconstant, the effect on the peel strength by a change in any oneof the above listed factors may be noted. Routine use of the testin a pr
11、oduction operation can detect changes in any of theabove listed factors.4.2 The peel test values do not directly correlate to theadhesion of metallic coatings on the actual product.4.3 When the peel test is used to monitor the coatingprocess, a large number of plaques should be molded at onetime fro
12、m a same batch of molding compound used in theproduction moldings to minimize the effects on the measure-ments of variations in the plastic and the molding process.5. Apparatus5.1 Procedure AA tension testing machine that has self-aligning grips and that has a loading range that includes theforces t
13、o be measured, 5 to 200 N, shall be used to separate thecoating from the substrate, and measure the force required. Themachine shall meet the verification requirements of PracticesE4.4,5The speed of separation of the crossarms of the machineshall be adjusted to give a separation rate of 25 6 3 mm/mi
14、n.The machine shall automatically and continuously record on achart the load on one coordinate and the amount of peel on theother coordinate. The amount of peel may be obtained fromcalculation, using a known chart speed.1This test method is under the jurisdiction ofASTM Committee B08 on Metallicand
15、Inorganic Coatings and is the direct responsibility of Subcommittee B08.08.03on Decorative Coatings.Current edition approved Sept. 1, 2009. Published December 2009. Originallyapproved in 1970. Last previous edition approved in 2004 as B533 85 (2004).DOI: 10.1520/B0533-85R09.2This test is also known
16、as the Jacquet Test. A detailed treatment of the test hasbeen published by Saubestre et al in Plating, Vol 52, 1965, p. 982.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, r
17、efer to the standards Document Summary page onthe ASTM website.4The sole source of supply of the Instron universal testing machine known to thecommittee at this time is Instron Corp., Canton, MA.5If you are aware of alternative suppliers, please provide this information toASTM International Headquar
18、ters. Your comments will receive careful consider-ation at a meeting of the responsible technical committee1, which you may attend.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Procedure BA spring-loaded, force-indicating instr
19、u-ment with a measurement range that includes the force to bemeasured, 5 to 200 N, shall be used to measure the forcerequired to separate the coating. The indicated force shall beaccurate to 610 %.6. Sampling6.1 A sampling procedure is not applicable to this testmethod.7. Test Specimen7.1 Perform th
20、e test using a flat, molded plastic plaque suchas shown in Fig. 1. Plaque dimensions may vary up to 610 %provided that the edges of slit peel strips are not closer than 11mm from any plaque edge.8. Conditioning8.1 Condition the electroplated plaques requiring condition-ing by baking for1hinanair-cir
21、culating oven operated at70 6 3C. Place the plaques in the oven in a way that permitsfree circulation of air around all surfaces of the plaques. Allowthe conditioned plaques to cool to room temperature and thentest them within 1 h. Test the plaques that do not requireconditioning within 30 to 60 min
22、 following the coatingprocess.NOTE 1The separation strength of an unconditioned plaque willchange with time. The separation strength of a conditioned plaque maychange with time after conditioning.9. Procedure9.1 Mold the required number of plaques using the specifiedmolding compound and molding proc
23、edure.NOTE 2When the test is used as a control of the coating process,commercially prepared plaques can be used.9.2 Clean, activate, and electroplate the plaques as speci-fied. The thickness of the metallic coating in the test area (seeFig. 1) shall be 40 6 4 m.NOTE 3It is necessary to have a ductil
24、e copper coating to perform thistest. The thickness and uniformity of thickness of the metallic coatingdirectly influence the peel strength; therefore, in order to standardize thistest, the coating thickness is specified. If a different coating thickness isused, the results will not be comparable to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB53319852009STANDARDTESTMETHODFORPEELSTRENGTHOFMETALELECTROPLATEDPLASTICS 测量 塑料 表面 金属 镀层 撕裂 强度 标准

链接地址:http://www.mydoc123.com/p-461486.html