ASHRAE FUNDAMENTALS SI ADD AND CORR-2013 Additions and Corrections.pdf
《ASHRAE FUNDAMENTALS SI ADD AND CORR-2013 Additions and Corrections.pdf》由会员分享,可在线阅读,更多相关《ASHRAE FUNDAMENTALS SI ADD AND CORR-2013 Additions and Corrections.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、A.1ASHRAE HANDBOOKAdditions and CorrectionsThis report includes additional information, and technical errorsfound between June 15, 2010, and April 1, 2013, in the SI editionsof the 2010, 2011, and 2012 ASHRAE Handbook volumes. Occa-sional typographical errors and nonstandard symbol labels will becor
2、rected in future volumes. The most current list of Handbookadditions and corrections is on the ASHRAE web site(www.ashrae.org).The authors and editor encourage you to notify them if youfind other technical errors. Please send corrections to: HandbookEditor, ASHRAE, 1791 Tullie Circle NE, Atlanta, GA
3、 30329, ore-mail mowenashrae.org. 2010 RefrigerationCh. 1. All existing references to Table 19 should be to Table 20. Allexisting references to Table 20 should be to Table 19.p. 19.2, Eq. (4). Change twoto xwo.p. 19.7, Eq. (10). Change to t to (to t)2.2011 HVAC Applications(CD only) Table of Content
4、s, p. 2. Replace second instance of“Building Operations and Management” with “General Applications.”Contributors List. For Chapter 4, add Dennis Wessel, KarpinskiEngineering.p. 5.7, 2nd col., 2nd bulleted point. Change 15 m/s to 0.15 m/s.p. 28.8, 1st col. Under U.S. Evolutionary Power Reactor (USEPR
5、),delete “0.125 in. of water” and the parentheses around “30 Pa.”p. 35.4, end of 2nd para. It should be J= I for all conditions.p. 35.5, Eq. (17). The equation should be Fsg= (1 cos 6)/2.p. 35.10, 2nd col., 3rd para. from bottom. The slope should be0.82/0.12 = 6.78.p. 35.22, Example 7, Solution. The
6、 load collector ratio should useEq. (41).p. 35.27, Symbols. Delete the second definition for Aap.p. 36.9, Table 4. Replace the table with the one on p. A.2.p. 48.20, 2nd col. For frequency range #1, consult Table 13 for Af.In definitions for Eq. (10), refer to Table 12 for Da.p. 50.18, Example 4, So
7、lution. Change “2.2 mL/” to “2.2 mL/s.”p. 51.2, Eq. (10). Change Ta to Ta.p. 51.8, Example 3, Solution. The equation for a hydronic systemshould be as follows:O = = $324/yr (T10.7)pp. 55.12-13, Eqs. (27), (28), (30), and (31). For all four equations,the denominators of the last two terms should be b
8、 and a, not 2b and2a. Also, for Eq. (31), change the first + sign to a sign.p. 60.6, Fig. 9. Replace the figure with the one provided above.2012 HVAC Systems and Equipmentpp. 7.26-27, Figs. 36 and 38. The SI versions of these figures areprovided above.p. 19.2, Table 1. For the rightmost four columns
9、, the headingsshould be +1500, 1500, +2500, and 2500 Pa.p. 26.4, 1st col., top. Units for the results for w2and w4should bekg/kg of dry air.p. 40.19, Table 1. In fifth column, change value in row 6 to 0.0345,and in row 7 to 0.0334.p. 41.3, Fig. 3. Replace parts B and C of the graphic with the hori-z
10、ontal polymer tube shown on p. A.3.p. 44.8, Table 1. In both equations for flow and pressure, change theminuses to equals signs.p. 51.13, Table 4. For hour 6, Storage should be 1400 kW.200 26.8 0.0324 130100-0.85 0.90 -Fig. 9 Typical Layout of UVGI Fixtures for Patient Isolation Room(First et al. 19
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAEFUNDAMENTALSSIADDANDCORR2013ADDITIONSANDCORRECTIONSPDF

链接地址:http://www.mydoc123.com/p-454776.html