ASHRAE 90444-2009 Particulate and Gaseous Contamination in Datacom Environments《针对数据通信环境中气体与颗粒污染物》.pdf
《ASHRAE 90444-2009 Particulate and Gaseous Contamination in Datacom Environments《针对数据通信环境中气体与颗粒污染物》.pdf》由会员分享,可在线阅读,更多相关《ASHRAE 90444-2009 Particulate and Gaseous Contamination in Datacom Environments《针对数据通信环境中气体与颗粒污染物》.pdf(105页珍藏版)》请在麦多课文档分享上搜索。
1、 Particulate and Gaseous Contamination in Datacom Environments 2009, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted withou
2、t ASHRAEs prior written permission.This publication was prepared in cooperation with TC 9.9, Mission Critical Facilities,Technology Spaces and Electronic Equipment.Any updates/errata to this publication will be posted on the ASHRAE Web site at www.ashrae.org/publicationupdates.American Society of He
3、ating, Refrigeratingand Air-Conditioning Engineers, Inc.Particulate and Gaseous Contaminationin Datacom EnvironmentsISBN 978-1-933742-60-12009 American Society of Heating, Refrigeratingand Air-Conditioning Engineers, Inc.1791 Tullie Circle, NEAtlanta, GA 30329www.ashrae.orgAll rights reserved.Printe
4、d in the United States of AmericaPrinted on post-consumer waste using soy-based inks.Cover photograph used with permission of Crispin R. Semmens.ASHRAE has compiled this publication with care, but ASHRAE has not investigated, and ASHRAE expresslydisclaims any duty to investigate, any product, servic
5、e, process, procedure, design, or the like that may bedescribed herein. The appearance of any technical data or editorial material in this publication does not constituteendorsement, warranty, or guaranty by ASHRAE of any product, service, process, procedure, design, or the like.ASHRAE does not warr
6、ant that the information in the publication is free of errors, and ASHRAE does not neces-sarily agree with any statement or opinion in this publication. The entire risk of the use of any information inthis publication is assumed by the user.No part of this book may be reproduced without permission i
7、n writing from ASHRAE, except by a reviewer whomay quote brief passages or reproduce illustrations in a review with appropriate credit; nor may any part of thisbook be reproduced, stored in a retrieval system, or transmitted in any way or by any meanselectronic, photo-copying, recording, or otherwit
8、hout permission in writing from ASHRAE. Requests for permission shouldbe submitted at www.ashrae.org/permissions._Library of Congress Cataloging-in-Publication DataParticulate and gaseous contamination in datacom environments.p. cm. - (ASHRAE datacom series ; bk. 8)Includes bibliographical reference
9、s and index.Summary: “Provides the reader with information they need to maintain a high level of IT equipment depend-ability and availability by identifying datacom equipment susceptibility to particulate and gaseous contamina-tion and the operational impact, as well as strategies for prevention, co
10、ntrol, contamination testing, and analysis“-Provided by publisher.ISBN 978-1-933742-60-1 (softcover)1. Clean rooms. 2. Data processing service centers-Protection. 3. Electronic data processing-Equipment and supplies-Protection. 4. Air filters. 5. Dust control. 6. Contamination (Technology) 7. Decont
11、amination (from gases, chemicals, etc.) I. American Society of Heating, Refrigerating and Air-Conditioning Engineers. TH7694.P37 2009697.9316-dc222009016962ASHRAE STAFFSPECIAL PUBLICATIONSMark OwenEditor/Group Managerof Handbook and Special PublicationsCindy Sheffield MichaelsManaging EditorJames Ma
12、dison WalkerAssociate EditorAmelia SandersAssistant EditorElisabeth ParrishAssistant EditorMichshell PhillipsEditorial CoordinatorPUBLISHING SERVICESDavid SoltisGroup Manager of Publishing Servicesand Electronic CommunicationsJayne JacksonPublication Traffic AdministratorPUBLISHERW. Stephen Comstock
13、ContentsAcknowledgments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ixChapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 General Description of Particulate Matter . . . . . . . . . . . . . . . . . . . 21.2 Gene
14、ral Description of Gaseous Contamination . . . . . . . . . . . . . . 31.3 Contaminant Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.4 How Contaminants Settle on Equipment . . . . . . . . . . . . . . . . . . . . 51.5 Differences Between Human Health and Datacom Equipm
15、ent Concerns . . . . . . . . . . . . . . . . . . . . . . . . 71.6 Overview of Chapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Chapter 2 Datacom Equipment Vulnerability . . . . . . . . . . . . . . . . . . 112.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . .
16、 . . . . . . . . . . . . . . . . . 11 2.2 Reasons for Increased Concern . . . . . . . . . . . . . . . . . . . . . . . . . 122.2.1 Restriction of Hazardous Substances. . . . . . . . . . . . . . . . 122.3 Airborne Contamination Ingress Mechanisms . . . . . . . . . . . . . . . 122.4 Particulate Matter
17、Properties and Effects . . . . . . . . . . . . . . . . . . 122.4.1 Areas Susceptible to Particulate Matter Accumulation . . . 132.5 Gaseous Contamination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.5.1 Gas Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18、 . . 19Chapter 3 Industry Specifications and Guidelines. . . . . . . . . . . . . . 233.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233.2 Published Guidelines and Limits for Particulate Matter . . . . . . . . 24vi Contents3.2.1 GR-63-CORE/NEBSTelec
19、ommunications . . . . . . . . . . .243.2.2 IEC 60721-3-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253.2.3 Federal Standard 209E-100,000 (M6.5) and ISO 14644-1 Class 8. . . . . . . . . . . . . . . . . . . . . . . . . .263.3 Published Guidelines and Limits for Gaseous Contami
20、nants . . . .28Chapter 4 Prevention and Control. . . . . . . . . . . . . . . . . . . . . . . . . . . .314.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .314.2 Prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21、 . . .324.2.1 Risk Assessment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324.2.2 Facility Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .334.2.3 Computer Room Design. . . . . . . . . . . . . . . . . . . . . . . . . . .334.2.4 Computer Room Construction
22、. . . . . . . . . . . . . . . . . . . . . .354.2.5 HVAC System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .404.2.6 Fire Suppression System . . . . . . . . . . . . . . . . . . . . . . . . . .454.2.7 Mechanical Malfunction . . . . . . . . . . . . . . . . . . . . . . . . . . .45
23、4.2.8 Operational Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . .474.3 Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .494.3.1 Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .494.3.2 Equipment Fail
24、uresSevere . . . . . . . . . . . . . . . . . . . . . . .494.3.3 Equipment FailuresNonsevere . . . . . . . . . . . . . . . . . . . .504.3.4 Periodic Maintenance Plan. . . . . . . . . . . . . . . . . . . . . . . . .504.3.5 Nonroutine Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAE904442009PARTICULATEANDGASEOUSCONTAMINATIONINDATACOMENVIRONMENTS 针对 数据通信 环境 气体 颗粒 污染物 PDF

链接地址:http://www.mydoc123.com/p-454472.html