1、1. SCOPE .1.1 This specification covers one type of panoramic telescope which provides four-power magnification and a ten-degree field of view. equipped with numerical counters which indicate deflection settings and corrections. reference point. actively illuminated. 2. APPLICABLE DOCUMENTS It is A
2、resettable counter provides angular readings from a The reticle pattern and the counter numerals are radio- 2.1 The following documents, of the issue in effect on date of invitation for bids or request for proposal, form a part of this specifi- cation to the extent specified herein. .- SPECIFICATION
3、S Military MIL-0-13830 ._ MIL-F-13926 . 2 I. . - . ._ MIL-P-14232 MIL-1-45607 STANDARDS Mil i tary MIL-STD-105 MIL-STD-109 DRAWINGS Optical Components for Fire Control Instruments, General Specification Governing the Manufacture, Assembly and Inspection Fire Control Materiel; General Speci- fication
4、 Governing the Manufacture and Inspection Parts, Equipment and Tools for Army Materiel, Packaging and Packing of Inspection Equipment, Supply and Maintenance of Sampling Procedures and Tables for Quality Assurance Terms and Definitions Inspection by Attributes U.S. Army, Fra-ford dsenal Fll730267 Te
5、lescope, ?anorami-: M113E1 FSC 1240 THIS DOCUMENT CONTAINS - fL PAGES. / Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. PACKAGING.DATA SHEET L 11730267 Packagini: of Telescope, Panoramic: Ml13El. (Copies of specifications, standnrda , drawings nii
6、d p:tckrigi ng data sheets required by suppliers in connection with speci i c procurenient functions should be obtained from the procuring activity or as directed by the contracting officer.) 2.2 -Other publications.- The following document forms a part of this specification to the extent specified
7、herein. indicated, the issue in effect on date of invitation for bids or request for proposal shall apply. Unless otherwise DEFENSE SUPPLY AGENCY MANUAL DSAM 4158.8 Radioactive Commodities in the DOD Supply Systems (Copies ofIISAM4158.8 may be obtained from the Superintendent of Documents, U.S. Gove
8、rnment Printing Office, Washington, D.C. 20402.) 3. REQUIREMENTS 3.1 Regulations pertaining to radioactive devices.- Marking, identification, handling, and shipping of radioactive devices shall be in accordance with DSAM 4158.8. 3.2 Fabrication.- The telescope shall be manufactured in accordance wit
9、h Drawing F11730267 . 3.3 General specification.- The following requirements of MIL-F- 13926 shall be met: a. Order of precedence. b. Dimensions and.tolerances. c. Inorganic protective surface finishes. d. Part identification and marking. e. Workmanship. . 3.4 Environmental. 3.4.1 Storage temperatur
10、es.- The telescope shall show no evidence of physical failure due to being thermally stabilized at -80 and +160 Fahrenheit (F) . 3.4.2 Operating temperatures.- The telescope shall meet the applicable requirements of 3.9 while thermally stabilized at -40 and +150F. Provided by IHSNot for ResaleNo rep
11、roduction or networking permitted without license from IHS-,-,-_- 3.4.3 Vibration.- The telescope shall be vibrated in a vertical plane at a constant frequency of thirty cycles per second with an amplitude of 1/16 inch (U8 inch total excursion).for a period of five minutes plus or minus fifteen seco
12、nds. evidence of physical failure. Subsequent.to vibration there shall be no 3.5 Cleanliness.- The telescope shall meet the cleanliness requre- ments of MTL-0-13830 and there shall be no more than 2 particles of dirt visible on the reticle. of the areas equivalent to a size 10 dig. surfaces which in
13、terferes with observation or adversely affects image The area of each particle shall nog be in excess There shall be no dirt on other quality. 3.6 Sealinp;. 3.6.1 Optical assembly portion.- The optical assembly portion of the telescope shall be capable of sustaining an internal pressure of 5.0 f 0.1
14、pounds per square inch gage (psig), with less than 0.2 psig loss, for a minimum period of two hours. 3.6.2 Counterbox assembly portion.- The counterbox assembly portion of the telescope shall be capable of sustaining an internal pressure of 2.0 4 0.2 psig, with less than 0.2 psig loss, for a minimum
15、 period of two hours. 3.7 Accuracy. , 3.7.1 Collimation.- With the flat mounting surface of the telescope in a horizontal plane the azimuth counter reading 3200 mils, the reset counter shall read 3200 mils when the left (i,) and right (R) gunners aid counters are set at O0 and OO. The eyepiece elbow
16、 shall be positioned in detent and shall be perpendicular to the plane of the telescope locating keyways. With the head cover openlthe forward line of sight shall.be to the left of the eyepiece elbow and shall be parallel to the plane of the telescope 16cating keyways and horizontal to :the :seating
17、 sursace. . : ._ 3.7.1.1 Open sight.- With the telescope positioned as in 3.7.1, the line of sight of the open sight shall be horizontal within plus or minus 10 mils and parallel-in deflection (azimuth) to the optical lines of sight within plus or minus 10 mils. 3.7.1.2 Eyepiece elbow movement.- Mov
18、ement of the eyepiece elbow from its midpoint to the left and right extremes of travel shall not cause a deviation in excess of one degree. 3,7.2 Image tilt.- The image of a vertical target line shall be vertical within one degree throughout one revolution of the head. 3.7.2.1 Image wander.- The wan
19、der of the reticle image measured at the eyepiece shall not exceed 4 degrees in diameter for 2 full revolutions 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-i MIL-T-50382 12 9999906 032bO 3 of thc head. 3.7.3 Plunib travel.- With the telescope p
20、ositioned ab: in 3.7.1, the line of sight shall follow a plumb line (starting with the line of sight horizontal and in coincidence with the plumb line) within 0.5 mil when the head prism is depressed a minimum of 300 mile and elevated 300 mils from the horizontal when checked at any deflection setti
21、ng. 3.7.4 Parallelism of reticle and image.- With the telescope position- ed as in 3.7.1, the vertical reticle line shall be parallel to the image of a plumb line within 30 minutes of arc at any deflection setting. 3.7.5 Level travel.- With. the telescope positioned as in 3.7.1, the line of sight sh
22、all not deviate from a horizontal target line by more than 1.0 mil (total excursion of 2 mils) when the head is rotated through two revolutions. 3.7.5.1 Lift.- Vertical displacement of the line of sight due to reversing direction of rotation of the head shall not exceed 1.0 mil. 3.7.6 Deflection err
23、or. 3.7.6.1 Throughout 800 mil steps.- Error at deflection readings in 800 mil steps throughout two full revolutions of the head in one direction shall not exceed 1.0 mil including backlash. the greatest positive error and the greatest negative error shall not exceed 1.0 mil. mil azimuth counter rea
24、ding and the reset counter for any one number shall not exceed 0.25 mil. The total spread between The total error, excluding backlash, between the 6400 3.7.6.2 Throughout 15 mil steps.- Error at deflection readings in 15 mil steps taken at eight random positions throughout one full revolution of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT503821970TELESCOPEPANORAMICM113A1M113A1 全景 望远镜 PDF

链接地址:http://www.mydoc123.com/p-448706.html