1、sMIL-T-4938L 58 7797906 OL63b03 5 mt MIL-T-49381(ER) 2 July 1980 MILITARY SPECIFICATION TEST SET, THERMAL SIGHT, TS-3681/VSG-2 This specification is approved for use by USAERADCOM, Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1.1 Scop
2、e. This specification covers the Test Set, Thermal Sight, TS-36811 VSG-2. 2. APPLICABLE DOCUMENTS 2.1 Issues of documents. The following documents of the issue in effect on date of invitation for bids or request for proposal, form a part of this specification to the extent specified herein. SPECIFIC
3、ATIONS FEDERAL PPP-B- 5 6 6 PPP-B-636 PPP-B-665 PPP-B-676 MILITARY MIL-P- 116 MIL-P- 11268 MIL-E- 17 5 5 5 MIL-T-28800 - Boxes, Folding, Paperboard - Boxes, Shipping, Fiberboard - Boxes, Paperboard, Metal Edged and Components - Boxes, Setup - Preservation-Packaging, Methods of - Parts, Materials, an
4、d Processes Used in 7 Electronic and Electrical Equipment, Electronic Equipment Accessories, and Repair Parts, Packaging and Packing of Electronic Equipment, General Specification for - Test Equipment for Use With Electrical and Beneficial comments (reconmendations, additions, deletions) and any per
5、tinent data which may be of use in improving this document should be addressed to: Hq, USA Electronics Research and Development Command, ATTN: DRDEL-E, 2800 Powder Mill Road, Adelphi, MD 20783 by using the self-addressed Standard- ization Document Improvement Proposal (DD Form 1426) appearing at the
6、 end of this document or by letter. FSC 5855 THIS DOCUMENT CONTAINS ,I!, PAGES Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-49381 (ER) STANDARDS MILITARY MIL-STD-105 MIL-STD-129 MIL-STD-252 MIL-STD-454 MIL-STD-461 MIL-STD-462 MIL-STD-810 DRA
7、WINGS DLSM-B-804916 MIL-T-473L 58 rn 7777906 0363604 7 i7 w 1 - Sampling Procedures and Tables for - Marking for Shipment and Storage - Classification of Visual and Mechanical Inspection by Attributes Defects for Equipment, Electronic, Wired, and Other Devices tronic Equipment tics, Requirements for
8、 Equipment tics, Measurement of - Standard General Requirements for Elec- - Electromagnetic Interference Characteris- - Electromagnetic Interference Characteris- - Environmental Test Methods - Test Set, Sight, Thermal, Tank Mounted AN/VSG-2 (Copies of specifications, standards, drawings, and publica
9、tions required by contractors in connection with specific procurement functions should be ob- tained from the procuring activity or as directed by the contracting officer.) 3. REQUIREMENTS 3.1 Description. The Test Set, Thermal Sight, TS-3681/VSG-2, herein known as the test set, shall support mainte
10、nance of the Sight, Thermal, Tank Mounted, AN/VSG-2 equipment at the direct support and general support (DS/GS) maintenance environments. The test set shall consist of two containers. MIL-T-28800 shall be used to define the general requirements of the Collimator, Type I, class 4, style T, and type I
11、, class 4, style C for the test station. a. 58-inch collimator. Container number 1. b. Line Replaceable Unit (LRU) test station. Container number 2. 3.2 Construction. The test set shall be constructed in accordance with DLSM-B-804916 or as specified in the contract. 3.3 First article. When specified
12、 in the contract (see 6.21, the contractor shall furnish test sets for first article inspections. 3.4 Parts, materials, and processes. Parts, materials, and processes shall be as specified herein and as shown on the applicable drawings. Parts, materi- als, and processes not specified shall be select
13、ed in accordance with MIL-P- 11268. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-* * L I - MIL-T-4738L 58 3977706 0363605 7 MIL-T-49 38 1 (ER) 3.5 Components. The test set consists of two holding fixtures that will provide a stable mount for the
14、 TTS LRUs and two containers that house the following components. Container number one houses the collimator with its temperature controller, spindle and drum assembly and the input power cable. Container number two houses the LRU test station, test target reticle combiner, LED viewer telescope, PWB
15、 puller, spanner wrench, and the TTS interconnect cables. with their applicable drawings, specifications, and as specified herein. Each component of the two containers shall be constructed in accordance 3.6 Preconditioning. Each test set shall be subjected to a 48 hour precon- ditioning prior to del
16、ivery. 3.7 Operation. 3.7.1 Power. 3.7.1.1 Collimator. The collimator shall operate from a 115 Vac, 50/60 Hz single phase power source. 3.7.1.2 Test station. The LRU test station shall operate from a direct current source from a minimum of 18 volts to a maximum of 30 volts. The maxi- mum peak curren
17、t drain at any time during operation of the test station shall not exceed 25 amperes. 3.7.2 Collimator output. The collimator shall contain a temperature con- troller and spindle and drum assembly which when used will provide a combina- tion of six (6) collimated infrared and visible targets to the
18、unit under test sufficient to derive the performance status. The temperature controller and target source assembly shall create a calibrated temperature difference be- tween its blackbody source and the target array. at the resolution frequency shall be 0.45, 20.045C for the MRT taggets. the other t
19、argets, the temperature difference shall be 4.50, 20.45 C. This temperature difference For 3.7.3 Test station electrical protection. The test station shall be equipped with devices to protect the system from reverse polarity, overcur- rent, short circuit and under/over voltages, on the input power s
20、ide of the test station. These devices shall be located 3.7.4 Test station output characteristics. The test station shall have two modes of operation, STANDBY and ON. In the STANDBY mode, the test station shall provide the following outputs: a. 120, +10 Vac (under load), 400, 220 Hz, 2-phase, square
21、 wave. b. 18 to30 Vdc. c. 5.0, - +0.5 Vdc (for operation of BITE-circuitry). In the ON mode, all of the voltages listed for the STANDBY mode shall be pro- vided plus the following additional voltages: d. 18 to 30 Vdc (this in addition to the 18 to 30 Vdc in STANDBY). e. Eight regulated voltages as s
22、hown below. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-473L 5 7777706 OL63bOb O Output voltage (Vdc 1 MIL-T-49381 (ER) Maximum continuous current Minimum ripple rejection (amperes) (dB) NOTE: Input ripple voltage equals 3.0 V p-p at O to
23、 35 kHz. +10.5 20.5 +10.0 +0.5 -9.0 70.5 +1O.O 78.0 -0.5 +5.0 20.3 +15.0 70.5 -5.0 +Oe3 -15.0 50.5 1.0 1.0 1.0 2.0 0.750 O. 500 1.0 0.750 4 60 50 50 50 50 50 50 50 3.7.5 Test target/reticle combiner. The test target/reticle combiner shall combine a visible target from the collimator with the reticle
24、 image for reticle focus. It shall also divide and separate the target, providing a double image for adjusting IR magnification. 3.7.6 LED viewer telescope. The LED viewer telescope shall allow visual evaluation of the LED image from the TTS head assembly. 3.7.7 Controls. 3.7.7.1 Collimator controls
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT493811980TESTSETTHERMALSIGHTTS3681VSG2TS3681VSG2 瞄准 测试 装置 PDF

链接地址:http://www.mydoc123.com/p-448703.html