1、15 December 1997 SUPERSEDING 19 March 1986 MIL-V-4672OB(AT) PERFORMANCE SPECIFICATION VALVE, SOLENOID This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers two types of 24-volt 0, solenoid actuated, hydrauli
2、c directionat control valves with an operating pressure of 3000 pounds per square inch (psi) (20 685 kilopascals va) (see 6. i). 1.2 Classification. Valves should be of the following types, as specified (see 6.2): Type I Type II - Two position, four-way, rated flow capacity: 6 gaiions per - Two posi
3、tion, two-way, rated flow capacity: 3.5 gai/min minute (gdrnk) (0.38 liters per second (L/s). (0.22 L/s). Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Tank-automotive and Armaments
4、Command, ATTN: AMSTA-TR-EBLUE, Warren, MI 48397-5000 by using the Standardization Document Improvement Proposal (DD Form 1426), appearing at the end of this document, or by letter. AMSC N/A FSC 2590 DISTRIBUTION STATEMENT A. Approved for public release, distribution is unlimited. Provided by IHSNot
5、for ResaleNo reproduction or networking permitted without license from IHS-,-,-0b 204721b 4T7 MIL-PRF-4672OC 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents in other sections of
6、 this specification or recommended for additional Somation or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet d specified requirement documents cited in sections 3 and 4 of this specification, whether or not they
7、 are listed. 2.2 Government documents. 2.2.1 Specifications. standards. and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specised herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Dep
8、artment of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). STANDARDS DEPARTMENT OF DEFENSE MIL-STD-462 MIL-STD-8 1 O - Measurement of Electromagnetic Interference Characteristics, Test Methods Standard for (see 4.3. i). - Environmen
9、tal Test Methods and Engineering Guidelines (see 4.3.1). (Unless otherwise indicated, copies of the above specifications and standards are available fiom the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 191 11-5094.) 2.2.2 other Government documents. drawing
10、s. and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specied herein. Unless otherwise specified. the issues are those cited in the Solicitation. NCLEAR REGULATORY COMMISSION (NRC) Code of Federal Regulations (CFR)- Title
11、 10, Parts 30 and 40. (Application for copies should be addressed to the Superintendent of Documents, U.S. Government Printing Wce, Washington, DC 20402.) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-U 0b 2047217 333 M MIL-PRF-4672OC DRAWINGS DE
12、PARTMENT OF DEFENSE 9008233 9098673 - Valve, Solenoid (Type I) (Interface). - Valve, Solenoid (Type II) (Inte&ace). (Copies of these drawings are available from the U.S. Army Tank-automotive and Armaments Command, ATTN: AMSTA-TR-EBLUE, Warren, MI 48397-5000.) 2.3 Non-Government publications. The fol
13、lowing documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoD
14、ISS are the issues of the documents cited in the solicitation (see 6.2). AMERICAN SOCIETY FOR TESTING AND MATEWS (ASTM) ASTM B117 - Standard Practice for Operating Salt Spray (Fog) Apparatus OD Adopted). (Application for copies should be addressed to the American Society for Testing and Materials (A
15、STM), 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this specification takes precedence. Nothing in this document, however, supersedes applicable laws and re
16、gulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), first article samples shall be subjected to fust article inspection in accordance with 4.1.1. 3.2 Desim. materials. and manufacturing processes. Unless otherwise specified, the desig
17、n, materiais, and mandacturing process selection shall be the prerogative of the contractor as long as all articles submitted to the Government hlly meet the operating, interface, ownership and support, and operating environment requirements specified. (Asbestos, cadmium and radioactive materials sh
18、d not be used in this item. Radioactive material is defined by Title 1 O, CFR, Parts 30 and 40, and other radioactive materials in which the specific activity is greater than 0.002 microcuries per gram or the activity per item equals or exceeds 0.01 microcuries). 3 Provided by IHSNot for ResaleNo re
19、production or networking permitted without license from IHS-,-,-MIL-PRF-4672OC 3.2.1 Metals. All metals used in valve construction, except metal which is in constant contact with the hydraulic fluid, shall be of corrosion-resisting type or shall be adequately protected to resist corrosion during the
20、 normal service life of the valve and shall meet the requirements of salt spray 3.6.4. 3.2.1.1 Dissimilar metals. Dissimilar metals shall be protected from galvanic corrosion. 3 2.2 Recycled. recovered. or environmentally preferable materials. Recycled, recovered, or environmentally preferable mater
21、ials should be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.3 ODerating requirements. The valve shall meet the following performance requirements. 3.3.1 Operati
22、ng time. 3.3.1.1 Type I. The valve shall operate (change port interconnection) in not more than 0.05 second (s), with 18 V irect current (dc) applied. 3.3.1.2 Type II. The valve shall operate (change port interconnection) in not more than 0.07 s, with 18 Vdc applied. 3.3.2 Operating pressure. The va
23、lve shall operate with any pressure fiom 250 psi (1 724 Ba) applied to any port except return, and shall operate at any pressure within a pressure differential range, between the pressure port and rem port, from 250 psi to 3000 psi (1724 kPa to 20 685 kPa) (retuni port applicable to type I only) whi
24、le Using a conforming hydraulic fluid (see 6.3). 3.3.3 Operab voltwe. The valve shall operate at any voltage within a range of 18 to 30 Vdc, with operating pressure applied. 3.3.4 Operating current. The valve shall require no more than 1 .O ampere (A) at 24 Vdc to operate. 3.3.5 Rated flow and messu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF46720C1997VALVESOLENOID 电磁阀 PDF