ARMY MIL-PRF-12647 D-1996 PUMP INFLATING-DEFLATING HAND-OPERATED AIR SINGLE-CYLINDER PLUNGER《可进行加减压的手动单缸气柱塞泵》.pdf
《ARMY MIL-PRF-12647 D-1996 PUMP INFLATING-DEFLATING HAND-OPERATED AIR SINGLE-CYLINDER PLUNGER《可进行加减压的手动单缸气柱塞泵》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-12647 D-1996 PUMP INFLATING-DEFLATING HAND-OPERATED AIR SINGLE-CYLINDER PLUNGER《可进行加减压的手动单缸气柱塞泵》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、I INCH-POUND I MIL-PRF-12647D 26 Febmarv 1996 SUPERSEDING 3 July 1980 MIL-P-12647C PERFORMANCE SPECIFICATION PUMPS, INFLATING-DEFLATING, HAND-OPERATED, AIR, SINGLE-CYLINDER PLUNGER This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope
2、. This specification covers hand-operated, air inflation-deflation pumps with a single-cylinder plunger. I. 1.2 Classifica tion. The pumps should be of the following types and sizes, as specified (see 6.2 and 6.3). Type I - Foot Model (see Drawing TA1321 1E9597). Type II - Hand Model. Size 1 - 6-314
3、 inch cylinder length (see Drawing TA13211E9598). Size 2 - 10 inch cylinder length (see Drawing TA13211E9599). Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Tank-automotive and Armam
4、ents Command, ATTN: AMSTA-TR-EBLUE, Warren, the Standardization Document Improvement Proposal (DD Form I this document, or by letter. - 1 . AMSC NIA FSC $320 2. DIST Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without l
5、icense from IHS-,-,- MIL-PRF-32647D 9999706 2035022 35T MIL-PRF-12647D 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommend
6、ed for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 o ther Go
7、vernment documents. dra wi nm. - and D U blications . The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWINGS ME TA13211E9597 TA1321 1E9598 T
8、A1321 1E9599 - Pump, Inflating-Deflating, Hand Operated: Foot Model - Pump, Inflating-Deflating, Hand Operated: Hand Model - Pump, Inflating-Deflating, Hand operated: Hand Model, (Cap and Base, Aluminum). Size 1. Size 2. (Copies of these drawings are available from the U.S. Army CECOM RDE Center, Be
9、lvoir Division Pipe, 10315 Gridley Road, STE. 220, ATTN: AMSEL-LC-ED-BC, Fort Belvoir, VA 22060-5849.) 2.3 Non-Government publications . The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted
10、are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSUASQC Z1.4 - Sampling Procedures an
11、d Tables for Inspection by Attributes (DoD Adopted). (Application for copissdd be ddiesSedl -fificari National Staard Institute, 11 West 42nd Street, New York, NY 10036.) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-12647D SOCIETY OF AUT
12、OMOTIVE ENGINEERS, INC. (SAE) ANSVSAE AS478 - Identification Marking Methods (DoD Adopted). (Application for copies should be addressed to Society of Automotive Engineers, Inc., 400 Commonwealth Drive, Warrendale, PA 15096.) 2.4 Order of precede nce. In the event of a conflict between the text of th
13、is document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subject
14、ed to first article inspection in accordance with 4.2. 3.2 Materials. Materials shall be in accordance with top assembly Drawing TA13211E9597 for the type I foot model pump; top assembly Drawing TA13211E9598 for the type II, size 1 hand model pump; and top assembly Drawing TAl3211E9599 for the type
15、II, size 2 hand model pump; and as specified herein. For materials not specified herein the contractor shall select the materials, but the materials shall be capable of meeting all of the operational and environmental requirements specified herein. Recovered materials shall be used to the maximum ex
16、tent possible (see 4.4.1). 3.2.1 Lubn cation. Components of the pump shall be lubricated as specified on the drawings. 3.2.1.1 Type I. food model pump . The type I, foot model pump shall conform to TA13211E9597. The pump shall be furnished with 2 hose assemblies as shown on the applicable drawings.
17、the overall length of the hoses shall be 48 inches (in.) or 84 in., as specified (see 6.2); with each hose assembly furnished with a hose adapter as shown on the drawings. 3.2.1.2 T -p. h ,* 3.2.1.2.1 S ize 1. pump. The size 1 hand model pump shall conform to TA1321 1E9598, and shall be furnished wi
18、th a hose assembly, 10.31 in. overall3 length, and 2 hase-adapters, as shown on the drawings. 3.2.1.2.2 S ize 2. pu- . The size 2 hand model pump shall conform to TA1321.1E9599, and shall be furnished with a hose assembly, 10.31 in. overall length, and 2 hose adapters, as shown on the drawings. 3 Pr
19、ovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-lt2647D W 9999706 2035024 122 MIL-PRF-12647D 3.3 Design. 3.3.1 Drawings. All three designs shall conform to the drawings specified in 3.2. These drawings are end product drawings. No deviation fro
20、m the prescribed dimensions or tolerances is permissible without prior approval of the contracting officer. Where tolerances could cumulatively result in incorrect fits, the contractor shall provide tolerances within those prescribed on the drawings to insure correct fit, assembly, and operation of
21、the pumps. Any data (shop drawings, layouts, flow sheets, processing procedures, etc.) prepared by the contractor or obtained from a vendor to support fabrication and manufacture of the production item shall be made available, upon request, for inspection by the contracting officer or his designated
22、 representative. No deviation from the prescribed dimensions or tolerances is permissible without prior approval of the contracting officer (see 4.4.2). 3.3.2 Conosion. The pumps shall be fabricated from compatible materials that are inherently corrosion-resistant and not subject to high-metallic/ga
23、lvanic electrolysis (see 4.4.1 and 4.4.2). 3.4 Performance. 3.4.1 Overall performawe . The pumps shall show no evidence of damage or malfunction when subjected to the tests specified in 4.5 at ambient temperatures. 3.4.2 Environmental. 3.4.2.1 Storage. The pumps shall meet the overall performance re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便