ARMY A-A-59126 B-2012 TERMINALS FEEDTHRU (INSULATED) AND TERMINALS STUD (INSULATED AND NONINSULATED).pdf
《ARMY A-A-59126 B-2012 TERMINALS FEEDTHRU (INSULATED) AND TERMINALS STUD (INSULATED AND NONINSULATED).pdf》由会员分享,可在线阅读,更多相关《ARMY A-A-59126 B-2012 TERMINALS FEEDTHRU (INSULATED) AND TERMINALS STUD (INSULATED AND NONINSULATED).pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be emailed to usarmy.APG.cerdec.mbx.standardization-crxmail.mil Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil/ AMSC N/A F
2、SC 5940 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. . INCH-POUND A-A-59126B 28 March 2012 SUPERSEDING A-A-59126A 31 May 2011 COMMERCIAL ITEM DESCRIPTION SHEET TERMINALS, FEEDTHRU (INSULATED) AND TERMINALS, STUD (INSULATED AND NONINSULATED) The General Services A
3、dministration has authorized the use of this commercial item description (CID) as a replacement for MIL-T-55155 for all federal agencies. 1. SCOPE 1.1 Scope. This CID covers the requirements for insulated feedthru terminals and insulated and noninsulated stud terminals. 2. CLASSIFICATION. Items proc
4、ured under this CID shall be identified by part numbers as follows: AA59126/XX 0 H 01 CID Sheet Identifier Insulation Color Conductor Material Item Number And Finish 2.1 CID Sheet Identifier. The CID sheet identifier shall consist of the number of the CID, a slash (/) , and a two digit number denoti
5、ng the CID sheet covering the item. 2.2 Insulation Color. The insulation color is indicated by a single digit in accordance with Table I. For noninsulated terminals or natural color (other than polytetrafluoroethylene) insulated terminals, the letter “X” shall be used in place of the single digit. 2
6、.3 Conductor Material and Finish. The conductor material and finish is identified by a single letter (see 3.3.1). For example, “H” defines a brass terminal, tin-lead plated in accordance with SAE-AMS-P-81728, 0.0003 inch minimum thickness. 2.4 Item Number. The item number is indicated by a two-digit
7、 number. Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59126B 2 Table I. Insulation color. Symbol Insulation Color 0 Black 1 Brown 2 Red 3 Orange 4 Yellow 5 Green 6 Blue 7 V
8、iolet 8 Gray 9 White 3. SALIENT CHARACTERISTICS 3.1 CID Sheets. The individual item requirements shall be as described herein and in accordance with the applicable CID sheet. In the event of any conflict between the requirements of this CID and the CID sheet, the latter shall govern. 3.2 Materials.
9、Unless otherwise specified herein, materials shall conform to the manufacturers specifications/standards. The use of recycled or reclaimed materials is acceptable provided that all requirement of this CID are met (see 4.1). Materials shall be fungus inert. 3.3 Design and Construction. The terminals
10、shall conform to the manufacturers design and construction. The dimensions shall be in accordance with the individual CID sheet. 3.3.1 Conductor Material and Finish. The conductor material and finish shall be in accordance with one of the following. When so constructed and finished, the terminals sh
11、all be solderable. 3.3.1.1 Bronze. The conductor material shall be bronze and finished with one of the following. Copper underplate is not required. B - Tin-lead plated in accordance with SAE-AMS-P-81728, 0.0003 inch minimum thickness C - Hot solder dipped using Sn60/Pb40 Solder per IPC J-STD-006, 0
12、.0001 inch minimum thickness D - Tin-lead electrodeposited in accordance with ASTM B 545, 0.0003 inch minimum thickness. The minimum lead content shall be 3 percent. Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking perm
13、itted without license from IHS-,-,-A-A-59126B 3 3.3.1.2 Brass. The conductor material shall be brass and finished with one of the following. Copper underplate of 0.0001 inch minimum thickness is required. H - Tin-lead plated in accordance with SAE-AMS-P-81728, 0.0003 inch minimum thickness I - Hot s
14、older dipped using Sn0/Pb40 Solder per IPC J-STD-006, 0.0001 inch minimum thickness J - Tin-lead electrodeposited in accordance with ASTM B 545, 0.0003 inch minimum thickness. The minimum lead content shall be 3 percent. 3.3.2 Mounting Bases. Mounting bases shall be constructed of brass and shall be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA59126B2012TERMINALSFEEDTHRUINSULATEDANDTERMINALSSTUDINSULATEDANDNONINSULATEDPDF

链接地址:http://www.mydoc123.com/p-440278.html