《ANSI NEMA C136.10-2010 For Roadway and Area Lighting Equipment - Locking-Type Photocontrol Devices and Mating Receptacles - Physical and Electrical Interchangeability and Testing.pdf》由会员分享,可在线阅读,更多相关《ANSI NEMA C136.10-2010 For Roadway and Area Lighting Equipment - Locking-Type Photocontrol Devices and Mating Receptacles - Physical and Electrical Interchangeability and Testing.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers Association$16, their existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. T
2、he American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American Nat
3、ional Standards Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this standard. Caution Notice: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards
4、Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by National Electrical Manufacture
5、rs Association 1300 North 17th Street, Rosslyn, VA 22209 Copyright 2010 by National Electrical Manufacturers Association All rights reserved including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic
6、 Works, and the International and Pan American Copyright Conventions. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. Printed in the United States of America ANSI C136.10-2010 Revision o
7、f ANSI C136.10-2006 ii CONTENTS 1 Scope . 1 2 References . 1 2.1 Normative References 1 2.2 Informative References . 1 3 Definitions . 1 4 Mechanical Requirements 4 4.1 Plug Type 4 4.2 Receptacle Type . 4 4.3 Sealing 4 4.4 Receptacle Dimensions 5 4.5 Receptacle Mounting 5 4.5.1 Orientation . 5 4.5.2
8、 Horizontal Mounting 5 4.6 Receptacle Marking 5 4.7 Shorting Cap . 5 4.8 Non-Shorting Cap . 5 4.9 Enclosure 5 5 Electrical Requirements . 5 5.1 Photocontrol 5 5.2 Receptacle and Plug . 6 5.3 Receptacle Heat-Cycle Test . 6 6 Environmental Requirements . 6 6.1 Ambient Temperature Range 6 6.2 Plug-Rece
9、ptacle Interface Temperature . 6 6.3 Environmental Tests . 6 7 Dielectric Performance Requirements 6 7.1 Grounding 6 7.2 Dielectric Withstand 6 7.3 Surges . 7 7.3.1 Photocontrol 7 7.3.2 Shorting and Non-Shorting Cap 7 8 Marking, Materials, and Finishes 7 8.1 Marking 7 8.2 Low Temperature Impact 7 8.
10、3 Atmospheric Conditions 7 8.4 Temperature Rise . 7 8.5 Flammability 7 9 Ratings . 8 9.1 Load Ratings . 8 9.2 Surge Protection Rating 8 10 Operating Requirements 8 10.1 Photocontrol Calibration 8 10.2 Light Levels . 8 10.2.1 Measurement Procedure . 8 10.2.2 Rate of Change of Illumination Levels 8 10
11、.2.3 Light Level Test Equipment . 9 10.3 Specifications 9 11 Qualification Test Procedures 9 11.1 Receptacle Heating Test . 9 11.1.1 Setup . 9 11.1.2 Conditioning 9 11.1.3 Procedure 9 11.1.4 Pass/Fail Criteria . 9 ANSI C136.10-2010 Revision of ANSI C136.10-2006 iii 11.2 Humidity Test 10 11.3 Rain Te
12、st . 10 11.4 Surge Test . 10 11.4.1 Standard Surge . 10 11.4.2 Test Equipment Calibration . 10 11.4.3 Test Procedure (Standard Surge, 6,000 Volts) . 10 11.4.4 Test Procedure (Low Voltage) 10 11.4.5 Test Procedure (High-Level Surge, 10,000 Volts) 11 11.5 Continuous Current Load Test 11 11.6 Load Test
13、 11 11.6.1 Load Test Supply 11 11.6.2 Test Cycle . 11 11.6.3 Incandescent Lamp Load 11 11.6.4 Capacitor Load 11 11.6.5 Incandescent Lamp Load Test 11 11.6.6 Capacitor Load Test 11 ANSI C136.10-2010 Revision of ANSI C136.10-2006 iv This page intentionally left blank. 1 AMERICAN NATIONAL STANDARD ANSI
14、 C136.10-2010 For Roadway and Area Lighting Equipment Locking-Type Photocontrol Devices and Mating Receptacles Physical and Electrical Interchangeability and Testing 1 Scope This standard covers the following roadway and area lighting equipment, which may be physically and electrically interchanged
15、to operate within established values: a) Locking type photocontrol, herein referred to as photocontrol. b) Locking type mating receptacle, herein referred to as receptacle. c) Shorting and non-shorting caps. 2 References 2.1 Normative References This standard incorporates by reference provisions fro
16、m other publications. These normative references are cited at the appropriate places in the text, and the publications are listed below. For undated references, the latest edition of the publication referred to applies (including amendments). ANSI C136.2-2004 American National Standard for Roadway a
17、nd Area Lighting Equipment Luminaire Voltage Classification ANSI/IEEE C62.41 IEEE Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits ANSI/UL 773-2002 Plug-In Locking Type Photocontrols for Use with Area Lighting IESNA LM-48-01 Guide for Testing the Calibration of Locking-Type Ph
18、otoelectric Control Devices Journal of the Illuminating Engineering Society, Vol. 21, No. 2, Summer 1992, pp 54-56 UL 94-1996 Tests for Flammability of Plastic Materials for Parts in Devices and Appliances 2.2 Informative References This standard is to be used in conjunction with the following publi
19、cation. The latest edition of the publication applies (including amendments). IESNA DG-13-1998 Selection of Photocontrols for Outdoor Lighting Applications 3 Definitions 3.1 fail-off photocontrol: A photocontrol designed such that the load remains off when the most likely failure occurs. 3.2 fail-on
20、 photocontrol: A photocontrol designed such that the load remains on when the most likely failure occurs. 3.3 fast acting photocontrol: Turn-off and/or turn-on response time is between 0.5 and 5.0 seconds. ANSI C136.10-2010 Revision of ANSI C136.10-2006 2 3.4 follow current: The current from the con
21、nected power source that flows through an arrester during and following the passage of discharge or surge current. 3.5 horizontal illuminance (HI): Luminous flux per unit area (density) normal to a horizontal plane. 3.6 instant acting photocontrol: Turn-off and/or turn-on response time is less than
22、0.5 seconds. 3.7 inverse ratio photocontrol: A photocontrol with the turn-off value lower than the turn-on value. 3.8 maximum surge energy absorbed (for rating purposes only): The maximum allowable surge energy that the photocontrol can absorb without changing its operating characteristics. This is
23、based on a single 10 x 1000 s current waveform. 3.9 non-shorting cap: A device that provides an open circuit between line and load when a photocontrol is not used (also called an open cap). 3.10 part night photocontrol: A photocontrol that turns the load off for some portion of a night in accordance
24、 with one or more of the following options: 3.10.1 fixed time photocontrol: A photocontrol that turns the load on at dusk and off at a time interval (X) that is either factory preprogrammed or determined by a user operated selector device on the photocontrol. 3.10.2 real clock time photocontrol: A p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSINEMAC136102010FORROADWAYANDAREALIGHTINGEQUIPMENTLOCKINGTYPEPHOTOCONTROLDEVICESANDMATINGRECEPTACLESPHYSICALANDELECTRICALINTERCHANGEABILITYANDTESTINGPDF

链接地址:http://www.mydoc123.com/p-437485.html