《AASHTO T 79-2012 Standard Method of Test for Flash Point with Tag Open-Cup Apparatus for Use with Material Having a Flash Point Less Than 93 (200.pdf》由会员分享,可在线阅读,更多相关《AASHTO T 79-2012 Standard Method of Test for Flash Point with Tag Open-Cup Apparatus for Use with Material Having a Flash Point Less Than 93 (200.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Standard Method of Test for Flash Point with Tag Open-Cup Apparatus for Use with Material Having a Flash Point Less Than 93C (200F) AASHTO Designation: T 79-12 American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-2a T 7
2、9-1 AASHTO Standard Method of Test for Flash Point with Tag Open-Cup Apparatus for Use with Material Having a Flash Point Less Than 93C (200F) AASHTO Designation: T 79-12 1. SCOPE 1.1. This method covers the procedure for the determination of flash points by the tag open-cup apparatus of cutback asp
3、halts having flash points of less than 93C (200F). The sample is placed in the tester and heated at a slow and constant rate. A small test flame is passed at a uniform rate in a level plane across the cup at specified intervals. The flash point is the lowest temperature at which application of the t
4、est flame causes the vapor at the surface of the liquid to flash. Note 1Specifications commonly designate the Cleveland Open-Cup method (T 48) for asphalt binders and cutback asphalts having flash points above 79.5C (175F). 1.2. The values stated in SI units are to be regarded as the standard. 1.3.
5、This test may involve hazardous materials, operations, and equipment. This test does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and determine the applicability of regulatory limi
6、tations prior to use. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standard: T 48, Flash and Fire Points by Cleveland Open Cup 2.2. ASTM Standard: E1, Standard Specification for ASTM Liquid-in-Glass Thermometers 3. APPARATUS 3.1. Tag Open-Cup TesterConsisting of the following parts. The parts must conform to
7、 the dimensions shown and have the additional characteristics as noted. (See Figure 1.) 3.1.1. Copper BathEquipped with a constant-level overflow placed to maintain the bath liquid level 3.2 mm (1/8in.) below the ridge of the glass cup. 3.1.2. Thermometer HolderSupplied with the tester. It shall sup
8、port the thermometer firmly in a vertical position. 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-2a T 79-2 AASHTO 3.1.3. Glass Test CupConstructed of molded clear glass, annealed, heat-resistant, a
9、nd free from surface defects. (See Figure 2.) 3.1.4. Filling Level GaugeFor proper adjustment of the liquid level in the cup. This device shall be made of suitable metal at least 3.2 mm (1/8in.) thick, with two projections for adjusting the liquid level in the glass cup to 3.18 0.25 mm (0.125 0.01 i
10、n.) below the top edge or rim of the cup. Also, the holes in the leveling device may be used to adjust the size of the test flame and for gauging the height of the taper above the edge of the cup. (See Figure 3.) 3.1.5. “Micro” or Small Gas BurnerOf suitable dimensions for heating the bath. A screw
11、clamp may be used to help regulate the gas. A small electric heater controlled by a variable power transformer may also be used. 3.1.6. Ignition TaperA small, straight, blowpipe-type gas burner. The tip of the taper should be approximately 1.6 mm (1/16in.) in diameter. The ignition taper should be m
12、aintained in a fixed horizontal plane above the test cup by means of a swivel device so that the test flame passes on the circumference of a circle having a radius of at least 152 mm (6 in.). A comparison bead, 4.0 mm (5/32in.) in diameter, may be mounted in a convenient spot. If mounted on the igni
13、tion taper, a portion of the tip of the taper, 1.6 mm (1/16in.) in diameter, shall extend at least 3 mm (1/8in.) beyond the bead. 3.1.7. Draft ShieldA suitable shield may be made of two rectangular sheets of noncombustible material, 610 by 710 mm (24 by 28 in.), fastened together along the 710 mm (2
14、8 in.) side, preferably by hinges. A triangular sheet, 610 by 610 by 860 mm (24 by 24 by 34 in.), is fastened by hinges to one of the lateral sheets to form a top when the shield is open. The interior of the draft shield shall be painted flat black. 3.2. ThermometerA Pensky-Martens, low-range thermo
15、meter capable of measuring 5 to 110C (20 to 230F) and conforming to the requirements for an ASTM Thermometer No. 9C (9F) as prescribed in ASTM E1 shall be used. 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicabl
16、e law.TS-2a T 79-3 AASHTO Dimensional Equivalents Millimeters Inches 71.4 213/1680.9 33/16174.6 67/8Note: All dimensions are shown in millimeters unless otherwise noted. Figure 1Tag Open-Cup Tester 2030405080.9174.671.4SampleGlass Test CupIgnition TaperCopper BathMicro or SmallGas BurnerThermometerO
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOT792012STANDARDMETHODOFTESTFORFLASHPOINTWITHTAGOPENCUPAPPARATUSFORUSEWITHMATERIALHAVINGAFLASHPOINTLESSTHAN93200PDF

链接地址:http://www.mydoc123.com/p-418349.html