1、Standard Method of Test for Saybolt Viscosity AASHTO Designation: T 72-10 (2015) American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-2a T 72-1 AASHTO Standard Method of Test for Saybolt Viscosity AASHTO Designation: T
2、72-10 (2015) 1. SCOPE 1.1. This test method covers the empirical procedures for determining the Saybolt Universal or Saybolt Furol viscosities of petroleum products at specified temperatures between 21 and 99C (70 and 210F). A special procedure for waxy products is indicated. Note 1T 201 and ASTM D4
3、45 are preferred for the determination of kinematic viscosity. These methods require smaller samples and less time, and provide greater accuracy. Kinematic viscosities may be converted to Saybolt viscosities by use of the tables in ASTM D2161. It is recommended that viscosity indexes be calculated f
4、rom kinematic rather than Saybolt viscosities. 1.2. The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the respon
5、sibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: R 66, Sampling Asphalt Materials T 59, Emulsified Asphalts T 201, Kinematic Viscosity of A
6、sphalts (Bitumens) 2.2. ASTM Standards: D117, Standard Guide for Sampling, Test Methods, and Specifications for Electrical Insulating Oils of Petroleum Origin D445, Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) D2161, Standard P
7、ractice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity E1, Standard Specification for ASTM Liquid-in-Glass Thermometers E11, Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves E102/E102M, Standard Test Method for Saybolt Furol V
8、iscosity of Bituminous Materials at High Temperatures 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-2a T 72-2 AASHTO 3. TERMINOLOGY 3.1. Definitions: 3.1.1. Furolan acronym of “Fuel and Road Oils.”
9、3.1.2. Saybolt Furol viscositythe corrected efflux time in seconds of 60 mL (2 oz) of sample flowing through a calibrated Furol orifice under specified conditions. The viscosity value is reported in “Saybolt Furol seconds,” abbreviated “SFS,” at a specified temperature. 3.1.3. Saybolt Universal visc
10、ositythe corrected efflux time in seconds of 60 mL (2 oz) of sample flowing through a calibrated Universal orifice under specified conditions. The viscosity value is reported in “Saybolt Universal seconds,” abbreviated “SUS,” at a specified temperature. 4. SUMMARY OF TEST METHOD 4.1. The efflux time
11、 in seconds of 60 mL of sample, flowing through a calibrated orifice, is measured under carefully controlled conditions. This time is corrected by an orifice factor and reported as the viscosity of the sample at that temperature. 5. SIGNIFICANCE AND USE 5.1. This test method is useful in characteriz
12、ing certain petroleum products, as one element in establishing uniformity of shipments and sources of supply. 5.2. See ASTM D117 for applicability to mineral oils used as electrical insulating oils. 5.3. The Saybolt Furol viscosity is approximately one tenth of the Saybolt Universal viscosity and is
13、 recommended for characterization of petroleum products such as fuel oils and other residual materials having Saybolt Universal viscosities greater than 1000 s. 5.4. Determination of the Saybolt Furol viscosity of asphalt materials at higher temperatures is covered by ASTM E102/E102M. 6. APPARATUS 6
14、.1. Saybolt Viscometer and Bathas shown in Figure 1 and described in Annex A2. 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-2a T 72-3 AASHTO Note: All dimensions are in millimeters (inches). Figure
15、 1Saybolt Viscometer with Universal and Furol Orifice 32.5 0.5Level of Liquidin BathUniversal TipOverflowRim29.7 0.2(1.28 0.02)(1.17 0.01)MIN. 6 (0.25)1.765 0.015(0.0695 0.0006)12.25 0.10(0.482 0.004)125 1.0(4.92 0.04)88.0(3.47)MIN.9.00(0.354) MIN.3.0 0.2(0.12 0.01)3.150 0.020(0.1240 0.0008)12.25 0.
16、10(0.482 0.004)4.3 0.2(0.17 0.01)Bottom of BathCorkStopperFurol Tip 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-2a T 72-4 AASHTO 6.2. Withdrawal Tubeas shown in Figure 2, or other suitable device.
17、 Note: All dimensions are in millimeters (inches). Figure 2Withdrawal Tube for Use with Saybolt Viscometer 6.3. Thermometer SupportOne suitable design is shown in Figure 3. Note: All dimensions are in millimeters (inches). Figure 3Thermometer Support SilverSoldered1/4 in. NPSPipe Cap4.8 (0.19) ID6.4
18、 (0.25)OD127 (5.0)38 (1.5)3.2 (0.13) OD1.6 (0.06) ID15.9 (0.63)17.5 (0.69)7.9 (0.31)76 (3.0)15.9(0.63)4.8 (0.19)9.5 (0.37) 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-2a T 72-5 AASHTO 6.4. Saybolt
19、 Viscosity Thermometersas listed in Table 1, for reading the temperature of the sample. Each thermometer shall conform to the requirements listed in ASTM E1 for that ASTM Thermometer Number. Table 1ASTM Saybolt Viscosity Thermometers Standard Test Temperature, C (F) ASTM Thermometer Number Thermomet
20、er Range, C (F) Subdivisions, C (F) 21.1 (70) 17C (17F) 19 to 27 (66 to 80) 0.1 (0.2) 25.0 (77) 17C (17F) 19 to 27 (66 to 80) 0.1 (0.2) 37.8 (100) 18C (18F) 34 to 42 (94 to 108) 0.1 (0.2) 50.0 (122) 19C (19F) 49 to 57 (120 to 134) 0.1 (0.2) 54.4 (130) 19C (19F) 49 to 57 (120 to 134) 0.1 (0.2) 60.0 (
21、140) 20C (20F) 57 to 65 (134 to 148) 0.1 (0.2) 82.2 (180) 21C (21F) 79 to 87 (174 to 188) 0.1 (0.2) 98.9 (210) 22C (22F) 95 to 103 (204 to 218) 0.1 (0.2) 6.5. Bath ThermometersSaybolt viscosity thermometers, or any other temperature-indicating devices of equivalent accuracy. 6.6. Filter Funnelas sho
22、wn in Figure 4, equipped with interchangeable 0.850-mm (No. 20), 0.150-mm (No. 100), and 0.075-mm (No. 200) wire-cloth inserts meeting the requirements of ASTM E11 with respect to the wire cloth. Filter funnels of a suitable alternate design may be used. Note: All dimensions are in millimeters (inch
23、es). Figure 4Filter Funnel for Use with Saybolt Viscometer AWireClothAWireClothSpringClip1.6 (0.06)95 (3.75)6013(0.5)23(0.91)6.4 (0.25)51 (2.0)22(0.87) 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-
24、2a T 72-6 AASHTO 6.7. Receiving Flaskas shown in Figure 5. Note: All dimensions are in millimeters (inches). Figure 5Receiving Flask 6.8. Timergraduated in tenths of a second and accurate to 0.1 percent when tested over a 60-min interval. Electric timers are acceptable if operated on a controlled-fr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOT722010STANDARDMETHODOFTESTFORSAYBOLTVISCOSITYPDF

链接地址:http://www.mydoc123.com/p-418347.html