AASHTO M 259-2017 Standard Specification for Precast Reinforced Concrete Box Sections for Culverts Storm Drains and Sewers.pdf
《AASHTO M 259-2017 Standard Specification for Precast Reinforced Concrete Box Sections for Culverts Storm Drains and Sewers.pdf》由会员分享,可在线阅读,更多相关《AASHTO M 259-2017 Standard Specification for Precast Reinforced Concrete Box Sections for Culverts Storm Drains and Sewers.pdf(29页珍藏版)》请在麦多课文档分享上搜索。
1、Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers AASHTO Designation: M 259-171Technical Section: 4a, Concrete Drainage Structures Release: Group 2 (June 2017) ASTM Designation: C789-95a American Association of State Highway and Transportation
2、 Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001TS-4a M 259-1 AASHTO Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers AASHTO Designation: M 259-171Technical Section: 4a, Concrete Drainage Structures Release: Group 2
3、(June 2017) ASTM Designation: C789-95a 1. SCOPE 1.1. This specification covers single-cell precast reinforced concrete box sections intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes, and sewage. 1.2. A complete metric companion to M 259 has
4、 been developedM 259M; therefore, no metric equivalents are presented in this specification. Note 1This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in the Appendixes. The succ
5、essful performance of this product depends on the proper selection of the box section, bedding, and backfill, and care that the installation conforms to the construction specifications. The owner of the precast reinforced concrete box sections specified herein is cautioned that the loading condition
6、s and the field requirements must properly correlate with the box section specified and that inspection at the construction site must be provided. Note 2M 273 is to be used for box sections with less than 2 ft of cover subjected to highway loading. Note 3If load-and-resistance factor design (LRFD) i
7、s required, then use ASTM C1577. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: M 6, Fine Aggregate for Hydraulic Cement Concrete M 32M/M 32, Steel Wire, Plain, for Concrete Reinforcement M 55M/M 55, Steel Welded Wire Reinforcement, Plain, for Concrete M 80, Coarse Aggregate for Hydraulic Cement Con
8、crete M 85, Portland Cement M 154M/M 154, Air-Entraining Admixtures for Concrete M 157, Ready-Mixed Concrete M 221M/M 221, Steel Welded Wire Reinforcement, Deformed, for Concrete M 225M/M 225, Steel Wire, Deformed, for Concrete Reinforcement M 240M/M 240, Blended Hydraulic Cement M 262, Concrete Pip
9、e and Related Products 2017 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 259-2 AASHTO M 273, Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers with Less Than 2 ft of C
10、over Subjected to Highway Loadings M 295, Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete T 280, Concrete Pipe, Manhole Sections, or Tile Standard Specifications for Highway Bridges 2.2. ASTM Standards: C309-03, Standard Specification for Liquid Membrane-Forming Compounds for C
11、uring Concrete C1116/C1116M, Standard Specification for Fiber-Reinforced Concrete C1577, Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers Designed According to AASHTO LRFD 2.3. ACI Code: ACI 318-71, Building Code 3. TERMINOLOGY 3.1
12、. DefinitionsFor definitions of terms relating to concrete pipe, see M 262. 4. TYPES 4.1. Precast reinforced concrete box sections manufactured in accordance with this specification shall be of three types identified in Tables 1, 2, and 3, and shall be designated by type, span, rise, and design eart
13、h cover. 2017 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 259-3 AASHTO Table 1Design Requirements for Precast Concrete Box Sections under Earth Dead and HS20 Live Load Conditionsa Design Earth Cov
14、er, ftaM, Min in. Circumferential Reinforcement AreasbDesign Earth Cover, ftaM, Min in. Circumferential Reinforcement AreasbAs1As2As3As4As1As2As3As43 ft by 2 ft by 4 in.c12 18 0.12d0.19 0.19 0.12d2 17 0.19 0.20 0.21 0.10d14 18 0.12d0.21 0.21 0.12d3 15 0.10 0.11 0.11 0.10d16 18 0.12d0.23 0.24 0.12d4
15、to 8 15 0.10d0.10d0.10d0.10d18 17 0.14 0.25 0.26 0.12d10 15 0.10d0.11 0.11 0.10d5 ft by 3 ft by 6 in.c12 14 0.10d0.13 0.13 0.10d2 23 0.26 0.28 0.23 0.14d14 14 0.11 0.14 0.14 0.10d3 21 0.17 0.18 0.18 0.14d16 14 0.12 0.16 0.16 0.10d4 21 0.14d0.15 0.15 0.14d18 14 0.13 0.17 0.18 0.10d5 20 0.14d0.14d0.15
16、 0.14d20 14 0.14 0.19 0.19 0.10d6 20 0.14d0.15 0.15 0.14d3 ft by 3 ft by 4 in.c8 20 0.14d0.16 0.16 0.14d2 27 0.15 0.24 0.25 0.10d10 20 0.15 0.18 0.19 0.14d3 20 0.10 0.13 0.14 0.10d12 20 0.17 0.20 0.21 0.14d4 to 6 17 0.10d0.10d0.10d0.10d14 20 0.19 0.23 0.23 0.14d8 15 0.10d0.11 0.11 0.10d16 19 0.21 0.
17、26 0.26 0.14d10 15 0.10d0.12 0.13 0.10d18 19 0.23 0.28 0.29 0.14d12 15 0.10d0.14 0.14 0.10d5 ft by 4 ft by 6 in.c14 15 0.10d0.15 0.16 0.10d2 28 0.23 0.32 0.27 0.14d16 15 0.10d0.17 0.18 0.10d3 23 0.15 0.20 0.21 0.14d18 15 0.10d0.19 0.19 0.10d4 to 6 22 0.14d0.16 0.17 0.14d20 15 0.11 0.21 0.21 0.10d8 2
18、0 0.14d0.17 0.18 0.14d4 ft by 2 ft by 5 in.c10 20 0.14d0.20 0.21 0.14d2 19 0.26 0.22 0.20 0.12d12 20 0.14d0.22 0.23 0.14d3 18 0.15 0.13 0.13 0.12d14 20 0.16 0.25 0.26 0.14d4 to 8 18 0.12d0.12d0.12d0.12d16 19 0.18 0.28 0.29 0.14d10 17 0.13 0.13 0.14 0.12d18 19 0.20 0.31 0.31 0.14d12 17 0.15 0.15 0.15
19、 0.12d5 ft by 5 ft by 6 in.c14 17 0.17 0.17 0.17 0.12d2 41 0.20 0.35 0.29 0.14d16 17 0.19 0.19 0.19 0.12d3 29 0.14d0.22 0.23 0.14d18 17 0.21 0.21 0.21 0.12d4 25 0.14d0.18 0.19 0.14d4 ft by 3 ft by 5 in.c5 24 0.14d0.17 0.18 0.14d2 22 0.21 0.27 0.24 0.12d6 22 0.14d0.17 0.18 0.14d3 19 0.13 0.16 0.16 0.
20、12d8 22 0.14d0.18 0.19 0.14d4 18 0.12d0.13 0.13 0.12d10 21 0.14d0.21 0.22 0.14d5 18 0.12d0.12d0.13 0.12d12 21 0.14d0.23 0.24 0.14d6 17 0.12d0.12d0.13 0.12d14 21 0.14d0.26 0.27 0.14d8 17 0.12d0.14 0.14 0.12d16 21 0.16 029 0.30 0.14d10 17 0.12d0.15 0.16 0.12d18 20 0.17 0.32 0.33 0.14d12 17 0.12d0.17 0
21、.18 0.12d6 ft by 3 ft by 7 in.c14 17 0.13 0.20 0.20 0.12d2 29 0.30 0.29 0.22 0.17d16 17 0.15 0.22 0.22 0.12d3 24 0.21 0.19 0.18 0.17d18 17 0.16 0.24 0.24 0.12d4 24 0.18 0.17d0.17d0.17d4 ft by 4 ft by 5 in.c5 24 0.17d0.17d0.17d0.17d2 34 0.18 0.30 0.28 0.12d6 23 0.17d0.17d0.17d0.17d3 24 0.12d0.18 0.18
22、 0.12d8 23 0.17d0.18 0.18 0.17d4 21 0.12d0.14 0.15 0.12d10 23 0.20 0.20 0.21 0.17d5 20 0.12d0.13 0.14 0.12d12 23 0.23 0.23 0.24 0.17d6 19 0.12d0.14 0.14 0.12d14 23 0.26 0.26 0.26 0.17d8 18 0.12d0.15 0.15 0.12d16 23 0.28 029 0.29 0.17d10 18 0.12d0.16 0.17 0.12d18 23 0.31 0.32 0.32 0.17dContinued on n
23、ext page. 2017 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 259-4 AASHTO Table 1Design Requirements for Precast Concrete Box Sections under Earth Dead and HS20 Live Load Conditionsa(Continued) Desi
24、gn Earth Cover, ftaM, Min in. Circumferential Reinforcement AreasbDesign Earth Cover, ftaM, Min in. Circumferential Reinforcement AreasbAs1As2As3As4As1As2As3As46 ft by 4 ft by 7 in.c14 25 0.25 0.35 0.36 0.19d2 28 0.26 0.33 0.26 0.17d16 25 0.27 0.38 0.40 0.19d3 25 0.18 0.22 0.21 0.17d18 25 0.30 0.42
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOM2592017STANDARDSPECIFICATIONFORPRECASTREINFORCEDCONCRETEBOXSECTIONSFORCULVERTSSTORMDRAINSANDSEWERSPDF

链接地址:http://www.mydoc123.com/p-417747.html