IEEE 1895-2014 en Below-Grade Inspection and Assessment of Corrosion on Steel Transmission Distribution and Substation Structures《在钢传输、配电和变电结构的腐蚀等级方面的不合格检测和评估 n.pdf
《IEEE 1895-2014 en Below-Grade Inspection and Assessment of Corrosion on Steel Transmission Distribution and Substation Structures《在钢传输、配电和变电结构的腐蚀等级方面的不合格检测和评估 n.pdf》由会员分享,可在线阅读,更多相关《IEEE 1895-2014 en Below-Grade Inspection and Assessment of Corrosion on Steel Transmission Distribution and Substation Structures《在钢传输、配电和变电结构的腐蚀等级方面的不合格检测和评估 n.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、 NACESP0415-2015/IEEEStd1895-2014NACE SP0415-2015/IEEE Std 1895-2014 NACE International and IEEE Joint Standard Practice for Below-Grade Inspection and Assessment of Corrosion on Steel Transmission, Distribution, and Substation Structures Approved 2014-12-10 (IEEE) 2015-01-28 (NACE) NACE Internation
2、al 15835 Park Ten Place Houston, Texas 77084-5145 +1 281-228-6200 IEEE 3 Park Ave., 17th Floor New York, NY 10016-5997 +1 212-419-7900 2015, NACE International and Institute of Electrical and Electronics Engineers (IEEE) NACE SP0415/IEEE Std 1895-2014 NACE SP0415/IEEE Std 1895-2014 NACE Internationa
3、l and IEEE NACE International and IEEE Joint Standard Practice for Below-Grade Inspection and Assessment of Corrosion on Steel Transmission, Distribution, and Substation Structures Administered by NACE Specific Technology Group (STG) 41, “Electric Utility Generation, Transmission, and Distribution”
4、Approved 2015-01-28 NACE Board of Directors Sponsor Transmission and Distribution (PE/T (2) excavate and inspect the selected structures; (3) categorize the condition of structures based on corrosion degradation; (4) prioritize structures requiring additional inspection based on those findings; and
5、(5) help identify next steps as required. The standard is limited to the inspection and assessment of steel transmission towers, poles, and substation structures, to include galvanized, self-weathering, and painted mild steel structures, as well as other similar structures. Key words: below-grade co
6、rrosion, below-grade steel, carbon steel, corrosion control, corrosion, data collection, electric transmission, galvanized steel, IEEE 1895, inspection, SP0415, substation NACE International 15835 Park Ten Place Houston, Texas 77084-5145 +1 281-228-6200 IEEE 3 Park Ave., 17th Floor New York, NY 1001
7、6-5997 +1 212-419-7900 Copyright 2015 by NACE International and Institute of Electrical and Electronics Engineers (IEEE) NACE PDF/PRINT: ISBN 1-57590-311-3 Item No. 21189SG/21189 IEEE PDF: ISBN 978-0-7381-9444-8 STD20050 No part of this publication may be reproduced in any form, in an electronic ret
8、rieval system or otherwise, without the prior written permission of the publisher. NACE SP0415/IEEE Std 1895-2014 NACE International and IEEE This NACE International/Institute of Electrical and Electronics Engineers (IEEE) standard represents a consensus of those individual members who have reviewed
9、 this document, its scope, and provisions. Its acceptance does not in any respect preclude anyone, whether he or she has adopted the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not in conformance with this standard. Nothing contained in thi
10、s NACE/IEEE standard is to be construed as granting any right, by implication or otherwise, to manufacture, sell, or use in connection with any method, apparatus, or product covered by letters patent, or as indemnifying or protecting anyone against liability for infringement of letters patent. This
11、standard represents minimum requirements and should in no way be interpreted as a restriction on the use of better procedures or materials. Neither is this standard intended to apply in all cases relating to the subject. Unpredictable circumstances may negate the usefulness of this standard in speci
12、fic instances. NACE and IEEE assumes no responsibility for the interpretation or use of this standard by other parties and accepts responsibility for only those official NACE and IEEE interpretations issued by NACE and IEEE in accordance with their governing procedures and policies which preclude th
13、e issuance of interpretations by individual volunteers. Users of this NACE/IEEE standard are responsible for reviewing appropriate health, safety, environmental, and regulatory documents and for determining their applicability in relation to this standard prior to its use. This NACE/IEEE standard ma
14、y not necessarily address all potential health and safety problems or environmental hazards associated with the use of materials, equipment, and/or operations detailed or referred to within this standard. Users of this NACE/IEEE standard are also responsible for establishing appropriate health, safe
15、ty, and environmental protection practices, in consultation with appropriate regulatory authorities if necessary, to achieve compliance with any existing applicable regulatory requirements prior to the use of this standard. CAUTIONARY NOTICE: NACE/IEEE standards are subject to periodic review, and m
16、ay be revised or withdrawn at any time in accordance with NACE/IEEE technical committee procedures. NACE and IEEE require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of initial publication and subsequently from the date of each reaffirma
17、tion or revision. The user is cautioned to obtain the latest edition. Purchasers may receive current information on all standards and other publications by contacting the organizations at the addresses below: 2015, NACE International and Institute of Electrical and Electronics Engineers (IEEE) IMPOR
18、TANT NOTICE: This standard is not intended to ensure safety, security, health, or environmental protection in all circumstances. Implementers of the standard are responsible for determining appropriate safety, security, environmental, and health practices or regulatory requirements. This IEEE docume
19、nt is made available for use subject to important notices and legal disclaimers. These notices and disclaimers appear in all publications containing this document and may be found under the heading “Important Notice” or “Important Notices and Disclaimers Concerning IEEE Documents.” They can also be
20、obtained on request from IEEE or viewed at http:/standards.ieee.org/IPR/disclaimers.html. NACE International 15835 Park Ten Place Houston, TX 77084-5145, USA +1 281-228-6200 Secretary, IEEE-SA Standards Board 445 Hoes Lane Piscataway, NJ 08854 USA NACE SP0415/IEEE Std 1895-2014 NACE International an
21、d IEEE i _ Foreword There are an estimated 900,000 electric utility steel transmission and distribution structures in North America alone. The majority of these structures were installed between 1950 and 1990. These structures are now an average of 45 years in age. The age of these structures dictat
22、es an inspection and assessment procedure to determine the level of corrosion affecting the buried portions of this important segment of our infrastructure. While the condition of the above-grade portions of these structures is relatively easy to visually assess, the buried or below-grade sections a
23、re often subject to a more corrosive environment and are not easily accessible for visual inspection. Before the publication of this standard, no industry practice existed to help electric utilities determine a prioritized listing of structures to be inspected or that described an inspection and ass
24、essment procedure to evaluate below-grade corrosion problems. This standard is intended for use by electric utility personnel, contractors, inspectors, and those interested in the impact of corrosion on the below-grade sections of transmission, distribution, and substation steel structures. This sta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEE18952014ENBELOWGRADEINSPECTIONANDASSESSMENTOFCORROSIONONSTEELTRANSMISSIONDISTRIBUTIONANDSUBSTATIONSTRUCTURES

链接地址:http://www.mydoc123.com/p-1248528.html