UL 790 CRD-2013 Section Paragraph Reference 4 4 1 Subject Preparation Application of Test Samples (Edition 8 April 22 2004)《屋面覆盖材料耐火性的标准试验 节 段参考 4 4 1主题 试样的制备 应用 (第八版 2004年4月22日).pdf
《UL 790 CRD-2013 Section Paragraph Reference 4 4 1 Subject Preparation Application of Test Samples (Edition 8 April 22 2004)《屋面覆盖材料耐火性的标准试验 节 段参考 4 4 1主题 试样的制备 应用 (第八版 2004年4月22日).pdf》由会员分享,可在线阅读,更多相关《UL 790 CRD-2013 Section Paragraph Reference 4 4 1 Subject Preparation Application of Test Samples (Edition 8 April 22 2004)《屋面覆盖材料耐火性的标准试验 节 段参考 4 4 1主题 试样的制备 应用 (第八版 2004年4月22日).pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): TFWX, TFXX, TGFUStandard Number: UL 790Standard Title: Standard Test Methods for Fire Tests of Roof CoveringsEdition Date: April 22, 2004Edition Number: 8Sec
3、tion / Paragraph Reference: 4.4.1Subject: Preparation / Application of Test SamplesDECISION:4.4.1 The prepared roof covering material to be tested is to be applied, in accordance with the testsponsors instructions, to the applicable number of test decks as specified in Table 3.1. The material is toe
4、xtend to, and be flush with, the edges of the deck on the sides and top. At the leading edge, the materialis to be positioned except for a 1 inch (25.4 mm) overhang at the leading edge, such that there is minimumcoverage, or a minimum number of layers, over the horizontal deck joints. For mechanical
5、ly attached andfully adhered single-ply membrane roof covering systems it is not prohibited to pull the membrane tautover the edges of the assembly to fit snugly against the deck and secure it to the wood supports of thetest deck. The use of a 1-in (25-mm) width metal batten strip or wire fastened o
6、n top of and along eachside edge is not prohibited for mechanically attached single-ply membrane roof covering systems.RATIONALE FOR DECISION:The intent of Section 4.4.1 on Preparation and Application of the samples in UL 790 is to examineproducts in such a manner that there is minimum coverage, or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL790CRD2013SECTIONPARAGRAPHREFERENCE441SUBJECTPREPARATIONAPPLICATIONOFTESTSAMPLESEDITION8APRIL222004

链接地址:http://www.mydoc123.com/p-1068929.html